Impulse-thermography has been established as a fast and reliable tool in many areas of non-destructive testing. In recent years several investigations have been done to apply active thermography to civil engineering. For quantitative investigations in this area of application, finite difference calculations have been performed for systematic studies on the influence of environmental conditions, heating power and time, defect depth and size and thermal properties of the bulk material (concrete). The comparison of simulated and experimental data enables the quantitative analysis of defects.
Abstract
In the recent years the application of infrared thermography and especially its active approaches lock-in thermography, impulse themography and pulse phase thermography (PPT) has gained more importance for non-destructive testing (NDT). In this paper it is demonstrated that PPT is very well suited for NDT in civil engineering. The method is based on pulse heating of the investigated specimen and on the observation of the cooling down process on its surface with an infrared camera. The transient behaviour is afterwards analysed with Fast Fourier Transformation, enabling the creation of phase and amplitude images with enhanced visualisation of the defects. Results of European and National (i.e. DFG) funded projects are presented, for example the detection of voids and inhomogeneities close to the surface and the localisation of delaminations on plastered concrete and masonry specimen.
ZUSAMMENFASSUNG
Im Rahmen eines von der Deutschen Forschungsgemeinschaft geförderten Vorhabens zur zerstörungsfreien Prüfung im Bauwesen wird in der Bundesanstalt für Materialforschung und -prüfung (BAM) in Zusammenarbeit mit der Technischen Universität Berlin (TUB) die Puls-Phasen-Thermografie (PPT) weiterentwickelt, bewertet und eingesetzt. Die durch die Impuls-Thermografie (IT) aufgenommenen Daten werden mittels Fast Fourier Transformation (FFT) bearbeitet. Die durch die FFT gewonnenen Phasenbilder reduzieren die Störeinflüsse von Oberflächeninhomogenitäten und ungleichmäßiger Erwärmung.
Die dargestellten Ergebnisse zeigen deutlich, dass sich die PPT sehr gut zur zerstörungsfreien Prüfung im Bauwesen eignet. Insbesondere Inhomogenitäten im oberflächennahen Bereich, wie Ablösungen und Hohlstellen hinter Beschichtungen (Putz, CFK-Laminate etc.), aber auch Defekte in größeren Tiefen können zuverlässig geortet und bildgebend dargestellt werden.
Struktur- und Feuchteuntersuchungen von Bauteil- und Bauwerksoberflächen mit der Impuls-Thermografie
(2005)
An advanced quantitative approach of pulse-phase-thermography for nondestructive
testing in civil engineering is described in this contribution. The
characteristic frequency of the maximum phase-contrast between defects and sound
areas is used as a means for the characterization of its depth.
The new approach is tested in the laboratory on concrete structures with defects of
polystyrene. The surfaces of the structures were heated with IR-radiators for varying
time periods.
The presented investigations were funded by the Deutsche Forschungsgemeinschaft
(DFG) and were carried out in co-operation with the Technical University of Berlin
(TUB).
The active approach for non-destructive-testing in Civil Engineering (NDT-CE) with infraredthermography (IR), developed at the Federal Institute for Materials Research and Testing (BAM), is described in part one of this contribution. The active IR-approach is based on the principles of impulse- (IT) and pulse-phase-thermography (PPT). The concept is a direct result of a research project at the BAM in cooperation with the Technical University of Berlin (TUB) and was funded by the Deutsche Forschungsgemeinschaft (DFG). In the second part results of the new thermography-scanning system (thermo-scanner) of BAM on debonding of multi-layered structures, especially carbon fibre reinforced plates (CFRP) on concrete are presented. Both, the thermo-scanner developed at BAM, and the investigations carried out, are part of the
EU-Project Sustainable Bridges. In the third part of the paper the characteristic frequency of the optimum phase-contrast as a means for the characterization of defects depth in CE by means of PPT is introduced. A new quantitative approach is tested and discussed on concrete structures with defects of polystyrene and gas concrete.
False colour infrared (IR) thermography was performed on a sunny summer day in the Berlin Botanic Garden. The main interest focused on blossoms of different size, colours and shapes: disk-, bowl- and funnel-like anatomy demonstrating various modes of light absorption and heating-up during the day. Some of the flowers were phototropic or even solar tracking. Blossom temperatures ranged from 18.0 to 33.3 °C (mean 26.3 ± 2.5 °C, S.D., n = 37) at 21 °C air temperature. Several thermograms showed honey- and bumblebees also. In some cases the results are compared with those of a contact-free IR thermometry. One winter- and one late-spring-flowering plant are included in the overview.
Nach einer Einführung in die Puls-Phasen-Thermografie (PPT) wird ein neuer Ansatz für die Defekttiefenbestimmung im Frequenzraum mittels der sogenannten charakteristischen Frequenz des minimalen Phasen- und Amplitudenkontrastes zwischen Fehlstelle und ungestörtem Bereich entwickelt und anhand von systematischen Untersuchungen an Probekörpern der Bundesanstalt für Materialforschung und -prüfung und ergänzenden Simulationsrechnungen überprüft.
