Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (16)
- Deutsch (4)
- Mehrsprachig (1)
Schlagworte
- Additive manufacturing (5)
- Magnesium (5)
- Reproducibility (3)
- AlSi10Mg (2)
- Beschichtung (2)
- Biodegradation (2)
- Corrosion (2)
- Elektrochemisches Rauschen (2)
- Korrosion (2)
- Laser powder bed fusion (2)
Organisationseinheit der BAM
- 6 Materialchemie (3)
- 9 Komponentensicherheit (3)
- 9.6 Additive Fertigung metallischer Komponenten (3)
- 5 Werkstofftechnik (2)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.5 Proteinanalytik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 6.7 Materialsynthese und Design (1)
High Speed, High Resolution imaging spectrometers based on pnCCDs for XRF and XRD applications
(2016)
For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light sources in large accelerator facilities as well as with laboratory light sources or with X-rays from celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF) measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of structure and dynamics of matter.
When it comes to higher accuracies, new technologies and real applications in additive manufacturing, there is one topic which cannot be avoided: The material response on the chosen processing parameters and its agreement and correspondence with literature data of the wrought material grade counterpart. In industrial Additive Manufacturing (AM) standards in terms of printing parameters, protection gas atmospheres or powder handling instructions are not obligatory. Therefore, the question must be answered whether the AM process is reproducible and reliable over different printing companies. This was the motivation to realize a round robin test between 8 European printing companies and academic partners. The consortium had printed and tested fatigue and tensile testing bars under plant-specific conditions. A commonly used cast aluminum alloy, AlSi10Mg, was chosen as test material for the PBF-LB/M process. Differences of the results between the partners and the scatter itself were discussed in detail.
When it comes to higher accuracies, new technologies and real applications in additive manufacturing, there is one topic which cannot be avoided: The material response on the chosen processing parameters and its agreement and correspondence with literature data of the wrought material grade counterpart. In industrial Additive Manufacturing (AM) standards in terms of printing parameters, protection gas atmospheres or powder handling instructions are not obligatory. Therefore, the question must be answered whether the AM process is reproducible and reliable over different printing companies. This was the motivation to realize a round robin test between 8 European printing companies and academic partners. The consortium had printed and tested fatigue and tensile testing bars under plant-specific conditions. A commonly used cast aluminum alloy, AlSi10Mg, was chosen as test material for the PBF-LB/M process. Differences of the results between the partners and the scatter itself were discussed in detail.
The round robin test investigated the reliability users can expect for AlSi10Mg additive manufactured specimens by laser powder bed fusion through examining powder quality, process parameter, microstructure defects, strength and fatigue. Besides for one outlier, expected static material properties could be found. Optical microstructure inspection was beneficial to determine true porosity and porosity types to explain the occurring scatter in properties. Fractographic analyses reveal that the fatigue crack propagation starts at the rough as-built surface for all specimens. Statistical analysis of the scatter in fatigue using statistical derived safety factors concludes that at a stress of 36.87 MPa the fatigue limit of 107 cycles could be reached for all specimen with a survival probability of 99.999 %.
The degradation behaviour of an Mg-1Ca alloy is investigated in vitro to figure out the possibilities of influencing the degradation behaviour of such an alloy by applying heat treatment as well as the use of a coating system based on plasma-chemical oxidation. It is shown that an optimised solution annealing (T4-heat treatment) can reduce the degradation rate while an additional ageing between 240 and 300 °C (T6-heat treatment) increases it. A coating generated by plasma-chemical oxidation reduces the degradation rate in the immersion test. Its effect is depending on the former heat treatment of the Mg-1Ca alloy as well as on the parameter during plasma-chemical oxidation.
With a growing percentage of elderly people in the population and, correspondingly, an increasing rate of fractures of the proximal femur, the question how to stabilize medial femoral-neck fractures is gaining increasing importance. Especially in Hungary and Scandinavian countries, femoral-head-preserving surgery is advocated. However, the main problems of this procedure are re-dislocation and necrosis of the femoral head. Encouraged by two theoretical mathematical considerations, a biomechanical experiment was performed to investigate two different methods of screw fixation of medial femoral-neck fractures. The results showed that a head-preserving internal fixation with two cranial screws and a three-point supported screw at the bottom of the neck had distinct biomechanical advantages compared to conventional screw fixation. This has encouraged us to more frequently perform this minimally invasive and head-preserving surgery in Pauwels I and II medial fractures of the femoral head.
