Standards for the application of flash thermography as well as of lock-in thermography are urgently required.
Both methods are applied more and more often in research and industry, but still extensive validation procedures are required for each individual application. In this paper, the results of two research projects concerning the validation and standardisation of both methods are presented. This includes results of a detailed study of the influence of measurements parameters on flash thermography, of the comparison of the lateral resolution obtained with flash and lock-in thermography and the description of a draft standard for flash thermography.
Low-velocity impact damages were monitored in-situ using an infrared camera before, during and after Impact load. Thermal images were recorded as a function of time at the front side (impact) as well as at the rear side of the plates using a high frame rate. In CFRP and GFRP specimens with different thicknesses and made of various types of fibers and matrix materials, different kind of damages were observed. The sizes of the heated areas being related to the damages and the amount of energy dissipated into heat was determined quantitatively as a function of impact energy and are a measure of the resistance of the different materials against impact load.
We present a first direct measurement of the temperature during milling combined with in situ Raman spectroscopy monitoring. The data reveal a low temperature increase due to the mechanical impact and clear temperature increases as a consequence of the reaction heat. Based on the data, temperature rises as postulated in the magma plasma and hot spot theory can be excluded for soft matter milling syntheses.
In diesem Beitrag werden zerstörungsfreie Untersuchungen mittels aktiver Thermografie an Probekörpern aus CFK und GFK mit unterschiedlichen künstlichen Fehlstellen vorgestellt. Dabei wird die zeitliche und örtliche Temperaturverteilung nach der Erwärmung mit Blitzlampen oder mit einem Infrarot-Strahler mit einer Infrarot-Kamera erfasst. Zur späteren Rekonstruktion der Messdaten wurde ein numerisches Modell entwickelt. Dazu war die Bestimmung der thermophysikalischen und optischen Materialeigenschaften erforderlich, was in diesem Beitrag ebenfalls beschrieben wird. Die Ergebnisse der numerischen Modellierung werden mit den experimentellen Untersuchungen der aktiven Thermografie verglichen. Weiterhin werden die experimentellen Untersuchungen hinsichtlich der beiden Materialsysteme CFK und GFK und unter Berücksichtigung der Teiltransparenz des GFK-Materials sowie der unterschiedlichen Anregungsquellen bewertet.
In diesem Beitrag werden zerstörungsfreie Untersuchungen mittels aktiver Thermografie an Probekörpern aus CFK und GFK mit unterschiedlichen künstlichen Fehlstellen vorgestellt. Dabei wird die zeitliche und örtliche Temperaturverteilung nach Erwärmung mit Blitzlampen oder mit einem Infrarot-Strahler mit einer Infrarot-Kamera erfasst. Zur Rekonstruktion der Messdaten wurde ein numerisches Modell entwickelt. Dazu war die Bestimmung der thermischen und optischen Materialeigenschaften erforderlich.
Im EMRP-Projekt VITCEA werden komplementäre ZFP-Verfahren zur Prüfung von Faserverbundwerkstoffen weiterentwickelt und validiert. In diesem Beitrag werden Ergebnisse verschiedener Techniken der aktiven Thermografie und des Ultraschalls vorgestellt. Die Nachweisempfindlichkeiten bezüglich künstlicher und natürlicher Fehler mit unterschiedlichen lateralen Ausdehnungen und in verschiedenen Tiefen werden miteinander verglichen.
The increased use of fibre reinforced plastic (FRP) composites for improved efficiency and reliability in energy related applications, e.g. wind and marine turbine blades, nacelles, oil and gas flexible risers, also increases the demand for innovative non-destructive testing technologies. In this contribution, results concerning the characterisation of CFRP and GFRP during and after quasi-static tensile loading are presented. It includes the measurement of optical properties in the infrared spectral range, tensile loading tests with the observation of the temperature distribution at one or both sides of the specimens using an infrared camera for the preparation and monitoring of intended natural defects, and active thermography inspections after tensile loading. It is shown that the defect preparation was successful. Thermographic monitoring during and active thermography testing after tensile loading enable the detection of the lateral extend of the generated defects. Differences between CFRP and GFRP materials are discussed.
