Filtern
Erscheinungsjahr
- 2021 (13) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (10)
- Vortrag (2)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- Fluorescence (4)
- Core-shell particles (3)
- Electron microscopy (2)
- Image processing (2)
- Roughness (2)
- Schnelltests (2)
- Air quality (1)
- Antibiotics (1)
- Antikörper (1)
- Aptamere (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (2)
Reported here is the production of molecularly imprinted polymer (MIP) films, integrating a fluorescent moiety that serves as both an element for template interaction and signalling, for the thermal and optical detection of the beta-lactam antibiotic nafcillin. Fluorescein methacrylate (FluMa) was synthesized and introduced during the molecular imprinting process as the sole monomer and in a 1 : 1 mixture with methacrylic acid (MAA), allowing to draw first conclusions on the MIP formation potential of such a rather large and rigid monomer. At first, MIP microparticles containing FluMa were prepared by free radical polymerisation. Optical batch rebinding experiments revealed that FluMa can act as a functional monomer for selective detection of nafcillin; however, the addition of MAA as co-monomer significantly improved performance. Subsequently, thin MIP films containing FluMa were deposited onto functionalised glass slides and the influence of porogen, drying time, and monomer composition was studied. These MIP-functionalised glass electrodes were mounted into a customised 3D-printed flow cell, where changes in the liquid were either evaluated with a thermal device or using fluorescence bright field microscopy. Thermal analysis demonstrated that multiple MIP layers enhanced sensor specificity, with detection in the environmentally relevant range. The fluorescence bright field microscope investigations validated these results, showing an increase in the fluorescence intensity upon exposure of the MIP-functionalised glass slides to nafcillin solutions. These are promising results for developing a portable sensor device that can be deployed for antibiotics outside of a dedicated laboratory environment, especially if sensor design and fluorophore architecture are optimised.
Die Kombination aus elektrogenerierter Chemilumineszenz (ECL) und Aptamer-gesteuerter Indikatorfreisetzung (gAID) aus magnetischen mesoporösen Silica-Nanopartikeln, die in mit Poly(ethylenglycol) und N-(3-Triethoxysilylpropyl) diethanolamin funktionalisiertes Glasfaserpapier eingebettet sind, ermöglichte die Entwicklung eines Schnelltests, mit dem sich Penicillin direkt in verdünnter Milch bis auf 50 +/- 9 ppt in <5 min nachweisen lässt. Die kovalente Bindung der Aptamer-Kappe an das Siliciumdioxid-Gerüst ermöglichte den Verschluss der Poren durch nicht-kovalente elektrostatische Wechselwirkungen mit Oberflächen-Aminogruppen. Die Bindung von Penicillin führte zu einer Faltung des Aptamers, wodurch der zuvor in das Material geladene ECL-Reporter Ru(bpy)32+ freigesetzt wurde und nach lateralem Fluss von einer Smartphone-Kamera nach elektrochemischer Anregung mit einer in einen 3D-gedruckten Halter eingesetzten Siebdruckelektrode detektiert wird. Der Ansatz ist einfach, generisch und bietet Vorteile hinsichtlich Empfindlichkeit, Messunsicherheit und Robustheit gegenüber konventioneller Fluoreszenz- oder elektrochemischer Detektion, insbesondere für Point-of-Need-Analysen anspruchsvoller Matrices und Analyten im Ultraspurenbereich.
The reversible analyte-induced switching between a colourless leuco form of a dye and its coloured all-π-conjugated form is one of the oldest concepts in probe- or indicator-based optical analysis,1 constituting so-called “one-color indicators”.2 In contrast to colour changes in the visible region, for which usually a bond-forming or a non-covalent interaction between a functional group on an indicator and an analyte is responsible, the extraordinarily large shifts of 150–250 nm seen for leuco-to-all-π-conjugated transformation are only possible when the reaction takes place directly at a site that is an intrinsic part of a dye’s π-system; the classic case are triphenylmethane dyes.3 Despite its obvious potential, this approach has not been a very popular area of scientific research for decades, perhaps because it is much more difficult to implement selectivity than by modifying terminal functional groups. However, in recent years, reaction-based fluorescence probes have attracted increasing attention by virtue of their superior sensitivity.4,5
Nowadays, rhodamines and fluoresceins are by far the most prominent groups of reaction-based indicators.5 They are usually switched between a colourless and non-fluorescent and a greenish-yellowish absorbing and yellowish-reddish emitting form. Typically, the coloured and fluorescent form is ionic, while the colourless form is neutral, reactions having mainly be designed to occur at the end groups of the xanthenoid π-system. BODIPY dyes, with their favourable spectroscopic and chemical properties as well as facile wavelength tunability features have only very recently been explored into this direction.6,7 Reaction at the core dipyrrin framework of these dyes led to strong colour and fluorescence modulations with potential applications in materials sciences6 and cell imaging.7 The present contribution will highlight the mechanisms at play and the sensing performance realized so far, and will compare core-reactive approaches to reaction-based signalling that involves π-extension of BODIPYs.8,9
Analytical assays that can be used outside of a dedicated laboratory environment have received unprecedented attention all around the globe during the last one and a half years, in which the world was struggling with and trying to contain the SARS-CoV-2 pandemic. However, besides their current prominence in the field of medical diagnostics, rapid tests and assays have also become increasingly important in other areas ranging from food and feed via security and forensics to environmental management. The advantage is obvious: taking the assay to the sample instead of bringing the sample to the laboratory minimizes the time between first suspicion and first decision taking. Especially today, where mobile communication devices with powerful computing capabilities and onboard cameras are omnipresent, the majority of the global population possesses the basic skills of operating a powerful detector, ready at their fingertips. The stage is thus set for a much broader use of analytical measurements in terms of prognostics and prevention.