The main problem limiting the application of magnesium alloys as biodegradable implant material is its high degradation rate. In order to slow down the corrosion rate an extrusion process and specific coating systems based on plasma-chemical oxidation (PCO) and organic dip coating with poly(ʟ-lactid-co-caprolacton) (PLLC) were applied on Mg–1Ca magnesium alloy. The additional PLLC coating is used to delay the start of substrate corrosion, while the purpose of the PCO coating is to decrease the substrate corrosion rate. The corrosion behaviour was investigated in synthetic body fluid (SBF) through measurement of the hydrogen evolution rate in long term tests and polarisation and electrochemical noise measurements in short term tests. The results showed significant differences between the cast and extruded alloys and a decrease of the corrosion rate due to corrosion product formation. The combination of both coating systems resulted in a significant delay of metal substrate corrosion and all coating systems showed good correlation between short and long term tests. The combination of the three investigation methods provides the possibility to gain more information about the degradation behaviour and break down of protective coatings.
Die Magnesiumlegierung Mg-Cal besitzt als potentielles bioabsorbierbares Implantatmaterial die Möglichkeit, vollständig vom menschlichen Körper absorbiert zu werden. Die mechanischen Kennwerte dieser Legierung liegen im Bereich des menschlichen Knochens und beide Legierungselemente (Mg, Ca) sind essentielle Spurenelemente im menschlichen Organismus.
Der limitierende Faktor für den Einsatz ist die hohe Degradationsrate dieser Legierung. Um die Degradationsgeschwindigkeit zu verringern, wurden zwei Beschichtungssysteme auf Grundlage der Plasmachemischen Oxidation (PCO) und organischer Beschichtung erzeugt und untersucht. Das Korrosionsverhalten dieser Schichtsysteme wurde dabei mit dem Elektrochemischen Rauschen analysiert. Zusätzlich wurde der Einfluss von Wasserstoffentwicklung und eines ansteigenden pHWert auf die Zelltoxizität untersucht. Die Ergebnisse zeigen, dass eine Kombination von beiden Schichtsystemen zu einem viel versprechenden Degradationsverhalten führt.
As bio-absorbable implant material the magnesium alloy Mg-1Ca is able to degrade in-vivo. The mechanical properties of this alloy are similar to those of human bone; both Mg and Ca are essential elements in human body. The main problem is the high corrosion rate of this alloy. Two coating systems based on plasma-chemical oxidation and an organic dip coating are applied onto MgCa1.0 magnesium alloy in order to slow down the corrosion rate. The corrosion behaviour of the coated alloys was investigated with electrochemical noise measurements. The influence of hydrogen evolution and increasing pH-value on the cytotoxicity was examined. The results of these investigations suggest that a combination of both coating systems leads to promising degradation properties.
Studienziel: Bei der zunehmenden Überalterung der Bevölkerung und der zunehmenden Inzidenz an hüftgelenknahen Oberschenkelfrakturen nimmt die Frage der Versorgung der medialen Schenkelhalsfraktur eine zunehmende Rolle ein. Vor allem aus Ungarn und den skandinavischen Ländern wird die kopferhaltende Therapie propagiert. Das Redislozieren dieser Frakturen und die Hüftkopfnekrose sind jedoch dagegenstehende Probleme. Methode: Ermutigt durch zwei theoretische mathematische Überlegungen wurden in einem biomechanischen Experiment zwei verschiedene Möglichkeiten der Verschraubung der medialen Schenkelhalsfraktur erprobt. Ergebnisse: Als Ergebnis zeigte sich, dass eine kopferhaltende Versorgung mit 2 kranial liegenden Schrauben und einer dreipunktabgestützten Schraube am Adam'schen Bogen deutliche biomechanische Vorteile hat gegenüber der herkömmlichen Verschraubung. Schlussfolgerung: Dies ermutigt uns, zunehmend die minimalinvasive und kopferhaltende Versorgung der medialen Schenkelhalsfraktur insbesondere bei Pauwels-I- und II-Verletzungen einzusetzen.