Impact damages and delaminations in fibre-reinforced composites (FRC) might not be visible at the surface, but could have an influence on the resistance and on the long-term behaviour of the component. Therefore, and especially for safety relevant structures, non-destructive methods are required for the assessment of such damages.
Active thermography methods are suitable to characterize damages after loading using different kind of excitation techniques and various configurations of infrared (IR) camera and heating sources. Here, flash lamps, impulse excitation with infrared radiator and lock-in technique with halogen lamps or widened laser beams are suited. In addition, non-optical sources like sonotrodes (requiring direct contact to the structure) or induction generators (only suited for carbon fibre reinforced polymer (CFRP) structures) could be applied as well. For the investigation of the evolution of the damage during the impact, passive thermography can be applied in-situ. Elastic and plastic deformations alter the temperature of the structure and thus the temperature on the surface.
In this contribution, at first the general principles of quantitative defect characterisation in FRC using active thermography with flash, impulse and lock-in excitation are described. Optical and thermal properties of the FRC material and its anisotropy are considered. Results of phase differences obtained at flat bottom holes with flash and lock-in thermography are compared for qualifying both methods for quantitative defect characterization. Secondly, the damage evolution of CFRP and GFRP structures under impact load and static tensile loading is described. The spatial and temporal evolution of the surface temperature enables us to distinguish matrix cracks or fibre-matrix separation from delaminations between the layers. Afterwards, all results for loading defects, obtained by passive and active thermography, are compared with each other. Fig. 1 and 2 show the difference of passive and flash thermography obtained at impact and tensile loaded CFRP plates, respectively. As one purpose of these investigations is the development of standards within national (DIN) and European (CEN) standardisation bodies, new draft and final standards are presented and further needs are discussed at the end of the presentation.
Das Ziel des Forschungsvorhabens „Zerstörungsfreie Ortung von Gefügestörungen in Betonbodenplatten“ bestand in der Entwicklung eines Untersuchungskonzepts zur sicheren Ortung und Erfassung von Gefügestörungen in einseitig zugänglichen Betonplatten durch den kombinierten Einsatz verschiedener zerstörungsfreier Prüfverfahren. Hierfür wurde die Leistungsfähigkeit der folgenden Messverfahren hinsichtlich ihrer Aussageschärfe, Anwendungsgrenzen und Messgeschwindigkeit bei praxisnahen Randbedingungen untersucht:
- Impakt-Echo, manuelle Impaktauslösung
- Impakt-Echo, automatisierte Impaktauslösung
- Ultraschall-Echo mit multistatischem Array
- Impuls-Thermografie
- Radar
Als Versuchskörper dienten sechs liegend hergestellte Betonplatten der Abmessungen 200/200/30 cm aus zwei verschiedenen Betongüten und mit unterschiedlichem Bewehrungsgehalt (Bewehrungsgrade 0 %, 0 ,9 %, 2 ,6 %), von denen vier Platten auf trockenem und zwei Platten auf ständig nass gehaltenem Sand gelagert waren. Alle sechs Platten enthielten jeweils dieselben künstlich eingebrachten Fehlstellen: vier quadratische Kiesnester in unterschiedlicher Tiefe mit Kantenlängen zwischen 10 und 15 cm sowie drei oberflächennahe Hohlstellen (Ø 4/6/8 cm). Zur Erfassung eines möglichen Einflusses des Betonalters wurden die Messungen 4 Tage, 28 Tage sowie 180 Tage nach Herstellung der Platten durchgeführt.
Um aus den Untersuchungen einen breiten Nutzen für die Praxis zu erzielen, basierten die eingesetzten Messverfahren auf handelsüblichen Geräten, welche jedoch bezüglich ihres Messprinzips und insbesondere der Datenerfassung und -auswertung weiterentwickelt wurden. Die Fehlstellengröße wurde bewusst klein gewählt.
