Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (18)
- Beitrag zu einem Tagungsband (18)
- Vortrag (14)
- Posterpräsentation (8)
- Forschungsbericht (2)
- Buchkapitel (1)
- Dissertation (1)
Sprache
- Englisch (40)
- Deutsch (21)
- Mehrsprachig (1)
Schlagworte
- VOC (15)
- Emission test chamber (11)
- Radon exhalation (6)
- Volatile organic compounds (6)
- Indoor air quality (5)
- Thermal desorption (5)
- CO2 assisted impregnation (4)
- Gas chromatography (4)
- Indoor air (4)
- Reference material (4)
- Building material (3)
- Building materials (3)
- Emission reference material (3)
- FEM model (3)
- Radon (3)
- Radon measurement (3)
- VVOC (3)
- Air sampling (2)
- Baumaterialien (2)
- Emission studies (2)
- Emission testing (2)
- Emissions testing (2)
- Gas mixing device (2)
- Healthy homes and buildings (2)
- ISO 16000-6 (2)
- Low emissions (2)
- Lüftung (2)
- Materialemission (2)
- Micro-chamber (2)
- Natural ventilation (2)
- Product safety (2)
- Reference materials (2)
- Schadstoffemission (2)
- Sources/emissions (2)
- VOC-Emission (2)
- Volatile organic compound (2)
- Adsorptive wall material (1)
- Air analysis (1)
- Air cleaning (1)
- Air-tight building envelope (1)
- Airtight building (1)
- Baustoffe (1)
- Bio-based insulation (1)
- Blauer Engel (1)
- Calibration transfer (1)
- Capsules (1)
- Certification/labelling (1)
- Chamber test (1)
- Chamber-test (1)
- Climate control through building elements (1)
- Climate responsive materials (1)
- Construction material (1)
- Construction materials (1)
- Construction product (1)
- Construction products (1)
- Dynamic calibration gas mixtures (1)
- Dynamic gas generation (1)
- Earthen building materials (1)
- Emission (1)
- Emission aus Materialien (1)
- Emission from materials (1)
- Emission of pollutants from building materials (1)
- Emission reference materials (1)
- Emissions-Referenzmaterial (1)
- Emissions-Referenzmaterialien (1)
- Emissionsarme Materialien (1)
- Emissionsprüfkammer (1)
- Emitting reference material (1)
- Evaporation (1)
- Feuchtesorption (1)
- Formaldehyde (1)
- Gas atmosphere (1)
- Gas mixing system (1)
- Hygroscopic earth and wooden materials (1)
- Hygroscopic earthen and wooden building materials (1)
- Hygroscopic earthen and wooden materials (1)
- Hygroskopische Lehm- und Holzbaustoffe (1)
- IEQ (1)
- Indoor Air: Adsorbent performance (1)
- Innenraumlufthygiene (1)
- Inter-lab comparison (1)
- Inter-laboratory study (1)
- Interlaboratory comparison (1)
- Kalibrierung (1)
- LCC (1)
- Laboratory studies (1)
- Low VOC concentrations (1)
- Low gas concentrations (1)
- Low-tech approach (1)
- Luftdichte Gebäudehülle (1)
- Material and construction (1)
- Material emissions (1)
- Materialadsorption (1)
- Materialemissionen (1)
- Materials emissions test (1)
- Materials emissions testing (1)
- Measurement method (1)
- Measurements (1)
- Natural materials (1)
- Naturbaustoffe (1)
- Natürliche Baumaterialien (1)
- Natürliche Belüftung (1)
- Odour (1)
- Perceived intensity (1)
- Poficiency test (1)
- Polymer (1)
- Polymer material (1)
- Polymeric material (1)
- Proficiency Test (1)
- Proficiency testing (1)
- Prüfgasgenerierung (1)
- Prüfmethode (1)
- Prüfverfahren (1)
- Quality assurance (1)
- Quality assurance/quality control (1)
- Quality control (1)
- Qualitätssicherung (1)
- Radon monitors (1)
- Real room radon concentrations (1)
- Recovery rate (1)
- Ringversuche (1)
- Risk assessment (1)
- Robustness validation (1)
- Round robin test (1)
- Rround robin test (1)
- SVOC (1)
- Schadstoffadsorption (1)
- Schadstoffemission von Baustoffen (1)
- Schadstoffsorption (1)
- Selective quantification (1)
- Semivolatile organic compounds (1)
- Solvents (1)
- Sorption flux (1)
- Sorptive construction materials (1)
- Standardisation (1)
- Test gas generation (1)
- Test procedure (1)
- VOC emission (1)
- VOC emission test chamber (1)
- VOC gas mixtures (1)
- VOC-Gasgenische (1)
- VOC-emission (1)
- Wasserdampfsorption (1)
- natural ventilation (1)
Organisationseinheit der BAM
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (14)
Die größten Ressourcenverbraucher unserer Zeit sind die Gebäude oder Behausungen des Menschen sowohl in der Phase der Errichtung als auch im Betrieb. Der Gebäudesektor und damit auch die Architektur verbrauchen in Deutschland ca. 50 % der fossilen Energieressourcen und verursachen ca. 60 % des gesamten Müllaufkommens mit dem zugehörigen Bedarf an Ressourcen in der Errichtung. Öl, Stahl und Beton haben uns Glauben gemacht die natürlichen Begebenheiten bei der Gestaltung von Gebäuden wenig beachten zu müssen. Immer neue Techniken zum Betrieb und zur Klimatisierung von Gebäuden waren die Zukunft. Der Klimawandel und die Ressourcenknappheit sind Aufforderungen zur Veränderung. Das Voranschreiten der Reform des Bauwesens hat somit zentrale Bedeutung zur Erreichung der Nachhaltigkeitsziele und um unsere Gesellschaft zukunftsfähig zu machen. Klimaangepasste Architekturkonzepte und die Verwendung von klimaaktiven Naturbaustoffen werden einen wesentlichen Beitrag zum Ressourcenschutz erbringen.
