Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (34)
- Beitrag zu einem Tagungsband (19)
- Zeitschriftenartikel (18)
- Beitrag zu einem Sammelband (18)
- Posterpräsentation (5)
Schlagworte
- Zerstörungsfreie Prüfung (12)
- Radar (11)
- Radiografie (9)
- Strukturaufklärung (7)
- Videoskopie (7)
- Baudenkmäler (6)
- Image quality (5)
- Laminography (4)
- POD (4)
- Zuverlässigkeit (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (7)
- 8.5 Röntgenbildgebung (7)
- 7 Bauwerkssicherheit (4)
- 7.2 Ingenieurbau (4)
- 5 Werkstofftechnik (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 7.4 Baustofftechnologie (1)
- 8.0 Abteilungsleitung und andere (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
Eingeladener Vortrag
- nein (34)
The progress in X-ray detector electronics (sensitivity and speed) allows meanwhile fast single photon detection by a matrix detector. Combined photon counting and energy discrimination is implemented in the electronic circuit of each detector pixel. The company XCounter developed detectors based on CdTe single crystals, which can be tiled to larger areas and have a pixel size of 100ìm. The largest area available in beginning of 2014 is 50x75 mm². These detectors have very promising properties, which make them very suitable for NDT applications:
1. A CdTe attenuation layer of 750 µm thickness allows efficient X-ray detection up to ca. 300 keV. In counting mode only photon noise is important; no other detector noise sources need to be considered. There is no Offset signal without radiation.
2. Each of the detector pixels has two energy thresholds. These can be used for dual energy imaging for materials separation. Also the suppression of scattered radiation by energy thresholding will improve the image contrast sensitivity. First experiments will be presented which demonstrate the advantages of this new detector technology over the conventional charge integrating detectors.
A challenge is the development of a modified detector calibration procedure, which becomes critical at longer exposure times.
Tomographic visualization, inspection and control of thick pipe walls by restricted X-ray data
(2004)
Sandwich-Schalenstrukturen in situ charakterisiert mit Thermographie und Felddehnungsmessungen
(2018)
An der BAM wurde ein Schalenprüfstand entwickelt, mit dem typische Sandwichschalenstrukturen unter simulierter Betriebsbeanspruchung belastet werden können. Im mechanischen Ermüdungsversuch wurden in situ die Entstehung von Schäden in Schalenprüfkörpern mit Test-Imperfektionen mittels der passiven Thermographie und Felddehnungsmessungen verfolgt. Damit konnten der Zeitpunkt, der Schadensursprung und der Schadensfortschritt zerstörungsfrei bestimmt werden. Zudem wurden vergleichend Schalenprüfkörper mit Luftultraschall und der Röntgen-Laminographie untersucht. Im Rahmen eines BMWi-Forschungsvorhabens wurden die Schädigungsmechanismen evaluiert und Empfehlungen für die Praxis der Fertigung von Rotorblättern abgeleitet. In diesem Beitrag wird sich auf die Darstellung der ZfP-Verfahren und der ZfP-Ergebnisse konzentriert.
A comparative study on the performance of digital detector systems for high energy applications
(2014)
For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements.
Grouting defects, e.g. in post-tensioned structures or piped anchors may be identified by ultrasonic imaging. Since several years experiences are carried out with false color displayed phase values, which enable distinct localization of ungrouted regions.
In this contribution we report on progress in localizing grouting defects in tendon ducts, when they are only partly grouted and the unfilled part is not orientated into the direction of the measuring surface. This is frequently the case e.g. for box girder structures.
Düring the project specimens containing different types of grouting faults are investigated in Order to optimize measuring and evaluation techniques. A handheld linear array System (commercially available) is applied for fast 2D-measurement and subsequent phase sensitive 3D-imaging (new Software development).
In a large concrete wall specimen tendon ducts and real prestressing Systems containing grouting defects were built in. The ducts are partly covered by non prestressed reinforcement bars in order to investigate its disturbing influence. These included objects were investigated afterwards with the described methods. We report on large area measuring results, which were partly verified by y-radiography. In the frame of practical application results of measuring the position and extend of a blockade within a posttensioned structure are presen ted.
Zur Planung und Durchführung umfangreicher Sanierungs- und Umbaumaßnahmen im Pergamon-Museum Berlin bestand die Erfordernis einer Bauzustandsanalyse an antiken Baudenkmälern. Bestandsunterlagen waren unvollständig vorhanden bzw. fehlten. Hieraus ergab sich die Notwendigkeit des kombinierten Einsatzes zerstörungsfreier
Prüftechnik.
Zusammenfassung
Der Prototyp einer Flachröntgenröhre mit einer maximalen Röntgenenergie von 240kV (600W) und einer Brennfleckgröße von 0,4 * 0,4 mm nach DIN EN 12543 wird vorgestellt. Das Design dieser Flachröntgenröhre mit geringer Aufbauhöhe ist in Metall-Keramik-Technik ausgeführt. Die Beschleunigungsstrecke Katode-Anode ist senkrecht zur Haubenachse ausgeführt. Die Röhre ist als bipolares System aufgebaut. Kleine Durchmesser der Hochspannungskabel verringern das Gewicht und resultierende Kraftmomente bei der manuellen Manipulation sowie beim Verfahren in einem mechanisierten System. Der Targetwinkel beträgt 6° und bewirkt eine höhere Brillianz der Röntgenstrahlung. Die Geometrie des Strahlenaustrittsfensters (Emissionsfenster) ist in Fächerstrahlgeometrie zur tomografischen Prüfung ausgelegt.