Filtern
Dokumenttyp
- Zeitschriftenartikel (7)
- Beitrag zu einem Tagungsband (3)
- Vortrag (3)
- Posterpräsentation (2)
Schlagworte
- KorroPad (5)
- Corrosion (3)
- Magnesium (3)
- Martensitic stainless steel (3)
- Austenitic stainless steel (2)
- Corrosion resistance (2)
- Electrochemical noise (2)
- Electrochemical potentiodynamic reactivation (2)
- Heat treatment (2)
- Korrosion (2)
- Nichtrostender Stahl (2)
- Pitting corrosion (2)
- Abrasive belt (1)
- Beschichtung (1)
- Biocompatibility (1)
- Biodegradation (1)
- Coatings (1)
- Cutlery (1)
- DL-EPR (1)
- EPR-Test (1)
- Electrochemical methods (1)
- Elektrochemisches Rauschen (1)
- Grinding (1)
- High‐nitrogen steel (1)
- Implantat (1)
- Korrosionsschnelltest (1)
- Magnesium-Calcium (1)
- Mechanical properties (1)
- Passivschicht (1)
- Plasma-Chemical Oxidation (1)
- Plasma-chemical oxidation (1)
- Plasmachemische Oxidation (1)
- Polarisation (1)
- Prüfmethoden (1)
- Quality control (1)
- Qualitätskontrolle (1)
- Schneidwaren (1)
- Stainless steel (1)
- Surface (1)
- Testing methods (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (3)
As bio-absorbable implant material the magnesium alloy Mg-1Ca is able to degrade in-vivo. The mechanical properties of this alloy are similar to those of human bone; both Mg and Ca are essential elements in human body. The main problem is the high corrosion rate of this alloy. Two coating systems based on plasma-chemical oxidation and an organic dip coating are applied onto MgCa1.0 magnesium alloy in order to slow down the corrosion rate. The corrosion behaviour of the coated alloys was investigated with electrochemical noise measurements. The influence of hydrogen evolution and increasing pH-value on the cytotoxicity was examined. The results of these investigations suggest that a combination of both coating systems leads to promising degradation properties.
Die Magnesiumlegierung Mg-Cal besitzt als potentielles bioabsorbierbares Implantatmaterial die Möglichkeit, vollständig vom menschlichen Körper absorbiert zu werden. Die mechanischen Kennwerte dieser Legierung liegen im Bereich des menschlichen Knochens und beide Legierungselemente (Mg, Ca) sind essentielle Spurenelemente im menschlichen Organismus.
Der limitierende Faktor für den Einsatz ist die hohe Degradationsrate dieser Legierung. Um die Degradationsgeschwindigkeit zu verringern, wurden zwei Beschichtungssysteme auf Grundlage der Plasmachemischen Oxidation (PCO) und organischer Beschichtung erzeugt und untersucht. Das Korrosionsverhalten dieser Schichtsysteme wurde dabei mit dem Elektrochemischen Rauschen analysiert. Zusätzlich wurde der Einfluss von Wasserstoffentwicklung und eines ansteigenden pHWert auf die Zelltoxizität untersucht. Die Ergebnisse zeigen, dass eine Kombination von beiden Schichtsystemen zu einem viel versprechenden Degradationsverhalten führt.
Bei der Qualitätsbewertung von Schneidwaren aus nichtrostenden martensitischen Chrom-Stählen stellt die Überprüfung der Korrosionsbeständigkeit ein wichtiges Kriterium dar. Allgemein üblich sind Wechseltauchversuche mit relativ hohem zeitlichem und auswertungsbedingtem Aufwand, die noch dazu zerstörend sind und teilweise fragwürdige Ergebnisse liefern. In den letzten Jahren wurden neue Ansatze der Prüfung geschaffen, die eine nahezu zerstörungsfreie Kurzzeit-Korrosionsprüfung erlauben. Es wird gezeigt, dass mit dem elektrochemischen Rauschen sehr empfindlich Einflüsse des Härtens und der Oberflächenbehandlung auf die Korrosionsbeständigkeit nachgewiesen werden können, wodurch eine schnelle und objektive Qualitätsbewertung innerhalb des Fertigungsprozesses und der Endkontrolle von Produkten möglich ist. Das für die Prüfmethodik ausgenutzte Phänomen des elektrochemischen Rauschens zielt darauf ab, den Beginn der Korrosion empfindlich und schnell zu detektieren, ohne die Prüfbedingungen maßlos zu verschärfen und Produkte damit zu zerstören. Neben der Funktionalität der Prüfung stehen aber auch die Anwenderfreundlichkeit und somit die Akzeptanz bei den Herstellern im Vordergrund. Aus diesem Grund wurde zusätzlich ein Indikatortest (KorroPad) als praxistaugliche Alternative zum elektrochemischen Rauschen angewendet. Die Ergebnisse zeigen eine gute Übereinstimmung beider Methoden und ermöglichen eine effektive betriebliche Qualitätsüberwachung von Schneidwaren.