Multi residential buildings, developed as highly energy-efficient and airtight are nowadays often fitted with mechanical Ventilation Systems as a way to overcome shortcomings and even defects tinked to indoor climate. The presented study investigates the potential of low-emitting. natural building materials with hygroscopic properties to contribute to a healthy and comfortable indoor environment, while reducing the need for mechanical Ventilation.
A selection of natural building materials suitable for application as internal partition walls has been investigated with regards to their water vapour adsorption capacity.
Special emphasis was placed on the investigation of modified earth plasters as well as wood-based materials, used as wall lining to provide increased adsorption capacities.
In addition, tests on materials emissions (formaldehyde, VOCs, SVOCs and radon) as well as adsorption tests of airborne pollutants have been conducted in specially-designed fest chambers. All tests were performed at either the material or the component tevel.
Overall results to date suggest that natural materials contribute to an improved indoor environment quality through an increased moisture-buffering capacity, low emissions and the potential to adsorb airborne pollutants, therefore reducing the need for mechanical Ventilation.
The inhalation of radon (222Rn) decay products is the leading cause of lung cancer apart from tobacco smoking. Besides the permeation of radon from the subsoil through the basement as main source of radon in indoor air, also building materials have to be taken into consideration, especially at low air change rates in buildings. The Construction Products Regulation (EC, 2010) gives essential requirements for construction works regarding the release of dangerous substances such as toxic gases and radiation to which radon can be assigned. The recently adopted Basic Safety Standards Directive (EC, 2013), which has to be ratified by each European member state in between the next three years sets reference levels for indoor radon concentrations for the first time. In research project financed by the German Ministry for the Environment, Nature Conservation, Building and Nuclear Safety a practical, reliable and easily applicable test procedure for the determination of radon exhalation from building materials – based on ISO 16000-9 (ISO, 2006) and CEN/TS 16516 (CEN, 2013) – should be developed. In contrast to the static test procedure published by Richter et al. (2013), dynamically operated test chambers shall be foregrounded. First results of this study are presented, focused on the reliable measurement of radon background concentration and the selection of suitable radon test devices, representing the basic elements of the subsequent work.
Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany.
Development of a multi-VOC reference material for quality assurance in materials emission testing
(2015)
Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandatory. Currently, there is a lack of such materials because most building products show a broad variation of emissions even within one batch. A previous study indicates lacquers, mixed with volatile organic pollutants, as reproducible emission source for a wide range of substances. In the present study, the curing of the lacquer-VOC mixture inside micro-chambers was optimised. Therefore, the humidity and the chamber flow were varied. Typical indoor air pollutants with a wide range of volatilities, for example, styrene, n-hexadecane, dimethyl and dibutyl phthalate were selected. It turned out that, under optimised curing parameters inside the micro-chamber, their emission can be reproduced with variations of less than 10 %. With this, a next important step towards a reference material for emission testing was achieved.
Volatile organic compounds (VOCs) found indoors have the potential to affect human health. Typical sources include building materials, furnishings, cleaning agents, etc. To address this risk, chemical emission testing is used to assess the potential of different materials to pollute indoor air. One objective of the European Joint Research Project 'MACPoll' (Metrology for Chemical Pollutants in Air) aims at developing and testing a reference material for the quality control of the emission testing procedure. Furthermore, it would enable comparison of measurement results between test laboratories. The heterogeneity of the majority of materials makes it difficult to find a suitable reference sample.
In the present study, styrene, 2-ethyl-1-hexanol, N-methyl-α-pyrrolidone, lindane, n-hexadecane, 1,2-dimethyl- and 1,2-di-n-butyl-phthalate were added to 12 commercially available lacquers (6 alkyd and 6 acrylic polymer based lacquers) serving as carrier substrate. After homogenization, the mixtures were loaded into a Markes Micro-Chamber/Thermal Extractor (µ-CTE) for curing and investigation of the emission behavior for each compound. For almost all of the investigated chemicals, the preferred glossy acrylic lacquer showed emissions that were reproducible with a variation of less than 20% RSD. Such lacquer systems have therefore been shown to be good candidates for use as reference materials in inter-laboratory studies.