The arrangement of the measuring sensors allowed the
capture of air flow induced temperatures and material
temperatures on various points of the cylinder body. Four
significant temperature levels could be observed: Inside the cylinder (far from the wall, close to the wall), inside the aluminium liner and outer surface. Figure 5 shows the temperature distribution after a regular filling process with a filling time of ten minutes. The temperature sensors T1 - T9 are marked with different colors. The corresponding measurement points are shown in Figure 4. Due to the high thermal conductivity of the aluminum liner the induced temperature peaks are quickly derived. A flow-induced exceeding of the maximum approval temperature is not expected. Regarding the safety assessement the results show that the pressure and temperature profilesmustbe taken into account.
Atemluftflaschen aus Faserverbundwerkstoffen werden im Feuerwehrbetrieb hohen thermischen Belastungen ausgesetzt. Der thermisch sichere Bereich dieser Behälter ist jedoch heutzutage noch nicht einschätzbar. Deshalb haben es sich die Bundesanstalt für Materialforschung und -prüfung (BAM) im Austausch mit der Bergischen Universität Wuppertal zur Aufgabe gemacht, die Auswirkungen dieser Betriebslasten zu untersuchen. Die Erkenntnisse dieser Untersuchungsreihe werden genutzt, um einzuschätzen, ob es sicherheitstechnisch notwendig ist, besondere thermische Betriebsbedingungen in normativen Prüfkriterien zu berücksichtigen.
In einem ersten Schritt wurden Typ-III-Atemluftflaschen der Berliner Feuerwehr Umgebungsbedingungen des typischen Belastungsprofils der Brandbekämpfung (130 °C bis 250 °C, 10 Minuten) ausgesetzt, um die Erwärmung des Behältermaterials zu erfassen. Da die Größe der bestrahlten Oberfläche in einem Brandeinsatz nicht bekannt ist, erfolgte zusätzlich eine Variation der Strahlungsexposition. Strömungsprozesse, die in einem Brandeinsatz den Behälter von innen kühlen, wurden in diesem ersten Untersuchungsabschnitt noch nicht betrachtet.
Es konnte gezeigt werden, dass der Aluminium-Liner einer Typ-III-Atemluftflasche einen erheblichen Einfluss auf die Temperaturverteilung im Behältermaterial ausübt. Die hohe Leitfähigkeit des Aluminiums führt bei Verringerung der bestrahlten Behälteroberfläche zu hohen Temperaturgradienten innerhalb der Behälterwand. Die Materialtemperaturen in der Atemluftflasche konnten für das Belastungsprofil der Brandbekämpfung auf ein typisches Temperaturintervall eingegrenzt werden. Die Grenzen liefern Aussagen zur exponierten Behälteroberfläche und liegen zwischen einseitiger und Vollbestrahlung.
Assessment experience on packages loaded with damaged spent nuclear fuel for transport after storage
(2018)
In 2017 the first German package approval certificate was issued for a dual purpose cask (DPC) design with encapsulated damaged spent nuclear fuel. At the Bundesanstalt für Materialforschung und -prüfung (BAM) a comprehensive assessment procedure was carried out with respect to the mechanical and thermal design, the containment design and quality assurance for manufacturing and operation. Main objective of this procedure was to verify the Package Design Safety Report (PDSR) fulfils the requirements according to the IAEA regulations SSR-6.
Until now only standard spent nuclear fuel assemblies were designated for interim storage and transports. Due to nuclear phase out in Germany all other kinds of SNF in particular damaged fuel has to be packed. Therefore specific requirements have to be considered in accordance with international experiences written in IAEA technical reports. In Germany damaged spent nuclear fuel (DSNF) needs a tight encapsulation with special encapsulations and clearly defined properties.
Due to the limited amount of DSNF these encapsulations are designed for storage and transport in existing packages. From the assessment experience it has been seen, corresponding PDSR need an extensively expansion to cover the design of these encapsulations and their influences on the package. Then such well-defined encapsulations can be handled like standard fuel assemblies. The main difference to standard package components is, encapsulations with permanent closure achieve their specified condition not after manufacturing but only during operation after loading and closing.
