Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (18)
- Beitrag zu einem Tagungsband (18)
- Vortrag (14)
- Posterpräsentation (8)
- Forschungsbericht (2)
- Buchkapitel (1)
- Dissertation (1)
Sprache
- Englisch (40)
- Deutsch (21)
- Mehrsprachig (1)
Schlagworte
- VOC (15)
- Emission test chamber (11)
- Radon exhalation (6)
- Volatile organic compounds (6)
- Indoor air quality (5)
- Thermal desorption (5)
- CO2 assisted impregnation (4)
- Gas chromatography (4)
- Indoor air (4)
- Reference material (4)
Organisationseinheit der BAM
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (14)
In dieser Arbeit wird die Entwicklung sowie Validierung eines Verfahrens zur Erzeugung langzeitstabiler VOC-Gasgemische im Konzentrationsbereich zwischen wenigen μg/m³ und einigen 100 μg/m³ beschrieben. Das Prinzip basiert auf der Verdampfung von Reinsubstanzen, die separat in Fläschchen aus Edelstahl gefüllt sind und in ihnen temperiert werden. Je nach Dampfdruck der eingefüllten Verbindungen tritt mehr oder weniger Substanz aus der Flüssig- in die Gasphase über. Ein in die Flaschen eingeleitetes Trägergas nimmt Substanzgas aus dem Gasraum auf und transportiert es in eine Gasmischkammer, in der alle Substanzdämpfe vereinigt werden. Der Trägergasstrom ist dabei so klein, dass er das Quasigleichgewicht in den Fläschchen nur wenig stört und wegen des schnellen Stoffübergangs als gesättigt angenommen werden kann. Durch die Kombination von Verdampfungstemperatur, Träger- und Verdünnungsgasflüssen ist die Einstellung eines beliebigen Konzentrationsniveaus des Gasgemischs möglich. Mit dem entwickelten Aufbau war es möglich, ein Gasgemisch aus insgesamt 25 Komponenten zu generieren. Dabei konnte für 16 der Komponenten eine stabile und reproduzierbare Gaskonzentration nachgewiesen werden. Bei den übrigen waren teilweise starke Schwankungen über den Versuchszeitraum zu beobachten. Das konnte auf konstruktionsseitige Undichtigkeiten an den Fläschchen bzw. im Leitungssystem zurückgeführt werden, die schließlich nicht komplett beseitigt werden konnten. Ein Senkeneffekt in der Anlage kann ausgeschlossen werden, und die chemische Stabilität der eingefüllten Substanzen konnte – mit Ausnahme einiger Aldehyde – nachgewiesen werden. Das Verfahren wurde erfolgreich für die Generierung von Gasstandards für einen Ringversuch eingesetzt. Ferner fand es Anwendung in einem Materialtest, bei dem die sorbierenden Eigenschaften eines Bauprodukts unterschiedlicher Zusammensetzung gegenüber den Gaskomponenten untersucht wurden. Damit konnte die Praxistauglichkeit gezeigt werden.
The development of a gas mixing system (GMS) that enables dynamic and retraceable production of stable long-term VOC gas mixtures within the ppb range is discussed. In this system pure liquid substances are kept separately at a constant temperature, evaporated according to their vapour pressure and removed by a small inert gas flow. A modular set-up allows flexible handling. All vapours generated are finally united in a mixing chamber. Any concentration level of the gas mixture can be produced by a suitable combination of evaporation temperature, carrier and dilution gas flows. Test results from continuous operation over six weeks are presented. The equipment was tested on seven volatile organic compounds (VOC) of different vapour pressure ranges. It was possible to establish stable operation for the equipment during the entire period and reproducible gas concentrations which were traceable to the mass as an SI unit, thus the system is suitable for long-term tests.---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Im Beitrag wird die Entwicklung eines Gasmischsystems (GMS) beschrieben, das die dynamische und rückführbare Generierung von langzeitstabilen VOC-Gasgemischen im ppb-Bereich erlaubt. Dabei werden Reinsubstanzen separat temperiert, ihrem Dampfdruck entsprechend verdampft und durch einen kleinen Inertgasstrom abgeführt. In einer Mischkammer werden sie schließlich zusammengeführt. Durch die Kombination von Verdampfungstemperatur, Träger- und Verdünnungsgasflüssen ist die Einstellung eines beliebigen Konzentrationsniveaus des Gasgemischs möglich. Aus einem Dauerbetrieb von sechs Wochen werden Untersuchungsergebnisse gezeigt. Dabei wurde die Apparatur mit insgesamt sieben flüchtigen organischen Verbindungen (VOC) unterschiedlicher Dampfdruckbereiche betrieben. Die Anlage lief über den gesamten Zeitraum stabil und lieferte reproduzierbare und auf die Masse als SI-Einheit rückführbare Gaskonzentrationen. Somit ist das Verfahren für Langzeitanwendungen geeignet.
Entwicklung einer praxisnahen Prüfmethode zur Bestimmung der Radon-Exhalation aus Bauprodukten
(2012)
Determination of radon exhalation rates from construction materials using VOC emission test chambers
(2013)
Determination of radon exhalation from construction materials using VOC emission test chambers
(2013)
The inhalation of 222Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials – two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick – generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing.