Die mit Rechteckimpuls-Spektral-Thermografie (RST) bezeichnete Methode, die auch als eine Rechteckimpuls-Thermografie (RIT) im Frequenzbereich oder eine durch Amplitudenauswertung ergänzte PPT für Rechteckimpulserwärmung verstanden werden kann, soll die existierenden Ansätze ergänzen und bietet eine Alternative für die Tiefenbestimmung von Defekten bei Messungen mit langen Erwärmungs- und Beobachtungszeiten, wie sie bei Anwendung von aktiver Thermografie im Bauwesen häufig vorkommen.
Thermal investigations using infrared (IR) thermometry and false colour thermography were carried out on flowering plants in the Botanical Garden of Berlin and in a private garden. Special interest went to phototropic plants that orient their blossoms towards a light source (mainly the sun) and within this group to solar trackers (heliotropism) that follow the path of the sun during the day. Best known among the latter is the sunflower. Bowl shaped flowers comparable to satellite disks focus the solar radiation effectively on their centre, resulting in a warming of the female organs at that point. Temperature differences above ambient can be as high as 10.7 K with a mean value of 6.0 K. Pollinating insects were often observed sun-basking in the bowls or on the flower disks attracted by energetic rewards in form of nectar and heat.
New thermography systems enable the application of active investigation techniques, i.e. the observation of the cooling down process after heating the surface of a structure under investigation. Defects like voids in concrete having a different thermal diffusivity in comparison to the bulk material are visualised by different surface temperatures. The differences between temperature transient curves above sound regions and above inhomogeneities are expected to include information about the defect parameters.
Experimental investigations with impulse thermography and radar on a concrete test specimen containing voids were analysed. Radar was used to determine the depth of the voids. The influence of size and depth of the voids on the temperature transient curves was studied for different heating times. The transient curves were also fitted with a simple semi-empirical model.
The applicability of pulse phase thermography (PPT) for the investigation of structures is studied systematically on concrete test specimens and on a plastered sandstone column. In the test specimens, voids and delaminations are implemented in different depths and with different sizes, modelling real voids, honeycombing and debonding. Delaminations of plaster in concrete and masonry and behind tiles on concrete are investigated. PPT is based on the frequency analysis of the cooling down process of actively heated surfaces. Therefore, it is contactless and thus completely non-destructive (if overheating of the surface is prevented), fast and allows the inspection of large surface areas. The interpretation of amplitude and phase images gives semi-quantitative information about the observed defects. The phase images provide a deeper probing up to 1015 cm in relation to the interpretation of the thermograms and to the amplitude images. In addition, the influence of surface inhomogeneities and non-uniform heating is reduced.
Impulse-thermography is an active method for quantitative investigations of the near surface region of various structures. It has recently been applied and optimised to applications in civil engineering. By using either an internal or external heat source, parts of the structure under investigation are heated up and the transient heat flux is observed by recording the temperature change at the surface as a function of time. This method is very well suited for the detection of voids and honeycombing in concrete, up to concrete covers of 10 cm as well as for the location of delaminations in multi-layered systems (e.g. plaster on concrete, CFRP-laminates on concrete, asphalt on concrete). Also safety relevant defects like voids in tendon ducts and cracks in concrete could be recognised.
Impulse thermography is an active method for quantitative investigations of the near
surface region of various structures. It has recently been applied and optimized to applications in civil
engineering. For quantitative analysis of data recorded on the building site, the problems are manifold.
Here, the influence of the different surface properties on the detection and characterization of voids
and honeycombing simulated by polystyrene cubes and cubes prepared of porous concrete are
demonstrated.
Die Kombination und direkte Datenfusion der Ergebnisse von 3DLaserscannern
zur Erfassung der Geometrie und der aktiven Thermografie zur
Ortung verdeckter Hohlstellen und anderer Inhomogenitäten liefert umfassende
quantitative Informationen über die Zuordnung von Merkmalen und Veränderungen
eines Bauteils. In diesem Beitrag werden die erforderlichen Verfahrensspezifikationen,
das Prinzip der Datenüberlagerung und ausgewählte Fallstudien aus der
Denkmalpflege vorgestellt.
Influence of concret properties on the calibration of radar, ultrasonics and active thermography
(2008)
Ziel der hier vorgestellten Untersuchungen war es, die Einflüsse von variierenden thermischen Eigenschaften des Baustoffs sowie von unterschiedlichen Emissivitäten der Oberfläche auf die Ortung von Inhomogenitäten in Bauwerksstrukturen mit der aktiven Thermografie zu quantifizieren bzw. durch geeignete Auswerteverfahren zu reduzieren. Vorgestellt werden Ergebnisse von Untersuchungen an Betonprobekörpern mit unterschiedlichen Betonrezepturen und Oberflächenbeschichtungen und -modifikationen sowie an einem historischen Mauerwerksprobekörper mit aufsteigender Feuchte. Die Auswertung der Thermografiesequenzen erfolgte sowohl im Zeit- als auch im Frequenzbereich.