Mit Ausnahme des manuellen Impakt-Echo-Verfahrens, mit welchem unter Verwendung der Originalsoftware des Herstellers keine Fehlstellen nachweisbar waren, zeigten sich alle Messverfahren geeignet, unter verschiedenen Randbedingungen Gefügestörungen zu lokalisieren. Insgesamt wurde jeder Fehlstellentyp von zumindest einem Verfahren bei mindestens zwei Versuchskörpern detektiert. Es konnten jedoch an keiner Betonplatte mit einem einzelnen Messverfahren alle vorhandenen Fehlstellen an allen Messterminen geortet werden.
Am häufigsten wurden die beiden großen oberflächennahen Fehlstellen (Hohlstelle Ø 8 cm, Kiesnest 10 cm) erkannt. Am schwersten zu lokalisieren waren die kleine Hohlstelle mit 4 cm Durchmesser sowie die beiden auf der Unterseite gelegenen Kiesnester.
Die Untersuchungen zeigen, dass für eine erfolgreiche Anwendung zerstörungsfreier Messverfahren in der Praxis die Auswahl des am besten geeigneten Verfahrens bzw. einer Kombination verschiedener Verfahren jeweils auf die vorliegende Problemstellung abgestimmt sein muss.
Für Betonbodenplatten mit hohem Feuchtegehalt (junger Beton) oder starker Bewehrung ist entweder das Ultraschall- oder das Impakt-Echo-Verfahren geeignet. Das Ultraschall-Verfahren wird von hohen Bewehrungsgehalten zwar stärker beeinflusst als das Impakt-Echo-Verfahren, besitzt aber eine bessere Auflösung und ermöglicht auch im oberflächennahen Bereich eine quantitative Bestimmung der Fehlstellentiefe. Das Impakt-Echo-Verfahren kann wegen der niederfrequenten Impulsanregung Fehlstellen erst in größeren Tiefen und mit schlechterer Auflösung nachweisen, ist aber ideal geeignet zur Bestimmung der Plattendicke aufgrund seines signifikanten Rückwandechos. Sowohl das Radar-Verfahren als auch die Impuls-Thermografie können bei hohen Feuchte- und Bewehrungsgehalten nur sehr oberflächennah eingesetzt werden.
Bei trockenem Beton und geringen bis mittleren Bewehrungsgehalten liefert das Radar-Verfahren sehr gute Ergebnisse. In kurzer Zeit ermöglicht es eine flächendeckende Ortung der Tiefenlage und Größe von Inhomogenitäten bei guter Auflösungsgenauigkeit. Vorhandene Bewehrung wird deutlich abgebildet, kann aber darunterliegende Fehlstellen verschatten. Alternativ kann die Impuls-Thermografie für die Ortung oberflächennaher Gefügestörungen eingesetzt werden. Das Verfahren eignet sich insbesondere bei Oberflächen, die nicht direkt zugänglich sind, da zwischen Infrarotkamera und Messobjekt nur Sichtkontakt bestehen muss.
Die Betongüte hatte bei keinem eingesetzten Verfahren einen erkennbaren Einfluss auf die Messergebnisse. Streng genommen ist dies jedoch nur für den Einfluss des Wasserzementwertes, der Zementart und des Zementgehalts bei gleichbleibender Sieblinie und gleicher Kornart gültig. Bei Verwendung von Leichtzuschlag sind abweichende Ergebnisse denkbar.
Fused filament fabrication (FFF) is a material extrusion-based technique often used in desktop 3D printers. Polymeric filaments are melted and are extruded through a heated nozzle to form a 3D object in layers. The extruder temperature is therefore a key parameter for a successful print job but also one of the main emission driving factors as harmful pollutants (e.g., ultrafine particles) are formed by thermal polymer degradation. The awareness of potential health risks has increased the number of emission studies in the past years. However, studies usually refer their calculated emission data to the printer set extruder temperature for comparison purposes. In this study, we used a thermocouple and an infrared camera to measure the actual extruder temperature and found significant temperature deviations to the displayed set temperature among printer models. Our result shows that printing the same filament feedstocks with three different printer models and with identical printer set temperature resulted in a variation in particle emission of around two orders of magnitude. A temperature adjustment has reduced the variation to approx. one order of magnitude. Thus, it is necessary to refer the measured emission data to the actual extruder temperature as it poses a more accurate comparison parameter for evaluation of the indoor air quality in user scenarios or for health risk assessments.