A microfocus X-ray source mounted on the analysis chamber of an SEM was used to excite X-ray fluorescence spectra and to detect chemical elements with concentrations below the detection limit of the electron-excited X-ray spectra conventionally measured with SEM/EDS. An aluminium alloy and a hard material ceramics were analysed as representative examples. It is demonstrated that the combination of the three analytical methods: (1) SEM imaging for surface morphology characterisation; (2) electron-excited X-ray spectroscopy with its high spatial resolution for element analysis of inclusions or precipitates; and (3) X-ray fluorescence for the detection of elements with concentrations below 0.1 mass% considerably improves the performance of SEM/EDX analyses.
Checking the performance of energy dispersive X-ray spectrometers as well as validation of the results obtained with energy dispersive X-ray spectrometry (EDX) at a scanning electron microscope (SEM) involve the use of (certified) reference and dedicated test materials. This paper gives an overview on the test materials mostly employed by SEM/EDX users and accredited laboratories as well as on those recommended in international standards. The new BAM reference material EDS-CRM, which is currently in the process of certification, is specifically designed for the characterization of EDS systems at a SEM through calibration of the spectrometer efficiency in analytical laboratories in a simple manner. The certification of the spectra by means of a reference EDS is described. The focus is on the traceability of EDS efficiency which is ensured by measurements of the absolute detection efficiency of silicon drift detectors (SDD) and Si(Li) detectors at the laboratory of the PTB using the electron storage ring BESSY II as a primary X-ray source standard. A new test material in development at BAM for testing the performance of an EDS in the energy range below 1 keV is also briefly presented.
The high specificity of the coherent (Rayleigh), as well as incoherent (Compton) X-ray scattering to the mean atomic number of a specimen to be analyzed by X-ray fluorescence (XRF), is exploited to gain more information on the chemical composition. Concretely, the evaluation of the Compton-to-Rayleigh intensity ratio from XRF spectra and its relation to the average atomic number of reference materials via a calibration curve can reveal valuable information on the elemental composition complementary to that obtained from the reference-free XRF analysis. Particularly for matrices of lower mean atomic numbers, the sensitivity of the approach is so high that it can be easily distinguished between specimens of mean atomic numbers differing from each other by 0.1. Hence, the content of light elements which are invisible for XRF, particularly hydrogen, or of heavier impurities/additives in light materials can be calculated 'by difference' from the scattering calibration curve. The excellent agreement between such an experimental, empirical calibration curve and a synthetically generated one, on the basis of a reliable physical model for the X-ray scattering, is also demonstrated. Thus, the feasibility of the approach for given experimental conditions and particular analytical questions can be tested prior to experiments with reference materials. For the present work a microfocus X-ray source attached on an SEM/EDX (scanning electron microscopy/energy dispersive X-ray spectroscopy) system was used so that the Compton-to-Rayleigh intensity ratio could be acquired with EDX spectral data for improved analysis of the elemental composition.