Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Active thermography (25) (entfernen)
Organisationseinheit der BAM
Impulse thermography is an active method for quantitative investigations of the near
surface region of various structures. It has recently been applied and optimized to applications in civil
engineering. For quantitative analysis of data recorded on the building site, the problems are manifold.
Here, the influence of the different surface properties on the detection and characterization of voids
and honeycombing simulated by polystyrene cubes and cubes prepared of porous concrete are
demonstrated.
Influence of concret properties on the calibration of radar, ultrasonics and active thermography
(2008)
Applications of infrared thermography in civil engineering are not limited to the identification of heat losses in building envelopes. Active infrared thermography methods enable structural investigations of building elements with one-sided access up to a depth of about 10 cm. Masonry and especially historical masonry has a very heterogeneous structure containing several different materials (brick, stone, mortar, plaster, wood, metal, etc.) with various thermal properties. As many classes of damage originate from defects that are close to the surface, active thermography is in general very well suited to assessing different test problems in cultural heritage buildings. In this paper, the physical background, equipment, environmental influences and material properties are discussed. Several application results are presented. It is shown how active thermography can be integrated into a holistic approach for the assessment of historical structures.
Impulse and lock-in thermography have been applied to detect delaminations of prototype solder joints, similar to those to be produced between Cu shunts and Cu busbar stabilisers at the Large Hadron Collider (LHC) at CERN. Two infrared cameras with different detector materials and with different spectral ranges and two excitation techniques have been tested and compared for their ability to detect delaminations behind 2 and 3 mm thick Cu shunts. We have analyzed the signal to noise ratio (SNR) for each detected defect and are able to detect defects down to a nominal edge length of 4 mm behind 2 mm thick Cu shunts by using fast impulse thermography and a camera with a microbolometer array. For the 3 mm thick Cu shunt, on the other hand, the nominal 4 mm defect is only visible in the lock-in thermography phase images and the highest SNR has been achieved with a cooled InSb-based camera. In addition, numerical simulations show the influence of the minimum detectable defect size on the shunt thickness and that the developed on-site testing technique is sufficient to find all defects that are detectable theoretically.
Ever larger high pressure die castings (HPDC) with ever thinner walls raise the issue of castings defects. Properties of components are often strongly influenced by inner porosity. In the case of high pressure die castings, shrinkage and gas porosity occur. Two possibilities of characterizing porosity – by microscopy and active thermography – are dealt with in two articles. In this article, the microscopic investigations are presented. In a second article, first the feasibility of thermographic detection will be discussed based on simulations and, thereafter, the experimental determination of porosity with active thermography will be described.