Protein immobilization for the functionalization of particles is used in various applications, including biosensors, lateral-flow immunoassays (LFIA), bead-based assays, and others. Common methods for the quantification of bound protein are measuring protein in the supernatant before and after coating and calculating the difference. This popular approach has the potential for a significant overestimation of the amount of immobilized protein since layers not directly bound to the surface (soft protein corona) are usually lost during washing and handling. Only the layer directly bound to the surface (hard corona) can be used in subsequent assays. A simplified amino acid analysis method based on acidic hydrolysis and RP-HPLC-FLD of tyrosine and phenylalanine (aromatic amino acid analysis, AAAA) is proposed to directly quantify protein bound to the surface of gold nano- and latex microparticles. The results are compared with indirect methods such as colorimetric protein assays, such as Bradford, bicinchoninic acid (BCA), as well as AAAA of the supernatant. For both particle types, these indirect quantification techniques show a protein overestimation of up to 1700% compared to the direct AAAA measurements. In addition, protein coating on latex particles was performed both passively through adsorption and covalently through EDC/sulfo-NHS chemistry. Our results showed no difference between the immobilization methodologies. This finding suggests that usual protein determination methods are no unambiguous proof of a covalent conjugation on particles or beads.
One of the most important chemicals used in the production of polymer plastics and coatings is bisphenol A. However, despite the large number of studies on the toxicity and hormonal activity of BPA, there are still open questions and thus considerable media attention regarding BPA toxicity. Hence, it is necessary to develop a sensitive, simple, cost-efficient, specific, portable, and rapid method for monitoring bisphenol A and for high sample throughput and on-site screening analysis. Lateral flow immunoassays have potential as rapid tests for on-site screening. To meet sensitivity criteria, they must be carefully optimized. A latex microparticle-based LFIA for detection of BPA was developed. The sensitivity of the assay was improved by non-contact printing of spot grids as the control and test lines with careful parameter optimization. Results of the test could be visually evaluated within 10 min with a visual cut-off of 10 µg/L (vLOD). Alternatively, photographs were taken, and image analysis performed to set up a calibration, which allowed for a calculated limit of detection (cLOD) of 0.14 µg/L. The method was validated for thermal paper samples against ELISA and LC–MS/MS as reference methods, showing good agreement with both methods
Introduction
Aflatoxin B1 (AFB1) is a toxic low‐molecular‐weight secondary metabolite of Aspergillus flavus and A. parasiticus. AFB1 was classified as a Group I carcinogen by the World Health Organisation for Research on Cancer in 1993. AFB1 is an unavoidable natural contaminant of some herbal medicine, able to cause serious health issues for humans consuming the related medicine.
Objective
Therefore, this study aimed to develop an efficient fluorescence polarisation immunoassay (FPIA) and a rapid, low‐cost, and easy‐to‐use membrane‐based flow‐through immunoassay (MBA) for determination of AFB1 in herbal medicine Origanum vulgare L., Rubus idaeus L., Urtica dioica L. and Sorbus aucuparia L.
Results
A cut‐off level of the developed MBA was 0.8 ppb. Validation of the developed test was performed with blank and spiked samples. Using three naturally contaminated or three artificially spiked samples. The FPIA showed a linear working range of 8.6 to 64 ppb, and a half maximal inhibitory concentration (IC50) of 24 ppb.
Conclusion
The results were in good correlation with the enzymelinked immunosorbent assay (ELISA) results (the IC50 0.1 ppb). Both the sample preparation and analysis are simple, cost‐effective and easy to perform on‐site in non‐laboratory environments. Liquid chromatography with tandem mass spectrometry (LC‐MS/MS) was used as a confirmatory technique.
A lateral flow immunoassay (LFIA) using latex particles labeled with antibody to BSAclarithromycin (CLA) was developed for the rapid simultaneous group determination of six macrolide antibiotics. Optimization of antigen spotting on the membrane and latex probe loading allowed improving visual detectability (vLOD) 100 times, which was 1, 1, 10, 10, 50, and 1000 ng/mL for CLA, roxithromycin, erythromycin, dirithromycin, azithromycin, and oleandomycin in buffer, respectively. The calculated limits of instrumental detection (cLOD) were respectively 0.12, 0.15, 1.4, 2.1, 2.4, and 3.3 ng/mL. To avoid a strong influence of breast milk of a very diverse and variable composition, a sample pretreatment is proposed. The six macrolides mentioned can be visually detected in breast milk after 20 minutes pretreatment at concentrations of 10-1000 ng / ml or instrumentally with cLOD of 4.0, 2.5, 30, 42, 42 and 180 ng/mL. The recovery rate from the spiked samples carried out using a strip scanner device ranged from 71% to 110%, and precision expressed as relative standard deviation was between 3-14%. The described rapid on-site diagnostic assay format can be useful for monitoring the content of antibiotics in breast milk during macrolide treatment to ensure safe breastfeeding of infants.
Mycotoxins are toxic secondary metabolites produced by filamentous fungi. The contamination of mycotoxins in food and feed products has been recognized to be an important safety issue for human and animal health. In the context of food safety, medical herbs nowadays are also considered as potential source of mycotoxins. Considering that mycotoxins are generally stable compounds and could not be destroyed completely during food-processing operations, prevention of contamination is identified as main issue.
