It is a latent wish of any SEM/EDS (scanning electron microscope with an energy dispersive spectrometer) analyst to “see more” of the analyzed specimen, i.e. to improve the existing analytical figures of merit.
One key issue are the relatively poor limits of detection (not below 0.1 mass-%) provided by energy dispersive X-ray spectrometry (EDX) with the conventional electron excitation (ED-EPMA). This is a consequence of relatively low peak-to-background ratios and reduced energy resolution when compared to wavelength dispersive spectrometry (WD-EPMA). Recent technological developments make possible to equip the SEM with a wavelength dispersive spectrometer (WDS), so that
significantly better energy resolution can be attained. Also a relative new product that can be easily attached to a SEM/EDS system is a micro-focus X-ray source. Hence, it is possible to perform (micro-focus) X-ray fluorescence spectrometry (μ-XRF) and take advantage of the enhanced peak-to-background ratios (well suited for trace analysis). However, there are also some disadvantages: an increased measurement time and excitation with a high current in the 10s of nA range are usually required for WDS. μ-XRF provides more bulk information and poor limits of detection for light elements. By combining the advantages of these analytical techniques “seeing more” becomes possible.
X-ray scattering may contribute significantly to the spectral background of X-ray fluorescence (XRF) spectra. Based on metrological measurements carried out with a scanning electron microscope (SEM) having attached a well characterised X-ray source (polychromatic X-ray tube) and a calibrated energy dispersive X-ray spectrometer (EDS) the accuracy of a physical model for X-ray scattering is systematically evaluated for representative samples. The knowledge of the X-ray spectrometer efficiency, but also of the spectrometer response functions makes it possible to define a physical spectral background of XRF spectra. Background subtraction relying on purely mathematical procedures is state-of-the-art. The results produced by the analytical model are at least as reliable as those obtained by Monte-Carlo simulations, even without considering the very challenging contribution of multiple scattering. Special attention has been paid to Compton broadening. Relevant applications of the implementation of the analytical model presented in this paper are the prediction of the limits of detection for particular cases or the determination of the transmission of X-ray polycapillary lenses.
The high specificity of the coherent (Rayleigh), as well as incoherent (Compton) X-ray scattering to the mean atomic number of a specimen to be analyzed by X-ray fluorescence (XRF), is exploited to gain more information on the chemical composition. Concretely, the evaluation of the Compton-to-Rayleigh intensity ratio from XRF spectra and its relation to the average atomic number of reference materials via a calibration curve can reveal valuable information on the elemental composition complementary to that obtained from the reference-free XRF analysis. Particularly for matrices of lower mean atomic numbers, the sensitivity of the approach is so high that it can be easily distinguished between specimens of mean atomic numbers differing from each other by 0.1. Hence, the content of light elements which are invisible for XRF, particularly hydrogen, or of heavier impurities/additives in light materials can be calculated 'by difference' from the scattering calibration curve. The excellent agreement between such an experimental, empirical calibration curve and a synthetically generated one, on the basis of a reliable physical model for the X-ray scattering, is also demonstrated. Thus, the feasibility of the approach for given experimental conditions and particular analytical questions can be tested prior to experiments with reference materials. For the present work a microfocus X-ray source attached on an SEM/EDX (scanning electron microscopy/energy dispersive X-ray spectroscopy) system was used so that the Compton-to-Rayleigh intensity ratio could be acquired with EDX spectral data for improved analysis of the elemental composition.
An inter-laboratory comparison organized as a pilot study (PS) has been performed under the umbrella of the Consultative Committee for Amount of Substance – Metrology in Chemistry (CCQM) / Surface Analysis Working Group (SAWG) with the objective to compare k-values measured with Electron Probe X-ray Microanalysis (EPMA) for copper-gold alloys. The k-value, defined as the ratio of the Xray photon intensity of an X-ray characteristic line of the unknown sample to the corresponding one in the reference material, is a rough estimate of the mass fraction of the respective element. Basically, the mass fractions can be calculated from the k-values after applying a matrix correction procedure, which includes empirical approaches, so that traceability gets lost. Due to its physical, measurable nature, the k-value has been selected in the present PS as the primary measurand. The mass fraction has been set as the secondary (derived) measurand. Both EDX and WDX have been employed. The WDX results and the overall comparability between the k-values obtained by EDX and WDX are still in progress.