In diesem Beitrag wird die Entwicklung eines aktiven Thermografieverfahrens zur zeit- und ortsaufgelösten in-situ und Echtzeit-Visualisierung von Transport- und Schädigungsprozessen für Anwendungen in Industrie und Umwelt vorgestellt. Das Verfahren ermöglicht unter Verwendung verschiedener thermischer Anregungsquellen u.a. die Bestimmung der thermischen Materialeigenschaften von Keramiken und trockenen und feuchten mineralischen Baustoffen. Schädigungsprozesse in Keramiken können in-situ visualisiert werden. Weiterhin werden Messergebnisse vorgestellt, die während des kapillaren Feuchtetransports in Naturstein erfasst wurden und diesen abbilden können.
Zerstörungsfreie Ortung von Fehlstellen und Inhomogenitäten in Bauteilen mit der Impuls-Thermografie
(2004)
Purpose – This purpose of this paper is to report about the temperature distribution in metal and ceramic powder beds during 3D printing. The differing powders are thoroughly characterized in terms of thermal conductivity, thermal diffusivity, emissivity spectra and density.
Design/methodology/approach – The temperature distribution was measured in a 3D printing appliance (Prometal R1) with the help of thin thermocouples (0.25 mm diameter) and thermographic imaging. Temperatures at the powder bed surface as well as at differing powder bed depths were determined. The thermal conductivity, thermal diffusivity and emissivity spectra of the powders were measured as well. Numerical simulation was used to verify the measured temperatures.
Findings – The ceramic powder heated up and cooled down more quickly. This finding corresponds well with numerical simulations based on measured values for thermal conductivity and thermal diffusivity as well as emissivity spectra. An observed color change at the metal powder has only little effect on emissivity in the relevant wavelength region.
Research limitations/implications – It was found that thermocouple-based temperature measurements at the powder bed surface are difficult and these results should be considered with caution.
Practical implications – The results give practitioners valuable information about the transient temperature evolution for two widely used but differing powder systems (metal, ceramic). The paramount importance of powder bed porosity for thermal conductivity was verified. Already small differences in thermal conductivity, thermal diffusivity and hence volumetric heat capacity lead to marked differences in the transient temperature evolution.
Originality/value – The paper combines several techniques such as temperature measurements, spectral emissivity measurements, measurements of thermal conductivity and diffusivity and density measurements. The obtained results are put into a numerical model to check the obtained temperature data and the other measured values for consistency. This approach illustrates that determinations of surface temperatures of the powder beds are difficult.
Anwendung der Impuls-Thermografie als quantitatives zerstörungsfreies Prüfverfahren im Bauwesen
(2002)
Zusammenfassung
Die Impuls-Thermografie ist eine aktive Methode zur Strukturuntersuchung von Bauteilen. Im Rahmen eines von der DFG geförderten Projektes wird in Kooperation mit der TU Berlin an der Bundesanstalt für Materialforschung und -prüfung zur Zeit die mögliche Anwendung der Impuls-Thermografie als zerstörungsfreies Prüfverfahren im Bauwesen untersucht.
Die Impuls-Thermografie soll zur Ortung von oberflächennahen Inhomogenitäten, bei denen es sich im Normalfall um Fehlstellen handelt, in typischen Bauteilen verwendet werden und nach Möglichkeit die Geometrie- sowie die Materialparameter der Inhomogenitäten quantitativ bestimmt werden.
Messungen werden derart durchgeführt, dass Oberflächen mit einem geeigneten Heizstrahler erwärmt, die anschließenden Abkühlungsprozesse mit einer Infrarot-Kamera betrachtet und thermische Bilddaten (Thermogramme) aufgezeichnet werden. Der Hauptansatzpunkt für die quantitative Auswertung der Messdaten ist die Betrachtung von Temperatur-Zeit-Kurven (Transienten) des Abkühlungsprozesses über fehlerfreien und fehlerhaften Bereichen des Probekörpers. Zusätzlich werden auf Basis der Finiten-Differenzen-Methode numerische Simulationen durchgeführt. Quantitative Ergebnisse werden sowohl durch den Vergleich der experimentellen Daten mit den Simulationsrechnungen als auch durch eine Anpassung analytischer Funktionen an die Transienten erzielt.
Active infrared thermography in civil engineering - quantitative analysis by numerical simulation
(2003)
The cooling-down process of building structures after heating-up with an external radiation source was analysed to detect voids inside and below the surface. Quantitative results of concrete test specimen containing voids with different sizes at various depths will be presented here. The experimental results were compared to numerical simulations performed with a Finite Difference program developed at BAM.