The ISO 16000-6 standard gives directions to adapt the analysis of volatile organic compounds (VOCs) in indoor and test chamber air to very volatile organic compounds (VVOCs). The same techniques with sorbent-based active sampling, thermal desorption and gas chromatography coupled with mass spectrometry (TD-GC/MS) should be used. However, VVOCs require gaseous standards, an adapted GC column and a reliable sampling adsorbent. This work presents experimental results to tackle those three experimental gaps. A stable standard gas mixture containing 47 VVOCs, 13 VOCs and an internal standard was successfully generated. It was employed to study the suitability of seven types of chromatography columns. The use of PLOT (Porous Layer Open Tubular) columns such as PoraBOND Q is well suitable for VVOC analysis. The recoveries of the 60 analytes on a total of 16 adsorbents and their combinations were determined: A combination of the graphitized carbon black Carbograph 5TD 40/60 and the carbon molecular sieve CarbosieveTM SII showed great recoveries for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. A dry purge of the multi-sorbent in the sampling direction led to a complete water removal and promising recoveries of the analytes.
Earth, timber, fibre boards and insulation materials based on wooden and other natural fibres offer a variety of properties beneficial for eco innovative constructions that are able to improve the energy and resource efficiency of buildings.
Due to their porosity, natural building materials are vapour active and are able to buffer moisture. In combination with highly insulated and airtight but vapour permeable building envelopes, modern earth-timber constructions provide stable indoor humidity levels and can therefore be naturally ventilated while achieving highest energy efficiency standards. Experimental evidence suggests that monitored pilot buildings in Berlin do show healthy indoor air humidity levels (around 50%) in wintertime, while mechanically ventilated buildings demonstrate significantly lower values (around 25%), which have to be considered as uncomfortable and unhealthy.
The application of building materials being poor in chemical emissions, particularly volatile organic compounds (VOC) and radon, improves the indoor air quality further, so that intermittent ventilation twice a day will be sufficient to provide healthy indoor air quality. The air quality in critical rooms (e.g. small bedrooms), demonstrating a smaller air volume, should be monitored if appropriate ratios of room size to occupancy level cannot be realised.
Through night time ventilation in summer, vapour active earth-timber constructions provide evaporative cooling (humidity adsorption at night time and desorption during the day). As a result, indoor temperatures of earth-timber buildings range around 8 °C below the outside temperature peak, when an appropriate glazing ratio is reflected. The EU funded research project H-house is investigating various construction materials regarding water vapour adsorption as well as emission and absorption of harmful substances. Based on this investigation new wall constructions are designed to provide a healthier indoor environment.
Volatile organic compounds (VOCs) found indoors have the potential to affect human health. Typical sources include building materials, furnishings, cleaning agents, etc. To address this risk, chemical emission testing is used to assess the potential of different materials to pollute indoor air. One objective of the European Joint Research Project 'MACPoll' (Metrology for Chemical Pollutants in Air) aims at developing and testing a reference material for the quality control of the emission testing procedure. Furthermore, it would enable comparison of measurement results between test laboratories. The heterogeneity of the majority of materials makes it difficult to find a suitable reference sample.
In the present study, styrene, 2-ethyl-1-hexanol, N-methyl-α-pyrrolidone, lindane, n-hexadecane, 1,2-dimethyl- and 1,2-di-n-butyl-phthalate were added to 12 commercially available lacquers (6 alkyd and 6 acrylic polymer based lacquers) serving as carrier substrate. After homogenization, the mixtures were loaded into a Markes Micro-Chamber/Thermal Extractor (µ-CTE) for curing and investigation of the emission behavior for each compound. For almost all of the investigated chemicals, the preferred glossy acrylic lacquer showed emissions that were reproducible with a variation of less than 20% RSD. Such lacquer systems have therefore been shown to be good candidates for use as reference materials in inter-laboratory studies.
With a gas mixing system (GMS) developed in our laboratory we created a gas mixture of
four substances. Adsorptive wall materials of four different compositions were exposed to this
gas mixture, consisting of 1-pentanol, hexanal, butyl acetate and n-decane. Aim of this study
was to scrutinize the ability of these samples to reduce the concentration of the supplied gas.
This capacity is expressed in the sorption flux F or area specific adsorption rate respectively.
The test was performed referring to a draft of ISO 16000-24.
The inhalation of 222Rn (radon) is one of the most important reasons for lung cancer, after smoking. Usually, the geological subsoil and the building ground are the dominant sources for enhanced indoor radon levels. Additionally, building materials can increase indoor radon concentrations when these materials contain higher contents of 226Ra (radium), especially in combination with low air exchange rates. For a realistic estimation of indoor radon
concentrations, it is helpful to carry out measurements of radon exhalation rates from relevant materials using emission test chambers. In Germany, it is aspired to limit the total indoor radon concentration to 100 Bq/m3, whereby building materials should contribute at most 20 Bq/m3. Within a project financed by the German Institute for Construction Technology (DIBt), a practical oriented measurement procedure of the radon exhalation of building materials in accordance to ISO 16000-9 was developed to have a means for the assessment of these materials with respect to their indoor use. Test chambers with different volumes were used. The tested materials were mainly used for wall constructions (e.g., bricks, light-weight concrete) and have known specific radium activities and radon exhalation rates.