The preparation and analysis of the oxygen mass fraction of three pure copper reference materials (BAM-379/1, BAM-379/2, BAM-379/3) intended for the calibration of spark emission spectrometry are described here. Data of homogeneity testing and round robin certification in collaboration with 12 independent laboratories from metalworking industry and research are reported. Problems with the establishment of traceability in this special case are discussed.
Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated.
Two types of copper samples, compact certified copper reference materials and calibration samples prepared from liquid doped, pressed copper powders, were studied in terms of accuracy of obtained calibration functions originating from infrared spark ablation. Additionally, corresponding particle size distributions of the aerosols from infrared spark ablation were recorded. It is shown that the differences in quantification results, originating from the two sets of calibration functions, could not mainly be ascribed to different particle size distributions of the two copper sample types. Possible other causes, as different ablation rates, parts of melting and differences of the chemical constitutions of the two sample types were explored.
For more than 110 years, BAM has been producing reference materials for a wide range of application fields. With the development of new analytical methods and new applications as well as continuously emerging more stringent requirements of laboratory accreditation with regard to quality control and metrological traceability, the demand and requirements for reference materials are increasing. This trend article gives an overview of general developments in the field of reference materials as well as developments in selected fields of application in which BAM is active. This includes inorganic and metal analysis, gas analysis, food and consumer products, and geological samples. In addition to these more traditional fields of application, developments in the areas of optical spectroscopy, particulary fluorescence methods, and nanomaterials are considered.
The special importance of the analysis of non-metals in high purity metals, which will serve as national standards for elemental analysis in Germany, is illustrated for oxygen and nitrogen. The typical range of the mass fraction of oxygen and nitrogen in these materials is below 10.MU.g/g, often close to 1.MU.g/g. The two methods applied at BAM for these measurements are classical carrier gas hot extraction (HE) and carrier gas hot extraction after activation with photons (PAA-HE). The approach, the methods and their advantages and limitations are discussed. Comparative results from the measurement of oxygen and nitrogen in Cu, Fe, Ga, Pb, Sn and W are presented. (author abst.)
The degree of equivalence within the participating national metrology institutes for the measurement results of the mass fractions of the analytes Cr, Cu, Fe, Mn and Zn in an aluminium alloy was assessed. This interlaboratory comité consultatif pour la quantité de matière key comparison (CCQM-K42) was organised as an activity of the Inorganic Analytical Working Group of CCQM. In total seven laboratories participated, six of them for all analytes. Measurands were the mass fractions of the analytes in a range of 0.05 and 0.2%. As an outcome the consistency of the results for all elements investigated was acceptable, hence satisfactory comparability was established. An aluminium based certified reference material—undisclosed to the analysts which one it was—was used as test sample. For the purpose of this study homogeneity was tested at BAM. Each laboratory was free to choose any analytical method they wanted to use for the analysis. Consequently various methods of measurement were employed: instrumental neutron activation analysis, X-ray fluorescence spectrometry (XRF) using fused cast-bead method combined with reconstitution technique, inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry. Metrological traceability of the measurement results to the SI unit had to be demonstrated. Therefore, methods such as spark OES or XRF (without fused cast-bead technique)—both of them being most important methods for the analysis of metals and alloys in industrial laboratories—could not be used in the frame of the key comparison.