Ortung von Hohlstellen und Ablösungen in Betonkonstruktionen mit Radar und Impuls-Thermografie
(2003)
Impulse-thermography is an active method for quantitative investigation of the near surface region of various structures which has recently been applied to civil engineering. It is well suited for the detection of voids and honeycombing in concrete up to concrete covers of 10 cm and more. For quantitative analysis, a computer program for numerical simulation of the heating up and cooling down processes was developed based on Finite Differences. With this program parameter studies have been performed for investigating the influence of environmental conditions, material parameters and geometry on the thermal behaviour. The comparison between experimental and simulated results enables the Inverse Solution.
Applications of infrared thermography in civil engineering are not limited to the identification of heat losses in building envelopes. Active infrared thermography methods enable structural investigations of building elements with one-sided access up to a depth of about 10 cm. Masonry and especially historical masonry has a very heterogeneous structure containing several different materials (brick, stone, mortar, plaster, wood, metal, etc.) with various thermal properties. As many classes of damage originate from defects that are close to the surface, active thermography is in general very well suited to assessing different test problems in cultural heritage buildings. In this paper, the physical background, equipment, environmental influences and material properties are discussed. Several application results are presented. It is shown how active thermography can be integrated into a holistic approach for the assessment of historical structures.
Fallbeispiele für die Anwendung der 3D-Messtechnik und der aktiven Thermografie in der Denkmalpflege
(2010)
The paper presents some of the results obtained within a project concerning the validation of the thermographic inspection method applied to rotor blades of wind turbines. Thermographic testing (TT) is a well established nondestructive testing method under laboratory conditions. It is suited to detect typical structural features and also faults and damages within the blade structure. However, the onsite application for wind turbines during Operation is not straightforward. Some resuits of non-rotating blades as well as of rotating blades are presented. The simultaneous recording of all blades in the rotating state allows the application of a reference method suppressing disturbing influences and leading to enhanced thermal contrasts.
Impulse and lock-in thermography have been applied to detect delaminations of prototype solder joints, similar to those to be produced between Cu shunts and Cu busbar stabilisers at the Large Hadron Collider (LHC) at CERN. Two infrared cameras with different detector materials and with different spectral ranges and two excitation techniques have been tested and compared for their ability to detect delaminations behind 2 and 3 mm thick Cu shunts. We have analyzed the signal to noise ratio (SNR) for each detected defect and are able to detect defects down to a nominal edge length of 4 mm behind 2 mm thick Cu shunts by using fast impulse thermography and a camera with a microbolometer array. For the 3 mm thick Cu shunt, on the other hand, the nominal 4 mm defect is only visible in the lock-in thermography phase images and the highest SNR has been achieved with a cooled InSb-based camera. In addition, numerical simulations show the influence of the minimum detectable defect size on the shunt thickness and that the developed on-site testing technique is sufficient to find all defects that are detectable theoretically.
Pulse thermography is a non-destructive testing method based on infrared imaging of transient thermal patterns. Heating the surface of the structure under test for a short period of time generates a non-stationary temperature distribution and thus a thermal contrast between the defect and the sound material. In modern NDT, a quantitative characterization of hidden imperfections in materials is desired. In particular, defect depth and shape are of interest. The reconstruction of the defect from thermography data is a nonlinear inverse problem, and ill-posed. We propose an algorithm for the identification of subsurface defects based on the travel time of the reflected thermal pulse. Our work extends results by Lugin and Netzelmann, taking lateral thermal flows directly into account while retrieving the defect depth. This requires significantly less computational work. Quantitative information about the defect shape and depth is obtained. Application of our method to both thermography data generated by a finite element simulation and experimental heating of PVC test specimens with different defects yields good reconstruction of the actual defects.
Für die optische Erwärmung von Prüfteiloberflächen sind Blitz- und Halogenlampen Stand der Technik. Der Vorteil dieser Wärmequellen liegt in ihren relativ geringen Anschaffungskosten bei gleichzeitig hohen Leistungsdichten am Prüfobjekt. Nachteilig ist bei den Halogenlampen die Limitierung der möglichen Modulationsffequenz auf ca. 1 Hz für die Anwendung dieser Quelle in der Lockin-Thermografie. Blitzlampen bieten für gewöhnlich nur eine feste Blitzdauer bei einer geringen Taktrate. Beide Anregungsquellen müssen in Reflexionsanordnung mit Filtern betrieben werden um die entstehende thermische Eigenstrahlung als Störquelle zu eliminieren. Wir stellen Untersuchungen an Hochleistungs-LEDs für den Einsatz in der aktiven Thermografie vor. Diese Lichtquellen werden durch die rasante Entwicklung der möglichen Leistungsdichten nun auch für die thermografische ZfP interessant. Sie zeigen ähnlich dem Laser eine schmale und auf den Werkstoff abstimmbare spektrale Verteilung der Strahlungsleistung bei moderaten Kosten. Die zugrunde liegende Elektrolumineszenz generiert kaum Wärmestrahlung und ermöglicht dadurch die Prüfung während des Erwärmungsvorganges ohne größeren Aufwand. Modulationsfrequenzen über 100 Hz mit thermischen Eindringtiefen < 1 mm sind möglich. Dadurch qualifizieren sich die LEDs zur Anwendung in der Lockin-Thermografie von Metallen und zur oberflächennahen Prüfung von Schichtsystemen. Durch die fast verzögerungsffeie Reaktion der LED auf das steuernde Signal sind nahezu beliebige zeitliche Anregungsformen möglich. Mit solch flexiblen Anregungsformen ließen sich bereits bei den photothermischen Verfahren erfolgreich höhere Tiefenreichweiten und -auflösungen gegenüber den klassischen Methoden der monofrequenten Lockin - und energiereichen Kurzimpuls-Anregung erzielen. Untersuchungen dieser Möglichkeiten im praktischen Einsatz der HochleistungsLEDs werden vorgestellt und mit herkömmlichen Lichtquellen verglichen.
