Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (13)
- Deutsch (12)
- Französisch (1)
Schlagworte
- Corrosion (6)
- BetoScan (3)
- Betonflächendiagnose (3)
- Betoninstandsetzung (3)
- Concrete (3)
- Diagnosis (3)
- Korrosion (3)
- Reinforcement corrosion (3)
- Scanner (3)
- ZfP im Bauwesen (3)
- Cathodic protection (2)
- Hüttensandmehl (2)
- Kathodischer Korrosionsschutz (2)
- Non destructive testing (2)
- Stahlbeton (2)
- Steel (2)
- Sulfid (2)
- Surface protection system (2)
- Alkali-Kieselsäure Reaktion (1)
- Alkali-activated materials (1)
- Anticorrosion (1)
- Automated testing (1)
- Automation (1)
- Beschichtung (1)
- Beton (1)
- Betonstahl (1)
- Betoscan (1)
- Bewehrung (1)
- Bridge management (1)
- Carbonation (1)
- Chlorid-induced corrosion (1)
- Chloride Induced Corrosion (1)
- Chloride ingress (1)
- Chlorinduzierte Korrosion (1)
- Corrosion costs (1)
- Corrosion protection (1)
- Coûts de la corrosion (1)
- DIN EN 1504 (1)
- Damage analysis (1)
- Damage assessment (1)
- Design for durability (1)
- Durability (1)
- Electrochemical methods (1)
- Embedded Sensors (1)
- Europäische Normungsarbeit (1)
- FEM-modelling (1)
- Freezethaw resistance (1)
- Galvanische Anoden (1)
- Hydrophobic treatment (1)
- Inhomogeneity (1)
- Inspection (1)
- Instandsetzungsmörtel (1)
- Integrated Monitoring System (1)
- Interfacial transition zone (1)
- Ionen Transport (1)
- KKS (1)
- LIBS (1)
- Long time effects of cathodic polarisation (1)
- Macrocell corrosion model (1)
- Maintenance (1)
- Messunsicherheit (1)
- NDT (1)
- Oberflächenschutzsystem (1)
- Oberflächenschutzsysteme (1)
- Onsite scanner (1)
- Potential mapping (1)
- Preventive strategies (1)
- Protection (1)
- Radar (1)
- Reinforced concrete (1)
- Reinforcement (1)
- Reinforcing steel (1)
- Repair (1)
- Schlacke (1)
- Sensors (1)
- Sprayed zinc layer (1)
- Stahlkorrosion (1)
- Steel corrrosion (1)
- Steel in concrete (1)
- Steel-concrete interface (1)
- Stratégies deprévention (1)
- Tausalz (1)
- Thermische Spritzverzinkung (1)
- Ultraschallecho (1)
- Ultrasonic echo (1)
- Validierung (1)
- Variability (1)
- Water uptake (1)
- Weathering (1)
- Zement (1)
- Zerstörungsfreie Prüfung im Bauwesen (1)
- Zuverlässigkeit (1)
Organisationseinheit der BAM
Alkali-aktivierte Hüttensandbetone – CO2-reduzierte Bindemittel mit hohem Korrosionsschutzpotential
(2023)
Durch den Ersatz von Portlandzement können alkali-aktivierte Bindemittel einen bedeutenden Beitrag zur Verringerung der durch die Zementklinkerherstellung verursachten CO2-Emissionen leisten. Für die Verwendung von alkali-aktivierten Bindemitteln in Stahlbetonkonstruktionen, die Chloriden oder Carbonatisierung ausgesetzt sind, ist die Fähigkeit des Stahls, den passiven Zustand zu erreichen und aufrechtzuerhalten, von großer Bedeutung. Die Prozesse der Deckschichtbildung von Stahl in alkali-aktivierten Materialien unterscheiden sich jedoch zum Teil grundlegend von denen in Portlandzementen. Alkali-aktivierte Hüttensandbetone weisen gute technische Eigenschaften auf, bisher fehlen jedoch grundlegende Kenntnisse bzgl. ihrer schützenden Wirkung bei korrosiven Angriffen. Dies ist vor allem auf ihre sulfidhaltige Porenlösung zurückzuführen, welche die elektrochemischen Eigenschaften der Stahloberfläche beeinflusst und die Verwendung herkömmlicher Bewertungsmaßstäbe erschwert. Es werden erste Ergebnisse eines DFG-Forschungsprojektes vorgestellt, in dem das Passivierungsverhalten von Stahl in alkali-aktivierten Hüttensandmörteln unterschiedlicher Zusammensetzungen sowie in Mörteln auf Basis hüttensandhaltiger Normzemente untersucht wird. Über einen Zeitraum von mindestens 28 Tagen werden an Zylinderprüfkörpern im 3-Elektroden-Aufbau das Ruhepotential sowie die Polarisationswiderstände der Stahlelektroden ermittelt.