Thus specific handling instruction and test procedures are necessary especially for welding, where BAM is able to survey the quality of this first part of operation.
Das Einsatzspektrum von den besonders leichten Druckbehältern aus Faserverbund-werkstoffen erweitert sich kontinuierlich. Dies führt dazu, dass mit der erweiterten Verwendung auch die thermisch zulässigen Einsatzgrenzen dieser Behälter ausgeschöpft und sogar teilweise überschritten werden. So können bspw. Atemluftflaschen im Brandeinsatz der Feuerwehr an der Behälteroberfläche derart hohen Umgebungstemperaturen ausgesetzt werden, dass die zulässige Höchsttemperatur von 65 °C deutlich überschritten wird.
Durch experimentelle Temperaturversuche an Typ-III-Atemluftflaschen mit einem Innenbehälter aus Aluminium konnte gezeigt werden, dass bei der Brandbekämpfung die untersuchten Atemluftflaschen lokal über das in der Zulassung abgeprüfte Temperaturspektrum erhitzt werden. Der Glasübergangsbereich des Faserverbundwerkstoffs wird partiell um bis zu 95 °C überschritten. Um die reale Sicherheit der Atemluftflasche bewerten zu können, wurde ein analytisches Hybridbehältermodell entwickelt, das die Beanspruchungen mit validierten Materialtemperaturverläufen berechnet. Mit der Einbindung von Schädigungsansätzen konnte ein bisher nicht hinreichend beachtetes thermisches Degradationsverhalten in den Berechnungen berücksichtigt werden. Zudem wurden insgesamt 90 altersbedingt ausgesonderte Feuerwehr-Atemluftflaschen zerstörend geprüft, um nähere Erkenntnisse über den Sicherheitszustand am Ende der Lebenszeit zu erhalten.
In diesem Kolloquium werden Forschungsergebnisse vorgestellt, die im Rahmen einer Promotionsarbeit die Auswirkungen dieser erhöhten thermischen Betriebslasten auf eine Typ-III-Atemluftflasche mit einem Innenbehälter aus Aluminium darstellen und bewerten.
Typical transport packages used in Germany are equipped with encapsulated wooden impact limiting devices. We would like to present the current status regarding the development of a Finite Element (FE) material model for the crush of wood for the FE-code LS-DYNA. The crush of is a phenomenon governed by macroscopic fracture. Here, we would like to reproduce fracture and failure mechanisms over the continuous volume. In a first step we altered an existing LS-DYNA material model for foams, which considers an ellipse shaped yield surface. For the use for longitudinal compression of wood, we modified the existing material model to consider the deviatoric strain for the evolution of the yield surface as well. This is in accordance with the results of crush tests with spruce wood specimens, where the crushing deformation was rather deviatoric for uniaxial stress states and rather volumetric for multiaxial stress states We rate the basic idea of this approach to be reasonable, though other problems exist regarding the shape of the yield surface and the assumption of isotropic material properties. Therefore we developed a new transversal isotropic material model with two main directions, which considers different yield curves according to the multiaxiality of the stress state via a multi-surface yield criterion and a non-associated flow rule. The results show the ability to reproduce the basic strength characteristics of spruce wood. Nevertheless, problems with regularization etc. show that additional investigations are necessary.
Atemluftflaschen aus Faserverbundwerkstoffen werden im Feuerwehrbetrieb hohen thermischen Belastungen ausgesetzt. Der thermisch sichere Bereich dieser Behälter ist jedoch heutzutage noch nicht einschätzbar. Deshalb haben es sich die Bundesanstalt für Materialforschung und -prüfung (BAM) im Austausch mit der Bergischen Universität Wuppertal zur Aufgabe gemacht, die Auswirkungen dieser Betriebslasten zu untersuchen.