Die messtechnische Erfassung von Bauwerkschäden ist eine wichtige Voraussetzung für die dreidimensionale und zeitaufgelöste Darstellung von möglicherweise sicherheitsrelevanten Veränderungen an Bauwerken, wie z. B. Verformungen, Verwindungen und Risswachstum. Ziel des vorgestellten Projektes war die Entwicklung eines Verfahrens zur effizienten und wiederholbaren 3D-Schadenkartierung an zum Teil empfindlichen Bauteiloberflächen.
Ever larger high pressure die castings (HPDC) with ever thinner walls raise the issue of castings defects. Properties of components are often strongly influenced by inner porosity. In the case of high pressure die castings, shrinkage and gas porosity occur. Two possibilities of characterizing porosity – by microscopy and active thermography – are dealt with in two articles. In this article, the microscopic investigations are presented. In a second article, first the feasibility of thermographic detection will be discussed based on simulations and, thereafter, the experimental determination of porosity with active thermography will be described.
Ever larger high pressure die castings (HPDC) with ever thinner walls raise the issue of casting defects. Properties of components are often strongly influenced by inner porosity. In the case of high pressure die castings, shrinkage and gas porosity occur. Two possibilities of characterizing porosity - by microscopy and acitve thermography - are dealt with in two articles. In the previous article, the microscopic investigations are presented. In this article, first the feasibility of thermographic detection will be discussed based on simulations and, thereafter, the experimental determination of porosity with active thermography will be described.
We present a first direct measurement of the temperature during milling combined with in situ Raman spectroscopy monitoring. The data reveal a low temperature increase due to the mechanical impact and clear temperature increases as a consequence of the reaction heat. Based on the data, temperature rises as postulated in the magma plasma and hot spot theory can be excluded for soft matter milling syntheses.
In diesem Beitrag werden zerstörungsfreie Untersuchungen mittels aktiver Thermografie an Probekörpern aus CFK und GFK mit unterschiedlichen künstlichen Fehlstellen vorgestellt. Dabei wird die zeitliche und örtliche Temperaturverteilung nach der Erwärmung mit Blitzlampen oder mit einem Infrarot-Strahler mit einer Infrarot-Kamera erfasst. Zur späteren Rekonstruktion der Messdaten wurde ein numerisches Modell entwickelt. Dazu war die Bestimmung der thermophysikalischen und optischen Materialeigenschaften erforderlich, was in diesem Beitrag ebenfalls beschrieben wird. Die Ergebnisse der numerischen Modellierung werden mit den experimentellen Untersuchungen der aktiven Thermografie verglichen. Weiterhin werden die experimentellen Untersuchungen hinsichtlich der beiden Materialsysteme CFK und GFK und unter Berücksichtigung der Teiltransparenz des GFK-Materials sowie der unterschiedlichen Anregungsquellen bewertet.
For assuring the safety and reliability of components and constructions in energy applications made of fiber-reinforced polymers (e.g., blades of wind turbines and tidal power plants, engine chassis, flexible oil and gas pipelines) innovative non-destructive testing methods are required. Within the European Project VITCEA complementary methods (shearography, microwave, ultrasonics and thermography) have been further developed and validated. Together with partners from the industry, test specimens have been constructed and selected on-site containing different artificial and natural defect artefacts. As base materials, carbon and glass fibers in different orientations and layering embedded in different matrix materials (epoxy, polyamide) have been considered. In this contribution, the validation of flash and lock-in thermography to these testing problems is presented. Data analysis is based on thermal contrasts and phase evaluation techniques. Experimental data are compared to analytical and numerical models. Among others, the influence of two different types of artificial defects (flat bottom holes and delaminations) with varying diameters and depths and of two different materials (CFRP and GFRP) with unidirectional and quasi-isotropic fiber alignment is discussed.
We present an in situ triple coupling of synchrotron X-ray diffraction with Raman spectroscopy, and thermography to study milling reactions in real time. This combination of methods allows a correlation of the structural evolution with temperature information. The temperature information is crucial for understanding both the thermodynamics and reaction kinetics. The reaction mechanisms of three prototypical mechanochemical syntheses, a cocrystal formation, a C@C bond formation (Knoevenagel condensation), and the formation
of a manganese-phosphonate, were elucidated. Trends in the temperature development during milling are identified. The heat of reaction and latent heat of crystallization of the product contribute to the overall temperature increase. A decrease in temperature occurs via release of, for example, water as a byproduct.
