In the literature, it has been shown that the naturally occurring trans-zearalenone (ZEN) is transformed by ultraviolet irradiation to cis-ZEN. However, the practical relevance of this transformation in animal feeding remains unclear. The aim of the present preliminary investigation was to examine the effect of UV-irradiation on the concentration of trans-ZEN in a natural feed matrix at different dry matter contents to simulate the dry and wet feeding techniques usually applied in pig feeding. Four variants, air dry or wet ZEN-contaminated ground maize either irradiated or not were tested and analysed with conventional HPLC-FLD for trans-ZEN changes, which were further examined for cis-ZEN formation by HPLC-MS/MS. In conclusion, it could be shown that, under the investigated wet feed conditions, naturally occurring trans-ZEN was partially converted by ultraviolet irradiation to its cis counterpart. In contrast, the cis/trans isomerization seemed not to be relevant in dry maize. The consequence of this finding for practical liquid feeding systems for pigs requires further investigation. Additionally, an improvement of the analytical method for cis-ZEN determination is needed.
The emphasis of the present work was to investigate the photochemical conversion of trans- to cis-zearalenone in edible oils under real-life conditions. For quantitation purposes a cis-zearalenone standard was synthesized and characterized for its identity and purity (≥95%) by 1H NMR, X-ray crystallography, HPLC fluorescence and mass spectrometric detection. In a sample survey of 12 edible oils (9 corn oils, 3 hempseed oils) from local supermarkets all corn oils contained trans-zearalenone (median 194 µg/kg), but no cis-zearalenone was detected. For alteration studies trans-zearalenone contaminated corn oils were exposed to sunlight over 4 and 30 weeks, revealing an obvious shift toward cis-zearalenone up to a cis/trans ratio of 9:1 by storage in colorless glass bottles. Irradiation experiments of trans-zearalenone in different organic solvents confirmed the preferred formation of cis-zearalenone possibly caused by entropic effects rather than by enthalpic entities as investigated by quantum chemical and classical force field simulations.
Pure U-[13C18]-labelled cis-zearalenone (cis-ZEA) has been prepared and characterised as internal standard (ISTD) for a reliable quantification of cis-ZEA in contaminated food and feed products. The cis-isomer of the naturally trans-configurated Fusarium mycotoxin zearalenone is often neglected. However, isomerisation easily occurs by exposure of ZEA to (UV-)light. Thus, the applicability of the new cis-ZEA ISTD was demonstrated in a long-term isomerisation study comparing naturally trans-ZEA-contaminated edible oil with spiked edible oil. To estimate the benefits of the newly prepared cis-ZEA ISTD, various approaches to quantify cis-ZEA by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) were compared. As a result, a significant bias was revealed if no appropriate cis-ZEA standards are used. Furthermore, the new ISTD was applied to the analysis of 15 edible oils by stable isotope dilution analysis in combination with HPLC-electrospray ionisation-MS/MS. One of the maize germ oils showed the presence of cis-ZEA above LOD (>0.3 µg/kg), whereas two out of 15 maize germ oils were found to be contaminated with trans-ZEA (range 17.0-31.0 µg/kg).
The title compound, also known as cis-zearalenone (cis-ZEN), C18H22O5, has already been reported elsewhere [Griffin et al. (1981). ACA Ser. 29, 35], but no atomic coordinates are publicly available. The molecule is of interest with respect to its toxicity. In the crystal, intramolecular O—H···O hydrogen bonds stabilize the molecular conformation, while intermolecular O—H···O hydrogen bonds link the molecules to form infinite chains along the [110] and [1¯10] directions. The absolute configuration has been assigned by reference to an unchanging chiral centre in the synthetic procedure.
Polycyclic aromatic hydrocarbons (PAHs) are a large group of priority organic pollutants, which contaminate environmental compartments, food, and consumer products as well. Due to their frequent occurrence associated with elevated Levels of PAHs, plastic and rubber parts of consumer products and toys are particular sources of exposure. Although European maximum levels exist for eight carcinogenic PAHs in consumer products and toys according to REACH Regulation (EC) No. 1907/2006, certified reference materials (CRM) are still not available. To overcome this lack, the first CRM for the determination of PAHs in rubber toys (BAM-B001) was developed according to the requirements of ISO Guide 35. The whole process of CRM development including preparation, homogeneity and stability studies, and value assignment is presented.
The assignment of the certified mass fractions was based upon in-house study at BAM using stable isotope Dilution analysis (SIDA) gas chromatography mass spectrometry (GC–MS). The obtained values were confirmed by the results of two interlaboratory comparison (ILC) studies with more than 50 expert laboratories from Germany and China. The mass fractions of 14 PAHs including all REACH and GS mark regulated compounds were certified ranging between 0.2 and 15.4 mg/
kg accompanied by expanded uncertainties (coverage factor k = 2). In addition, informative values were determined for 4 PAHs, mainly due to higher uncertainties and/or lack of ILC data for confirmation. BAM-B001 is intended for analytical quality control particularly based on the AfPS GS 2019:01 PAK method and contributes to improve the chemical safety of consumer products including toys.
