Purity statements of high purity materials serving as primary standards by GDMS.
Primary standards are materials known for their total purity and therefore appropriate to realise the link with the International System of Units (SI). The realisation and dissemination of primary standards is of fundamental importance for comparability of measurement results through traceability in all fields of chemical analysis.
To serve as a primary standard for element determination the total purity of a high purity material needs to be measured. In order to achieve a sufficiently small uncertainty (i.e. < 0.01%) this involves determining all possible impurity contributions and to subtract their sum from the ideal purity of 100%.
GD-MS has the potential to reduce the effort for purity determination, as a fast sensitive multi-element analysis without extensive sample preparation. Similar to other solid sampling techniques, glow discharge
requires calibration link the measured signal and the content of the impurities in the matrix.
The use of the concept Relative Sensitivity Factors (RSFs) provides good approximations especially for high purity materials. However, it only works with a wide uncertainty of the results.
The preparation of synthetic pressed powder samples by different modifications of liquid and powder doping used for the determination of both metallic and none-metallic impurities are described. Efficient determination of metallic impurities by GD-MS via differential and absolute measurements with a significantly reduced target uncertainty of 20 % for absolute measurements using liquid doped pressed powder calibration could be achieved. The determination of impurities has been evaluated by independent analytical methods such as HR-ICP-MS, ETAAS; CGHE and combustion analysis
In supplementary work to the one published earlier, experiments with SF6, NF3, CF4 and H2 as new modifier gases for the matrix studied were performed. Our investigations were continued to improve the described analytical method and to achieve additional insights into the mechanism of analyte release. Our new survey is split in two parts. At first fluorinating modifiers were used to investigate the behaviour of a variety of trace elements (Ag, Al, As, Au, Bi, Cd, Co, Cr, Fe, Mg, Mn, Ni, P, Pb, Sb, Se, Si, Sn, Te, Ti, Zn and Zr). Most of them (exceptions Au, Se, and Te) could be effectively released from the copper matrix by thermo-halogenation reactions and by partial sub-sample evaporation. Using SF6 and NF3 as modifier gases, low limits of quantification (LOQs) were achieved for the 19 well released trace elements (typical ≤0.1 mg kg-1). Most elements (exceptions Ag, Mg, and Ni) could be calibrated by using aqueous calibration solutions without any sample pretreatment. For the trace determination of Se, Te, and Au, a further analytical method of ETV-ICP OES is described in the second part based on thermo-hydrogenation reactions by using a hydrogen/argon mixture as a modifier gas. The determination of Se and Te with very high analytical performance (LOQ < 0.1 mg kg-1) can either be carried out in a second analytical step succeeding the halogenation procedure, or the sub-sample is directly treated with H2 without previous halogenation procedure whereby the sub-sample can either be partially or totally evaporated. In this case some other analytes (Ag, Au, As, Bi, Cd, Fe, Mg, Ni, Pb, Sb, Sn, and Zn) can additionally be quantified simultaneously with Se and Te.