Solid and liquid intermediates are detected. The influence of the mechanical impact could be separated from temperature effects caused by the reaction.
Der Umfang der durch Impacts in Faserverbundmaterialien erzeugten Schäden ist abhängig von der Energie des Impacts, von der Zusammensetzung und dem Aufbau der Faserverbundwerkstoffe und von der Geometrie der Bauteile und hier im Wesentlichen von der Dicke des Bauteils. Der zerstörungsfreie Nachweis dieser Schädigungen kann sowohl mit Ultraschallverfahren als auch mit Verfahren der aktiven Thermografie erfolgen. Ein Vergleich der Nachweisempfindlichkeiten dieser Verfahren für die unterschiedlichen Schädigungen wird in diesem Beitrag in Abhängigkeit vom verwendeten Faserverbundwerkstoff (CFK und GFK), der Dicke des Materials und von der Impactenergie durchgeführt. Ergänzt werden die im Anschluss an die Schädigung eingesetzten ZfP-Verfahren mit zeitlich hochaufgelösten Thermografiemessungen, die bereits während des Impacts aufgenommen wurden.
Carbon fiber reinforced polymer (CFRP) specimens with artificial delaminations and with impact damage have been characterized using active thermography with flash excitation. Systematic investigations have been performed in four different experimental configurations of flash lamps and infrared (IR) camera in transmission as well as in reflection alignment. It is shown here that the diffusivities determined for the sound and for the damaged areas give a good measure for damage characterization. Although reflection measurements also give information about defect depth, reflection measurements from only one side are not sufficient for assessing the whole cross section of the specimens. Thus, depending on sample thickness the lateral size of damage could only be determined from reflections measurements from both sides or from transmission measurements. In this paper, measurement accuracy and limits of flash thermography for the investigation of CFRP specimens are presented in detail together with quantitative data concerning the defects.
Eine Arbeitsgruppe der BAM in der Abteilung für Zerstörungsfreie Prüfung forscht seit 2011 an verschiedenen technischen Fragestellungen, die sich aus dem thermografischen Lösungsansatz ergeben. Zum Beispiel werden spezielle Prüfkörper aus GFK im Labor unter dem Gesichtspunkt untersucht, inwieweit (materielle) innere Strukturen und äußerlich nicht sichtbare Schäden mit Thermografie offenbart werden können. Hierbei werden verschiedene Anregungs- und Auswertungstechniken auf ihre Eignung für diese Problemstellung untersucht. Der folgende Beitrag erläutert einige technische Schwierigkeiten bei der praktischen Anwendung der geplanten Inspektionsmethode und stellt einen erfolgversprechenden Lösungsansatz vor.
Impact damages and delaminations in fibre-reinforced composites (FRC) might not be visible at the surface, but could have an influence on the resistance and on the long-term behaviour of the component. Therefore, and especially for safety relevant structures, non-destructive methods are required for the assessment of such damages.
Active thermography methods are suitable to characterize damages after loading using different kind of excitation techniques and various configurations of infrared (IR) camera and heating sources. Here, flash lamps, impulse excitation with infrared radiator and lock-in technique with halogen lamps or widened laser beams are suited. In addition, non-optical sources like sonotrodes (requiring direct contact to the structure) or induction generators (only suited for carbon fibre reinforced polymer (CFRP) structures) could be applied as well. For the investigation of the evolution of the damage during the impact, passive thermography can be applied in-situ. Elastic and plastic deformations alter the temperature of the structure and thus the temperature on the surface.
In this contribution, at first the general principles of quantitative defect characterisation in FRC using active thermography with flash, impulse and lock-in excitation are described. Optical and thermal properties of the FRC material and its anisotropy are considered. Results of phase differences obtained at flat bottom holes with flash and lock-in thermography are compared for qualifying both methods for quantitative defect characterization. Secondly, the damage evolution of CFRP and GFRP structures under impact load and static tensile loading is described. The spatial and temporal evolution of the surface temperature enables us to distinguish matrix cracks or fibre-matrix separation from delaminations between the layers. Afterwards, all results for loading defects, obtained by passive and active thermography, are compared with each other. Fig. 1 and 2 show the difference of passive and flash thermography obtained at impact and tensile loaded CFRP plates, respectively. As one purpose of these investigations is the development of standards within national (DIN) and European (CEN) standardisation bodies, new draft and final standards are presented and further needs are discussed at the end of the presentation.
Lockin thermography as well as flash thermography are very well suited for non-destructive testing and characterisation of inhomogeneities and damage in CFRP structures. Both methods are applied more and more in research and industry, but until know it is not clear which are the advantages of one method against the other. In
this paper, results of two research projects concerning the validation and standardisation of both methods are presented. Three different types of CFRP test specimens consisting of well-defined flat bottom holes, of artificial delaminations made of PTFE plates embedded in CFRP and of real impact damage have been investigated systematically with flash and lockin excitation. Here, the phase images of both methods are compared qualitatively as well as quantitatively.