Three chromatographic procedures were investigated regarding their potential for the quantification of aniline and 19 of its methylated and chlorinated derivatives in groundwater. These methods were based on liquid-liquid-extraction in combination with gas chromatography and single quadrupole mass spectrometry (GC/MS) according to German standard DIN 38407-16:1999 and its extension using tandem mass spectrometry (GC/MS-MS), both following liquid-liquid extraction, and as third alternative the direct injection of the water sample into a liquid chromatograph coupled to tandem mass spectrometry (LC/MS-MS). Results were compared using fortified water and real-world contaminated groundwater used in an interlaboratory comparison. It could be shown that GC/MS and GC/MS-MS yielded results deviating less than 10% from each other while all three procedure displayed quantification results deviating less than 15% from the intercomparison reference values in case of each analyte in the concentration range between 1 and 45 µg L-1. Though GC/MS-MS displays a ten-fold higher sensitivity than single quadrupole GC/MS, the precision of both methods in the concentration range was similar. LC/MS-MS has the advantage of no further sample preparation due to the direct injection and leads for methylanilines and meta-, para- substituted chloroanilines to results sufficiently equivalent to the standardised GC/MS method. However, LC/MS-MS is not suitable for ortho-chloroaniline derivates due to significantly lower ion yields than meta- and para-substituted chloroanilines.
Zearalenone (ZEN), an estrogenic mycotoxin produced by several species of Fusarium fungi, is a common contaminant of cereal-based food worldwide. Due to frequent occurrences associated with high levels of ZEN, maize oil is a particular source of exposure. Although a European maximumlevel for ZEN in maize oil exists according to Commission Regulation (EC) No. 1126/2007 along with a newly developed international standard method for analysis, certified reference materials (CRM) are still not available. To overcome this lack, the first CRM for the determination of ZEN in contaminated maize germ oil (ERM®-BC715) was developed in the frame of a European Reference Materials (ERM®) project according to the requirements of ISO Guide 35. The whole process of CRM development including preparation, homogeneity and stability studies, and value assignment is presented. The assignment of the certified mass fraction was based upon an in-house study using high-performance liquid chromatography isotope dilution tandem mass spectrometry. Simultaneously, to support the in-house certification study, an interlaboratory comparison study was conducted with 13 expert laboratories using different analytical methods. The certified mass fraction and expanded uncertainty (k=2) of ERM®-BC715 (362± 22) μg kg−1 ZEN are traceable to the SI. This reference material is intended for analytical quality control and contributes to the improvement of consumer protection and food safety.
The CCQM-K148.a comparison was coordinated by the BIPM on behalf of the CCQM Organic Analysis Working Group for NMIs and DIs which provide measurement services in organic analysis under the CIPM MRA. It was undertaken as a "Track A" comparison within the OAWG strategic plan. CCQM-K148.a demonstrates capabilities for assigning the mass fraction content of a solid organic compound having moderate molecular complexity, where the compound has a molar mass in the range (75 - 500) g/mol and is non-polar (pKow < −2), when present as the primary organic component in a neat organic solid and where the mass fraction content of the primary component in the material is in excess of 950 mg/g.
Participants were required to report the mass fraction of Bisphenol A present in one supplied unit of the comparison material. Participants using a mass balance method for the assignment were also required to report their assignments of the impurity components present in the material. Methods used by the seventeen participating NMIs or DIs were predominantly based on either stand-alone mass balance (summation of impurities) or qNMR approaches, or the combination of data obtained using both methods. The results obtained using thermal methods based on freezing-point depression methods were also reported by a limited number of participants. There was excellent agreement between assignments obtained using all three approaches to assign the BPA content.
The assignment of the values for the mass fraction content of BPA consistent with the KCRV was achieved by most of the comparison participants with an associated relative standard uncertainty in the assigned value in the range (0.1 - 0.5)%.
Rapid, cost-efficient, and eco-friendly methods are desired today for routine analysis of the Fusarium mycotoxin zearalenone (ZEN) in edible vegetable oils. Liquid chromatography with fluorescence detection (HPLC-FLD) is commonly used to reliably control the specified ZEN maximum levels, which requires efficient sample clean-up to avoid matrix interferences. Therefore, a highly selective extraction and clean-up method based on reversible covalent hydrazine chemistry (RCHC) using hydrazine-functionalized silica was developed. This efficient solid-phase extraction (SPE) involves reversible hydrazone formation of ZEN with the hydrazine moiety covalently bound to a solid phase. Optimal conditions were achieved with 1 mL SPE cartridges filled with 400 mg of hydrazine-functionalized silica. The developed RCHC-SPE method was validated in an interlaboratory comparison study (ILC) with twelve participants analyzing six edible vegetable oils with a focus on maize oils. The derived method parameters (ZEN recovery 83%, repeatability 7.0%, and reproducibility 18%) meet the performance criteria of Commission Regulation (EC) No 401/2006. The developed RCHC-SPE-based HPLC-FLD method allows the reliable quantification of ZEN in the range of 47–494 μg/kg for different types of edible vegetable oils, also for matrix-reach native oils. Due to the high efficiency, the significantly reduced matrix load helps to extend the lifetime of analytical equipment. Furthermore, the re-useability of the RCHC-SPE cartridges contributes to an eco-friendly approach and reduced analysis costs. To our knowledge, this is the first report on ZEN quantification in edible vegetable oils based on manual RCHC-SPE cartridges. Due to its high performance, the developed RCHC-SPE method is a promising alternative to the current European standard method EN 16924:2017 (HPLC-FLD part).
Data file (RData) containing measurement data recorded during the production process of the Certified Reference Material BAM-A001 containing Polycyclic Aromatic Hydrocarbons (PAH) in olive oil. The data can be most conveniently openend using the Shiny-App eCerto which is accessible at https://www.bam.de/eCerto.