The main problem limiting the application of magnesium alloys as biodegradable implant material is its high degradation rate. In order to slow down the corrosion rate an extrusion process and specific coating systems based on plasma-chemical oxidation (PCO) and organic dip coating with poly(ʟ-lactid-co-caprolacton) (PLLC) were applied on Mg–1Ca magnesium alloy. The additional PLLC coating is used to delay the start of substrate corrosion, while the purpose of the PCO coating is to decrease the substrate corrosion rate. The corrosion behaviour was investigated in synthetic body fluid (SBF) through measurement of the hydrogen evolution rate in long term tests and polarisation and electrochemical noise measurements in short term tests. The results showed significant differences between the cast and extruded alloys and a decrease of the corrosion rate due to corrosion product formation. The combination of both coating systems resulted in a significant delay of metal substrate corrosion and all coating systems showed good correlation between short and long term tests. The combination of the three investigation methods provides the possibility to gain more information about the degradation behaviour and break down of protective coatings.
Die Qualität von Schneidwaren aus martensitisch nichtrostenden Stählen (MNS) hängt neben ihrer härtebedingten Schneidleistung wesentlich von ihrer Korrosionsbeständigkeit ab, die dauerhaft das hochwertige optische Erscheinungsbild gewährleisten soll. Zur Prüfung der Korrosionsbeständigkeit hat sich bei Schneidwaren aus MNS die Anwendung des Wechseltauchversuchs etabliert, dessen Ausweitung aufwendig und dessen Ergebnisse oftmals fragwürdig sind. In den letzten Jahren wurden daher neue elektrochemische Methoden entwickelt, um das Korrosionsverhalten von MNS objektiver zu bewerten. Diese neuen Untersuchungsmethoden ermöglichen eine genauere Erfassung der teilweise stark schwankenden Korrosionsbeständigkeit von MNS und bilden damit die Grundlage zur Aufklärung der Ursachen dieser Schwankungen. Im Rahmen des IGF-Vorhabens 16636 BG wurden dazu das elektrochemische Rauschen (ECR), das KorroPad und die elektrochemisch potentiodynamische Reaktivierung (EPR) eingesetzt, um die werkstoffseitigen Einflüsse der Mikrostruktur und den Einfluss der Oberflächenbearbeitung auf die Korrosionsbeständigkeit zu untersuchen. Es wurden dazu an drei weit verbreiteten MNS (1.4116, 1.4034 und 1.4021) je acht verschiedene Oberflächenzustände hergestellt und das Korrosionsverhalten untersucht. Um die dabei aufgetretenen Unterschiede im Lochkorrosionsverhalten zwischen den drei Werkstoffen zu erklären, wurde der EPR-Test eingesetzt, der lokale ChromVerarmung im Gefüge als werkstoffbedingte Ursache von Lochkorrosionsanfälligkeit nachweist. Mit der Kombination der Ergebnisse aus EPR, ECR und KorroPad war es möglich, die unterschiedliche Lochkorrosionsanfälligkeit direkt der unterschiedlich stark ausgeprägten Chromverarmung der drei MNS zuzuordnen. Der Einfluss der Chromverarmung auf die Lochkorrosionsanfälligkeit ist dabei deutlich größer als der Effekt der Oberflächenbearbeitung, der nur bei gering ausgeprägter Chromverarmung ersichtlich ist. Damit wurde gezeigt, dass nur bei Betrachtung aller Einflussgrößen sichere Aussagen zur Korrosionsbeständigkeit und zu den Ursachen der Lochkorrosionsanfälligkeit von MNS möglich sind.
In the last years, new approaches for the evaluation of the corrosion resistance of stainless steels were developed which allow short term corrosion testing with increased information content. This work analyses the extensive influence of heat treatment on microstructure and the resulting corrosion resistance of the martensitic stainless steels 1.4034 and 1.4021 with advanced methods. Different heat treatments at various austenitization temperatures up to 1100°C and the effect of different cooling rates were evaluated; the last has not yet been studied in literature at all. The resulting corrosion behaviour in relation to the different carbon content in the two used alloys and the applied heat treatment will be presented and discussed. The applied methods of investigation were conventional evaluation of the critical pitting corrosion potential (PP), modified electrochemical potentiodynamic reactivation (mEPR) and the "KorroPad" (KP) technique. The performance of modified EPR and its interpretation were optimized to provide additional information about the general passivation ability and the extent of chromium depletion as result of applied heat treatment. The aim using PP and KP was the correlation between the Parameters of the mEPR with the changes in the pitting corrosion resistance. Furthermore the results will demonstrate the functionality and usability of the short term corrosion test methods mEPR and KP in order to increase their acceptance within the scientific community. The results indicate a surprisingly large influence of both austenitization temperature and cooling rate on the corrosion resistance within all three used test methods, which can explain the different corrosion behaviour of martensitic stainless steels in earlier investigations.