Active thermography is an efficient non-destructive testing method for investigating the internal structure of larger carbon fiber reinforced plastic (CFRP) components as well as smaller CFRP components in mass customization. The method can be applied contactless and automated. This study contains systematic investigations of CFRP structures with typical defects and inhomogeneities occurring during production by means of flash thermography in reflection and transmission configuration and by computed tomography (CT). The latter one was used as a reference method, since also very small defects at larger depth can be visualized with high spatial resolution. The CFRP structures consist of plates which contain metallic and non-metallic inclusions, contaminations with glue or wax rests, areas with inhomogeneous re-injection of dry parts, fiber misalignments, and fiber damages. Further on, two specimens have been glued together with different artificial inhomogeneities of the four glue beads. The results of the applied methods are compared and the advantages and disadvantages of each configuration are discussed based on the detectability of the inhomogeneities. It is shown that although CT has led to best contrasts and spatial resolutions in displaying the inhomogeneities and inclusions, flash thermography is very well suited to detect most of these structures. Considering that flash thermography can be applied on-site and has a high potential for automation and for a fast and efficient testing, it can be highly recommended for quality assurance during and after production of CFRP structures.
Standards for the application of flash thermography as well as of lock-in thermography are urgently required.
Both methods are applied more and more often in research and industry, but still extensive validation procedures are required for each individual application. In this paper, the results of two research projects concerning the validation and standardisation of both methods are presented. This includes results of a detailed study of the influence of measurements parameters on flash thermography, of the comparison of the lateral resolution obtained with flash and lock-in thermography and the description of a draft standard for flash thermography.
Weltweit errichtet man zunehmend Offshore-Windkraftanlagen (WKA). Diese auf hoher See errichteten WKA benötigen geeignete Wartungs- und Instandhaltungskonzepte. Bestehende Konzepte aus dem Landbereich geraten unter Offshore-Bedingungen an ihre Grenzen oder lassen sich überhaupt nicht anwenden, daher müssen neue Ansätze erprobt werden. Im Rahmen des BMBF geförderten Forschungsprojektes "IKARUS" ist das Potential der (berührungslosen) thermografischen Fernerkundung zur Zustandsüberwachung der Rotorblätter von WKA zu untersuchen.
Veränderungen der Umgebungsbedingungen wie z.B. solare Einstrahlung oder der Tagestemperaturgang führen zu veränderlichen Energieeinträgen in ein Objekt, die beim Vorhandensein von Inhomogenitäten im Material oder Strukturmerkmalen thermische Signaturen hervorrufen können. Ebenso können Veränderungen der Witterungsbedingungen dazu führen, dass bereits vorhandene thermische Signaturen wieder ausgelöscht werden. Daher ist es unbedingt notwendig, systematische Langzeitmessungen bei verschiedenen Umgebungsbedingungen durchzuführen, um Fehlinterpretationen zu vermeiden.
In diesem Beitrag wird anhand von Laborversuchen und Simulationen zunächst die grundsätzliche Eignung des thermografischen Ansatzes für glasfaserverstärkte Kunststoffe (GFK), aus denen die Außenhüllen der Rotorblätter gefertigt sind, demonstriert. Hierbei werden unterschiedliche Arten von Defekten an GFK vorgestellt, die zu thermischen Signaturen an Rotorblättern führen können. Anschließend werden Zwischenergebnisse aus einem laufenden Langzeitversuch zu einem demontierten Rotorblattsegment vorgestellt, welches unter verschiedenen Witterungsbedingungen und zu verschiedenen Tages- und Jahreszeiten thermografisch beobachtet wurde.
Im Rahmen des INS-Projekts „Durchführung von Ringversuchen zur Normung und Standardisierung der aktiven Thermografie mit Blitzlichtanregung“ wurden Ringversuche durchgeführt, die die Zuverlässigkeit, Vergleichbarkeit und Effektivität der Blitzthermografie für unterschiedliche Prüfprobleme nachweisen sollten. Weiterhin sollten diese Untersuchungen als Methodenvalidierungsstudie die Richtigkeit und Präzision der Blitzthermografie nachweisen und Vergleichsinformationen unterschiedlicher Geräteausstattungen liefern. Im Normausschuss NA 062-08-27 AA „Visuelle und thermografische Prüfung“ des DIN werden die Ergebnisse die Erarbeitung eines Normentwurfs zur Blitzthermografie unterstützen. In diesem Beitrag werden die Ringversuche beschrieben und ausgewählte Ergebnisse präsentiert.
This study evaluates whether subsurface features in rotor blades, mainly made of Glass Fibre Reinforced Plastics (GFRP), can generally be detected with ‘‘solar thermography”. First, the suitability of the sun is tested for acting as a heat source for applying active thermography on a 30 mm thick GFRP test specimen. Second, a defective rotor blade segment is inspected outdoors under ideal natural conditions using the sun as excitation source. Additionally, numerical FEM-simulations are performed and the comparability between experiment and simulation is evaluated for outdoor measurements.
