Bisphenol A (BPA) is a common industrial chemical that is widely used as a monomer or additive in the production of polycarbonate plastics and other polymeric materials. The primary way of exposure to BPA for most people is assumed to be a direct con-tamination of food and water through use of containers, bottles, and other plastic stor-age. BPA has been identified as an important endocrine disrupting compound (EDC). It can interfere with hormonal activities like biosynthesis, metabolism and elimination of natural blood-borne hormones. Moreover, BPA can originate environmental problems. A spectrum of methods have been developed with the aim of determining BPA in water. Immunoassays appear to comply with sensitivity, rapidity, and low cost requirements for effective monitoring.
In this work a comparative analysis was conducted of the effect of temperature and the choice of buffers, as well as the substrate at various stages of an ELISA (enzyme-linked immunosorbent assay). The method has been optimized and has shown good repeatability and sensitivity. The results obtained from ELISA will be used as the basis for the development of a Lateral Flow ImmunoAssay (LFIA).
Bisphenol A (BPA) is a chemical that has been used in the production of plastics for more than 40 years. BPA released from bottles made of polycarbonates has been identified as a potential endocrine disrupting substance. Comprehensive research has been undertaken to test and verify its effect on animals and human beings.
Many methods have been proposed for the determination of BPA, in particular, gas and liquid chromatography. The main disadvantages of such approaches are the high cost of the equipment, the significant duration of an analysis, and difficulties in screening a large number of samples. Lateral Flow ImmunoAssay (LFIA) attributes are high throughput, high specificity and sensitivity, as well as low cost and simplicity.
An LFIA test strip was developed. This LFIA is based on anti-BPA antibodies (from mouse) conjugated with gold nanoparticles as the marker by passive absorption and covalent coupling, deposited in an elaborate pad. To form control and test zones, anti-mouse antibody and a BVA-BSA conjugate were spotted on the nitrocellulose membrane, respectively.
Negative samples are revealed by red lines both in the test and control zones, respectively, whereas positive samples produce a single red line only in the control zone. The measurement range is 0.05 – 23 μg/L, visually detected by the naked eye within 5 minutes. In addition, the intensities at the test line can be read by dedicated lateral flow readers (opTrilyzer® and Cube by opTricon, Berlin) for a more precise and documented determination.
An immunochromatographic assay for the determination of bisphenol a releases from plastic materials
(2018)
Background. The worldwide increase in the use of bisphenol A (BPA), a monomer commonly used to manufacture polycarbonate plastic products and the epoxy resins that line metal cans, has resulted in an increased human exposure because both products come in contact with food and beverages. Since BPA is an endocrine disruptor excessive exposure could affect human reproductive function. In response, various countries have adopted a range of measures, from voluntary reductions to outright bans of BPA in some products, mostly in baby bottles and containers for canned foods. Nonetheless, consumers would certainly appreciate a quick test for their own assessment of contaminations by bisphenol A.
Methods. An immunochromatographic test strip was developed. This lateral-flow immunoassay (LFIA) is based on anti-BPA antibodies (from mouse) conjugated with gold nanoparticles as the marker, deposited in an elaborate pad. To form control and test zones, anti-mouse antibody and a BPA-BSA conjugate were spotted on the nitrocellulose membrane, respectively.
Results. Negative samples are revealed by red lines both in the test and control zones, respectively, whereas positive samples produce a single red line only in the control zone. The limit of detection (LOD) was found to be 0.05 µg/l, visually detected by the naked eye within 5 minutes. In addition, the intensities at the test line can be read by dedicated lateral flow readers (opTrilyzer® and Cube by opTricon, Berlin) for a more precise and documented determination.
Conclusion. Pregnancy-test like strips in combination with hand-held readers provide a simple and versatile tool to determine the presence of bisphenol A quantitatively, making it a very attractive analytical approach especially for on-site applications at critical points, such as environmental analysis, consumer protection, and materials testing.
Diclofenac (DCF) is a non-steroidal anti-inflammatory drug (NSAID) with analgetic, anti-inflammatory, and antipyretic properties. The mechanism of action of diclofenac, like that of other NSAIDs, involves inhibition of cyclooxygenase (COX-1 and COX-2). Another pharmacological effect is preventing of prostaglandin synthesis in vitro. Prostaglandins are mediators of inflammation, because diclofenac is an inhibitor of prostaglandin synthesis.
A method has been developed to analyse for diclofenac (DCF) in the milk.
Bisphenol A (BPA), a monomer commonly used to manufacture polycarbonate plastic products and the epoxy resins that line metal cans, has resulted in an increased human exposure because both products come in contact with food and beverages. Since BPA is an endocrine disruptor excessive exposure could affect human reproductive function. In response, various countries have adopted a range of measures, from voluntary reductions to outright bans of BPA in some products, mostly in baby bottles and containers for canned foods. Pregnancy-test like strips in combination with hand-held readers provide a simple and versatile tool to determine the presence of bisphenol A quantitatively, making it a very attractive analytical approach especially for on-site applications at critical points, such as environmental analysis, consumer protection, and materials testing.
BPA is a chemical commonly used in the production of polymer-based materials that can have detrimental effects on the thyroid gland and impact human reproductive health. Various expensive methods, such as liquid and gas chromatography, have been suggested for detecting BPA.
The fluorescence polarization immunoassay (FPIA) is an inexpensive and efficient homogeneous mix-and-read method that allows for high-throughput screening. FPIA offers high specificity and sensitivity and can be carried out in a single phase within a timeframe of 20–30 min. In this study, new tracer molecules were designed that linked the fluorescein fluorophore with and without a spacer to the bisphenol A moiety. To assess the influence of the C6 spacer on the sensitivity of an assay based on the respective antibody, hapten–protein conjugates were synthesized and assessed for performance in an ELISA setup, and this resulted in a highly sensitive assay with a detection limit of 0.05 µg/L. The lowest limit of detection was reached by employing the spacer derivate in the FPIA and was 1.0 µg/L, working range from 2 to 155 µg/L. The validation of the methods was conducted using actual samples compared to LC–MS/MS, which served as the reference method. The FPIA and ELISA both demonstrated satisfactory concordance.
A combination of TLC-bioautography, MALDI-TOF-MS and LC–MS/MS methods was used to identify flavonoids with anti-α-amylase activity in extracts of Lathyrus pratensis L. (herb), L. polyphillus L. (fruits), Thermopsis lanceolata R. Br. (herb) and S. japonica L. (buds). After the TLC-autobiography assay, substances with anti-amylase activity were identified by MALDI-TOF-MS followed by confirmation of the result by LC–MS/MS. Results of the study revealed that the flavonoids apigenin, luteolin, formononetin, genistein and kaempferol display marked anti-α-amylase activity. Formononetin showed the largest activity. Compared with LC–MS/MS, MALDI-TOF-MS is a quick and convenient method; results can be obtained within minutes; and only minor sample amounts are required which allows us to analyse mixtures of substances without preliminary separation. However, the inability to distinguish between isomers is the main limitation of the method.