Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (46)
- Vortrag (5)
- Beitrag zu einem Tagungsband (4)
- Posterpräsentation (3)
Schlagworte
- Mass spectrometry (10)
- Acoustic levitation (5)
- Ambient mass spectrometry (5)
- High repetition rate (5)
- Laser (5)
- Ion mobility spectrometry (4)
- Laser-induced breakdown spectroscopy (4)
- Laser-induced plasma (4)
- Mass Spectrometry (4)
- Plasma (4)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (24)
- 1.3 Instrumentelle Analytik (19)
- P Präsident (10)
- 1.9 Chemische und optische Sensorik (9)
- PST Präsidiale Stabsstelle (8)
- 6 Materialchemie (6)
- 6.3 Strukturanalytik (6)
- P.0 Präsident und andere (4)
- 1.1 Anorganische Spurenanalytik (3)
- 1.5 Proteinanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- S Qualitätsinfrastruktur (2)
- S.1 Qualität im Prüfwesen (2)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 7 Bauwerkssicherheit (1)
- 7.7 Modellierung und Simulation (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.0 Abteilungsleitung und andere (1)
- VP Vizepräsident (1)
- VP.1 eScience (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (5)
High repetition rate laser-induced breakdown spectroscopy using acousto-optically gated detection
(2014)
This contribution introduces a new type of setup for fast sample analysis using laser-induced breakdown spectroscopy (LIBS). The novel design combines a high repetition rate laser (up to 50 kHz) as excitation source and an acousto-optical modulator (AOM) as a fast switch for temporally gating the detection of the emitted light. The plasma radiation is led through the active medium of the AOM where it is diffracted on the transient ultrasonic Bragg grid. The diffracted radiation is detected by a compact Czerny-Turner spectrometer equipped with a CCD line detector. Utilizing the new combination of high repetition rate lasers and AOM gated detection, rapid measurements with total integration times of only 10 ms resulted in a limit of detection (LOD) of 0.13 wt.% for magnesium in aluminum alloys. This short integration time corresponds to 100 analyses/s. Temporal gating of LIP radiation results in improved LODs and consecutively higher sensitivity of the LIBS setup. Therefore, an AOM could be beneficially utilized to temporally detect plasmas induced by high repetition rate lasers. The AOM in combination with miniaturized Czerny-Turner spectrometers equipped with CCD line detectors and small footprint diode pumped solid state lasers results in temporally gateable compact LIBS setups.
This paper presents a numerical and an experimental procedure to obtain the pressure field in single-axis acoustic levitators. Numerically, the pressure field is determined by a matrix method based on the Rayleigh integral that take into account the multiple wave reflections that occur between the transducer and the reflector. The numerical pressure field is compared with the acoustic pressure measured by an earplug microphone, that is connected to a hollow needle. The tip of the needle is moved by a µm translation stage through the field and the signal is recorded using a lock-in amplifier locked to the levitator frequency. The pressure field obtained numerically show good agreement with that obtained experimentally.
In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis.
The novel combination of infrared matrix-assisted laser dispersion and inization (IR-MALDI) with ion mobility (IM) spectrometry makes it possible to investigate biomolecules in their natural environment, liquid water. As an alternative to an ESI source, the IR-MALDI source was implemented in an in-house-developed ion mobility (IM) spectrometer. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse (λ = 2.94 μm, 6 ns pulse width), which disperses the liquid as nano- and micro-droplets. The prerequisites for the application of IR-MALDI-IM spectrometry as an analytical method are narrow analyte ion signal peaks for a high spectrometer resolution. This can only be achieved by improving the desolvation of ions. One way to full desolvation is to give
the cluster ions sufficient time to desolvate. Two methods for achieving this are studied: the implementation of an additional drift tube, as in ESI-IM-spectrometry, and the delayed extraction of the ions. As a result of this optimization procedure, limits of detection between 5 nM and 2.5 μMas well as linear dynamic ranges of 2–3 orders of magnitude were obtained for a number of substances. The ability of this method to analyze simple mixtures is illustrated by the separation of two different surfactant mixtures.
Infraredmatrix-assisted laser dispersion and ionization(IR-MALDI) in combination with on mobility (IM) spectrometry enables the direct Analysis of biomolecules in aqueous solution. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the Absorption of an IR laser pulse, which disperses the liquid as vapor, nano- and micro-droplets. The ionization process is characterized initially by a broad spatial distribution of the ions, which is a result of complex fluid dynamics and desolvation kinetics. These processes have a profound effect on the shape and width of the peaks in the IM spectra. In this work, the Transport of ions by the phase explosion-induced shockwave could be studied independently from the transport by the electric field. The shockwave-induced mean velocities of the ions at different time scales were determined through IM spectrometry and shadowgraphy. The results show a deceleration of the Ions from 118m∙s−1 at a distance of 400 μm from the liquid surface to 7.1 m∙s−1 at a distance of 10 mm, which is caused by a pileup effect. Furthermore, the desolvation kinetics were investigated
and a first-order desolvation constant of 325 ± 50 s−1
was obtained. In the second part, the IR-MALDI-IM
spectrometer is used as an HPLC detector for the twodimensional separation of a pesticide mixture.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual cam-paigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The re-sulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via compara-bly straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algo-rithm to interpret the ob-tained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s.
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of 1H spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibrationfree approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h-1 at 25 °C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance.
Currently, research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques.
Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16-inch polymer tubing working as a flow cell. Single scan 1H NMR spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments.
Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
A wide range of aspects concerning microscope slides, their preparation, long-time storage, curatorial measures in collections, deterioration, restoration, and study is summarized based on our own data and by analyzing more than 600 references from the 19th century until 2016, 15 patents, and about 100 Materials Safety Data Sheets. Information from systematic zoology, conservation sciences, chemistry, forensic sciences, pathology, paleopathology, applied sciences like food industry, and most recent advances in digital imaging are put together in order to obtain a better understanding of which and possibly why mounting media and coverslip seals deteriorate, how slides can be salvaged, which studies may be necessary to identify a range of ideal mounting media, and how microscope studies can benefit from improvements in developmental biology and related fields. We also elaborate on confusing usage of concepts like that of maceration and of clearing.
The chemical ingredients of a range of mounting media and coverslip seals are identified as much as possible from published data, but this information suffers in so far as the composition of a medium is often proprietary of the manufacturer and may vary over time. Advantages, disadvantages, and signs of deterioration are documented extensively for these media both from references and from our own observations. It turns out that many media degrade within a few years, or decades at the latest, except Canada balsam with a documented life-time of 150 years, Euparal with a documented life-time of 50 years, and glycerol-paraffin mounts sealed with Glyceel, which represents almost the only non-deteriorating and easily reversible mount. Deterioration reveals itself as a yellowing in natural resins and as cracking, crystallization, shrinkage on drying or possibly on loss of a plasticizer, detachment of the coverslip, segregation of the ingredients in synthetic polymers, as well as continued maceration of a specimen to a degree that the specimen virtually disappears. Confusingly, decay does not always appear equally within a collection of slides mounted at the same time in the same medium. The reasons for the deteriorative processes have been discussed but are controversial especially for gum-chloral media. Comparing data from conservation sciences, chemical handbooks, and documented ingredients, we discuss here how far chemical and physical deterioration probably are inherent to many media and are caused by the chemical and physical properties of their components and by chemicals dragged along from previous preparation steps like fixation, chemical maceration, and physical clearing. Some recipes even contain a macerating agent, which proceeds with its destructive work. We provide permeability data for oxygen and water vapor of several polymers contained in mounting media and coverslip seals. Calculation of the penetration rate of moisture in one example reveals that water molecules reach a specimen within a few days up to about a month; this lays to rest extensive discussions about the permanent protection of a mounted specimen by a mounting medium and a coverslip seal.
Based on the ever growing evidence of the unsuitable composition and application of many, and possibly almost all, mounting media, we strongly encourage changing the perspective on microscope slides from immediate usability and convenience of preparation towards durability and reversibility, concepts taken from conservation sciences. Such a change has already been suggested by Upton (1993) more than 20 years ago for gum-chloral media, but these media are still encouraged nowadays by scientists. Without a new perspective, taxonomic biology will certainly lose a large amount of its specimen basis for its research within the next few decades. Modern non-invasive techniques like Raman spectroscopy may help to identify mounting media and coverslip seals on a given slide as well as to understand ageing of the media. An outlook is given on potential future studies.
In order to improve the situation of existing collections of microscope slides, we transfer concepts as per the Smithsonian Collections Standards and Profiling System, developed for insect collections more than 25 years ago, to collections of slides. We describe historical and current properties and usage of glass slides, coverslips, labels, and adhesives under conservational aspects. In addition, we summarize and argue from published and our own experimental information about restorative procedures, including re-hydration of dried-up specimens previously mounted in a fluid medium. Alternatives to microscope slides are considered. We also extract practical suggestions from the literature concerning microscope equipment, cleaning of optical surfaces, health risks of immersion oil, and recent improvements of temporary observation media especially in connection with new developments in digital software.
A novel ionization scheme for ambient mass spectrometry is presented and discussed. Desorption and ionization are achieved by a quasi-continuous laser induced plasma (LIP) ignited in front of the atmospheric pressure interface of a time-of-flight mass spectrometer. This setup comprises the advantages of i) an ambient probe, ii) electro neutrality, iii) low power consumption, iv) a sufficient duty cycle, v) a ubiquitous plasma medium (air) and vi) high sensitivity caused by the high electron number densities.
The plasma properties and operating conditions are investigated to understand the processes that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry investigations. The observed MS signal (including reagent-ion signal, as well as analyte spectra) closely resembles the ionization behavior of other electrically-driven plasma-based ionization sources, such as DBD, LTP or DART. Conversely that means that although LIPs are commonly known to have temperatures way above 10.000 K and thus efficiently atomize and ionize molecules, MS spectra were obtained that showed the formation of intact molecular ions.
For an insight into the LIP properties the optical emission of the LIP is examined and exhibits a pronounced degree of dissociation into atomic and ionic species, which reflects the higher temperature and electron density inside a LIP. Accordingly, rather elemental (ICP-type) than molecular spectra should be expected. However due to the absence of such ions, we conclude that the analyte does not enter the hot center of the plasma itself. Moreover, the initial, highly-excited plasma species react cascade-like to lower energetic species via reactive collision with the surrounding atmosphere, which can then subsequently ionize molecules of interest. The concept potentially involves charge transfer, proton transfer, electron impact and photoionization.
These assumptions are confirmed via the shadowgraphs of the expanding shockwave around the LIP. An effective spatial separation between the two regions is maintained by concentrically expanding pressure waves resulting in a strongly unidirectional diffusion. Additionally, the strictly outbound matter transport suggests a rarefaction inside the plasma region for each plasma event.