GMR sensors are widely used in many industrial segments such as information technology, automotive, automation and production, and safety applications. Each area requires an adaption of the sensor arrangement in terms of size adaption and alignment with respect to the field source involved. This paper deals with an analysis of geometric sensor parameters and the arrangement of GMR sensors providing a design roadmap for non-destructive testing (NDT) applications. For this purpose we use an analytical model simulating the magnetic flux leakage (MFL) distribution of surface breaking defects and investigate the flux leakage signal as a function of various sensor parameters. Our calculations show both the influence of sensor length and height and that when detecting the magnetic flux leakage of µm sized defects a gradiometer base line of 250 µm leads to a signal strength loss of less than 10% in comparison with a magnetometer response. To validate the simulation results we finally performed measurements with a GMR magnetometer sensor on a test plate with artificial µm-range cracks. The differences between simulation and measurement are below 6%. We report on the routes for a GMR gradiometer design as a basis for the fabrication of NDT-adapted sensor arrays. The results are also helpful for the use of GMR in other application when it comes to measure positions, lengths, angles or electrical currents.
GMR sensors are increasingly used for magnetic surface inspection due to their high sensitivity and high spatial resolution. In case of simple planar or cylindrical shaped components, the GMR-based inspection procedure can be automated easily. We present GMR measurements of real fatigue cracks. In addition, we present a probe design using a local magnetization unit and commercially available GMR sensors. The design was carried out by means of finite-element method (FEM) simulations. Using the local probe we measured bearings containing artificial reference cracks of different depths and orientations. Cracks with a depth of 40 µm could be resolved with a signal-to-noise ratio better than 6. A further reduction of the measuring time can be obtained using a sensor array. For this purpose we present a study of the optimized size of the sensing GMR-layers for a NDE-adapted sensor array. The geometric sensor parameters were investigated through simulations of the magnetic flux leakage of surface cracks using an analytic model.
GMR sensors are increasingly used for magnetic surface inspection due to their high
sensitivity and high spatial resolution. In case of simple planar or cylindrical shaped
components, the GMR-based inspection procedure can be automated easily. In order to
reduce the inspection time we present a GMR-based NDT-system consisting of a yoke
and a coil as a local magnetization unit. This way the global magnetization step and, if
necessary, the corresponding demagnetization cycle can be avoided reducing the
number of working steps. Using a local probe we measured plates, bearings, and rails,
each of which containing real fatigue cracks and reference artificial cracks of different
depths and orientations. Cracks with a depth of 40 ìm could be resolved with a signalto-
noise ratio of about 20. A reduction of the measuring time can be obtained using a
sensor array. We present an optimized sensor array for nondestructive testing
application, where gradiometric arranged GMR layers were fabricated on a board with
up to 48 GMR sensors. Each sensor detects the vertical field gradient. In our example
the baseline was chosen to be 250 ìm which efficiently suppress external background
fields without losing sensitivity for the detection of surface breaking defects.