Application of electrochemical methods for studying steel corrosion in alkali-activated materials
(2023)
Alkali-activated materials (AAMs) are binders that can complement and partially substitute the current use of conventional cement. However, the present knowledge about how AAMs protect steel reinforcement in concrete elements is incomplete, and uncertainties exist regarding the application of electrochemical methods to investigate this issue. The present review by EFC WP11-Task Force ‘Corrosion of steel in alkali-activated materials’ demonstrates that important differences exist between AAMs and Portland cement, and between different classes of AAMs, which are mainly caused by differing pore solution compositions, and which affect the outcomes of electrochemical measurements. The high sulfide concentrations in blast furnace slag-based AAMs lead to distinct anodic polarisation curves, unusually low open circuit potentials, and low polarisation resistances, which might be incorrectly interpreted as indicating active corrosion of steel reinforcement. No systematic study of the influence of the steel–concrete interface on the susceptibility of steel to corrosion in AAMs is available. Less common electrochemical methods present an opportunity for future progress in the field.
BETOSCAN - An instrumented mobile robot system for the diagnosis of reinforced concrete floors
(2009)
A global transition towards more sustainable, affordable and reliable energy systems is being stimulated by the Paris Agreement and the United Nation's 2030 Agenda for Sustainable Development. This poses a challenge for the corrosion industry, as building climate‐resilient energy systems and infrastructures brings with it a long‐term direction, so as a result the long‐term behaviour of structural materials (mainly metals and alloys) becomes a major prospect. With this in mind “Corrosion Challenges Towards a Sustainable Society” presents a series of cases showing the importance of corrosion protection of metals and alloys in the development of energy production to further understand the science of corrosion, and bring the need for research and the consequences of corrosion into public and political focus. This includes emphasis on the limitation of greenhouse gas emissions, on the lifetime of infrastructures, implants, cultural heritage artefacts, and a variety of other topics.
In einer Artikelserie stellen wir die neue Instandhaltungs-Richtlinie des Deutschen Ausschusses für Stahlbeton (DAfStb) vor. Im zweiten Teil geht es um Betonersatz- und Oberflächenschutzsysteme sowie Rissfüllstoffe. Es werden als Folge des EuGH-Urteils vom Oktober 2014 zukünftig keine Anforderungen an Bauprodukte mit dem Nachweis über allgemeine bauaufsichtliche Prüfzeugnisse gestellt. Stattdessen werden auf Basis der Anforderungen individueller Bauwerke notwendige Merkmale von Bauprodukten für die Instandsetzung definiert. Außerdem wird Teil 3 der neuen Instandhaltungs-Richtlinie "Ausführung der Instandsetzung und Überwachung" vorgestellt. Neu ist hier die Einführung von Überwachungsklassen, die sich aus der Art des instand zu setzenden Betonbauteils (standsicherheitsrelevant oder nicht) und der auszuführenden Arbeiten ergeben, zum Beispiel Instandsetzung oder Verstärkung. Am Ende dieses Artikels wird kurz der 4. Teil der neuen Instandhaltungs-Richtlinie erläutert.