Today, however, tests for single parameters are still prevailing, whether it is a SARS-CoV-2 biomarker, the glucose level in blood or the concentration of lead in a water sample. Also, for industrial use, many mobile analytical systems still target a single parameter, and several separate runs or tests have to be used even if one wants to screen for only a small number of key parameters. Current challenges in the field thus lie with the development of low-number multiplexing strategies while allowing for robust, reliable, fast, and user-friendly operation and while still reaching the required sensitivities.
This lecture will give an overview of various generic approaches developed in BAM’s Chemical and Optical Sensing Division over the years to address these challenges. In particular, it will highlight how the combination of supramolecular (bio)chemistry, luminescence detection, hybrid (nano)materials and device miniaturization can result in powerful (bio)analytical assays that can be used at a point-of-need. Selected examples will introduce key aspects of such systems like tailored signaling mechanisms and recognition elements, materials functionalization and device integration, including hybrid mesoporous nanomaterials, gated indicator release systems, molecularly imprinted polymers, microfluidic devices, test strips and smartphone-based analysis.
Mit dem Testsystem zur Probe
(2021)
A particle roughness analysis tool, based on electron microscopy images (SEM and TEM). The influence of various parameters on the calculated roughness was also investigated: the setting of the proper threshold, accelerating voltage, etc. The samples were gradually tilted to extend imaging information of more than only one projection. Furthermore, the measurement uncertainty of the profile roughness of particles associated to various orientations was estimated.
Laser-induced breakdown spectroscopy (LIBS) and principal component analysis (PCA) are frequently used for analytical purposes in research and industry, but they seldom are part of the chemistry Curriculum or laboratory exercises. This case study paper describes the combined application of LIBS and PCA during a research internship for an undergraduate student. The instructional method applied was based on a one-on-one mentorship, in which case the learner was engaged in a Research work. The learning activities included theoretical introductions to the LIBS and PCA methods, numerical simulation, experiments, and data analysis.
The study covered three main topics: analysis of LIBS spectra, application of PCA for clustering, and use of PCA for experimental design. The realization of the study was instructive for all parties involved: from the mentorship point of view, it is concluded that the topics can be covered during an internship or developed into a one semester long research-based module of a chemistry program or a final year project. The student, on the other hand, developed profound technical skills in performing experiments and using PCA software for data analysis.
The aim of this study is to determine the efficiency of loading and release of several zwitterionic, neutral, anionic and cationic dyes into/from mesoporous nanoparticles to find the optimum loading and release conditions for their application in detection protocols. The loading is carried out for MCM-41 type silica supports suspended in phosphate-buffered saline (PBS) buffer (pH 7.4) or in acetonitrile, involving the dyes (rhodamine B chloride, rhodamine 101 chloride, rhodamine 101 perchlorate, rhodamine 101 inner salt, meso-(4-hydroxyphenyl)-boron–dipyrromethene (BODIPY), sulforhodamine B sodium salt and fluorescein 27). As a general trend, rhodamine-based dyes are loaded with higher efficiency, when compared with BODIPY and fluorescein dyes. Between the rhodamine-based dyes, their charge and the solvent in which the loading process is carried out play important roles for the amount of cargo that can be loaded into the materials. The delivery experiments carried out in PBS buffer at pH 7.4 reveal for all the materials that anionic dyes are more efficiently released compared to their neutral or cationic counterparts. The overall best performance is achieved with the negatively charged sulforhodamine B dye in acetonitrile. This material also shows a high delivery degree in PBS buffer.
The combination of electrogenerated chemiluminescence (ECL) and aptamer-gated indicator delivering (gAID) magnetic mesoporous silica nanoparticles embedded into glass fibre paper functionalised with poly(ethyleneglycol) and N-(3-triethoxysilylpropyl)diethanolamine allowed the development of a rapid test that detects penicillin directly in diluted milk down to 50 ± 9 ppt in <5 min. Covalent attachment of the aptamer ‘cap’ to the silica scaffold enabled pore closure through non-covalent electrostatic interactions with surface amino groups, while binding of penicillin led to a folding-up of the aptamer thus releasing the ECL reporter Ru(bpy)32+ previously loaded into the material and letting it be detected after lateral flow by a smartphone camera upon electrochemical excitation with a screen printed electrode inserted into a 3D-printed holder. The approach is simple, generic and presents advantages with respect to sensitivity, measurement uncertainty and robustness compared with conventional fluorescence or electrochemical detection, especially for point-of-need analyses of challenging matrices and analytes at ultra-trace levels.
In the present paper the development of a semi-automated device for long-term monitoring of gaseous ammonia is described. A sensor material was produced that changes its optical properties in the pres-ence of low concentrations of ammonia in air. The implementation into an electronic device enables precise, simple, economic and fast monitoring of low concentrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.