Currently, biochemical, and immunochemical methods based on the use of antibodies as a specific recognition bioreagents are increasingly found to be applied in screening. Along with good common enzyme linked immunosorbent assay (ELISA), more and more widely used method is fluorescence polarization immunoassay (FPIA). These methods help to monitor of many toxic substances in large number of samples and carried out quickly, easily, cheaply, and give good results in quantifying the one or more substances. That is why the use of immunochemical methods of analysis, such as ELISA and FPIA, is the most promising for solving this problem.
Thus, the aim of our work is to optimize the determination of mycotoxins by ELISA and FPIA in medical herbs. We selected antibodies and a tracer for the FPIA, then we constructed obtained a calibration curve and determined the sensitivity of this method for the samples in aqueous media. Then, the optimal sample preparation was elaborated: for spiked nuts samples were selected and prepared and a calibration curve was obtained with respect to the matrix effect. After that, the analysis of spiked nuts samples was performed by ELISA and FPIA and the sensitivity of both methods was compared.
Ideen nah am Leben
(2019)
Pharmacologically active compounds are often detected in wastewater and surface waters. The nonsteroidal anti-inflammatory drug diclofenac (DCF) was included in the European watch list of substances that requires its environmental monitoring in the member states. DCF may harmfully influence the ecosystem already at concentrations ≤ 1 μg L−1. The fast and easy quantification of DCF is becoming a subject of global importance. Fluorescence polarization immunoassay (FPIA) is a homogeneous mix-and-read method which does not require the immobilization of reagents. FPIA can be performed in one phase within 20–30 min, making it possible to analyse wastewater without any complicated pre-treatment. In this study, new tracermolecules with different structures, linking fluorophores to derivatives of the analyte, were synthesized, three homologous tracers based on DCF, two including a C6 spacer, and one heterologous tracer derived from 5-hydroxy-DCF. The tracer molecules were thoroughly assessed for performance. Regarding sensitivity of the FPIA, the lowest limit of detection reached was 2.0 μg L−1 with a working range up to 870 μg L−1. The method was validated for real wastewater samples against LC-MS/MS as reference method with good agreement of both methods.
Background. Aflatoxin B1 (AFB1) is a toxic low-molecular-weight secondary fungal metabolite produced mainly by Aspergillus flavus and Aspergillus parasiticus not only at pre-harvest time but also at post-harvest stages including storage. AFB1 was classified as a Group I carcinogen by the World Health Organization for Research on Cancer in 1993. AFB1 is able to naturally contaminate medicinal plants and therefore causing serious health issues for humans consuming the related medicine. This study aimed to develop an efficient fluorescence polarization immunoassay (FPIA) and for the first time a rapid (5-10 min), low-cost, and simple membrane-based flow-through immunoassay (MBA) for determination of AFB1 in medical herbs based on a monoclonal antibody.
Methods. Two different techniques for AFB1detection in medical herbs (Herba Orígani vulgáris, Folia Urticae, Fructus Rubi idaei) were developed and compared, namely an easy-to-use semi-quantitative flow-through membrane-based enzyme immunoassay (MBA), and a homogeneous method which needs no separation or washing steps (assay time 10 min), a quantitative fluorescence polarization immunoassay (FPIA).
Results. A cut-off level of the developed MBA can vary wide from 0.8 ppb to 1 ppb. The FPIA method showed a linear working range of 8.6 ppb to 64 ppb, IC50 of FPIA is 24 ppb. The results were in good correlation with the ELISA results (IC50 = 0.1 ppb). LC–MS/MS was used to confirm the results, too.
Conclusion. MBA can be used for a quick on-site AFB1 detection in medical herbs (Herba Orígani vulgáris (Oríganum vulgáre), Folia Urticae (Urtíca dióica), Fructus Rubi idaei (Rúbus idáeus)), the developed test does not require special equipment and is not time-consuming (5-10min), includes several simple steps and can be performed directly on-site. The major advantages of the developed FPIA are its simplicity and suitability for a rapid screening of a large number of samples.
Bisphenol A (BPA) is a chemical that has been used in the production of plastics for more than 40 years. BPA released from bottles made of polycarbonates has been identified as a potential endocrine disrupting substance. Comprehensive research has been undertaken to test and verify its effect on animals and human beings.
Many methods have been proposed for the determination of BPA, in particular, gas and liquid chromatography. The main disadvantages of such approaches are the high cost of the equipment, the significant duration of an analysis, and difficulties in screening a large number of samples. Lateral Flow ImmunoAssay (LFIA) attributes are high throughput, high specificity and sensitivity, as well as low cost and simplicity.
An LFIA test strip was developed. This LFIA is based on anti-BPA antibodies (from mouse) conjugated with gold nanoparticles as the marker by passive absorption and covalent coupling, deposited in an elaborate pad. To form control and test zones, anti-mouse antibody and a BVA-BSA conjugate were spotted on the nitrocellulose membrane, respectively.
Negative samples are revealed by red lines both in the test and control zones, respectively, whereas positive samples produce a single red line only in the control zone. The measurement range is 0.05 – 23 μg/L, visually detected by the naked eye within 5 minutes. In addition, the intensities at the test line can be read by dedicated lateral flow readers (opTrilyzer® and Cube by opTricon, Berlin) for a more precise and documented determination.