Methods for the combination (i. e. comparison and overlay) and data fusion (i. e. integration of all data in one data set, replacement of data) of active thermography and D laser scanner (light section method) have been developed. Systematic investigations for quantification of damage in historic structures are presented using both techniques. A case study shows that reproducible investigations at regular time intervals are very well suited for structural monitoring.
In diesem Beitrag werden die Möglichkeiten der Ortung von Fehlstellen in Cu Lötverbindungen unterhalb verschiedener Cu Blechdicken mit aktiver Thermografie demonstriert. Dabei wurden die Anregung mit Blitzlicht und die periodische Anregung mit der Lock-In Technik miteinander verglichen. Die Vor- und Nachteile der Anwendung unterschiedlicher IR-Kamerasysteme, einer gekühlten InSb-Quantendetektor IR-Kamera und einer Mikrobolometer IR-Kamera, werden dargestellt. Als objektives Kriterium wurde das SNR für unterschiedliche Fehlstellengrößen herangezogen.
As shown recently, the quantification of damage in historic masonry structures is possible by using active thermography. In this paper, a case study is presented concerning systematic studies of the determination of damage size and prognosis of damage increase inside a sandstone column by using different approaches of active thermography. Various heating sources as well as impulse and periodic heating have been compared. Reproducible investigations in regular time intervals for structural monitoring are possible.
Active thermography is sensitive to inhomogeneities at and below the surface of objects investigated. Thus, it should be useful for detecting plaster delaminations on concrete. In this paper, the results of field and laboratory investigations into plaster-covered concrete were compared. For evaluating the bonding state of the plaster it is not sufficient to study only the thermal contrasts at the surface of the investigated objects. The experimental results suggest that the overall thermal behaviour has to be considered.
Anwendungsbreiche und Grenzen der Blitzthermografie - Entwicklung eines anwendungsnahen Standards
(2012)
Comparison of quantitative defect characterization using pulse-phase and lock-in thermography
(2016)
Using optical excitation sources for active thermography enables a contactless, remote, and non-destructive testing of materials and structures. Currently, two kinds of temporal excitation techniques have been established: pulse or flash excitation, usingmostly flash lamps; and periodic or lock-in excitation, using halogen lamps, LED, or laser arrays. From the experimental point of view, both techniques have their advantages and disadvantages. Concerning the comparison of the testing results of both techniques, only very few studies have been performed in the past. In this contribution, the phase values obtained at flat bottom holes in steel and CFRP and the spatial resolution measured at crossed notches in steel using flash and lock-in excitation are compared quantitatively.
Mit aktiver Thermografie können in Mauerwerksstrukturen sowohl die Oberflächeneigenschaften als auch Inhomogenitäten bis in eine Tiefe von mehreren Zentimetern zerstörungsfrei untersucht werden. Neben der Charakterisierung struktureller Eigenschaften wie Risse, Ablösungen und Aufbau des Mauerwerks sind auch Aussagen zu den thermischen Materialeigenschaften und der Feuchte möglich. In diesem Beitrag werden das Prinzip des Messverfahrens, Laboruntersuchungen und eine Fallstudie vorgestellt.
Pulse thermography of concrete structures is used in civil engineering for detecting voids, honeycombing and delamination. Quantitatively realistic numerical 3D simulation is difficult due to the arising boundary layer at the heated surface and unreliable information about material parameters and environmental conditions. We address both issues by a semi-analytic reformulation of the heat transport problem and by parameter identification. Numerical results are compared with measurements of a test specimen.
Sowohl in der Denkmalpflege als auch in anderen Anwendungsbereichen der zerstörungsfreien Prüfung können größere kostenintensive Erhaltungs- und Instandsetzungsmaßnahmen durch das frühzeitige Erkennen und Einschätzen von Schäden vermieden werden. Eine derartige vorbeugende Instandsetzung ist jedoch nur möglich, wenn häufige Inspektionen kostengünstig und schnell durchgeführt werden können. Systematische Methoden zur Beobachtung und Erfassung von Prozessen über einen längeren Zeitraum sowie deren Überwachung werden unter dem Begriff "Monitoring" zusammengefasst.
Das Ziel des Forschungsvorhabens „Zerstörungsfreie Ortung von Gefügestörungen in Betonbodenplatten“ bestand in der Entwicklung eines Untersuchungskonzepts zur sicheren Ortung und Erfassung von Gefügestörungen in einseitig zugänglichen Betonplatten durch den kombinierten Einsatz verschiedener zerstörungsfreier Prüfverfahren. Hierfür wurde die Leistungsfähigkeit der folgenden Messverfahren hinsichtlich ihrer Aussageschärfe, Anwendungsgrenzen und Messgeschwindigkeit bei praxisnahen Randbedingungen untersucht:
- Impakt-Echo, manuelle Impaktauslösung
- Impakt-Echo, automatisierte Impaktauslösung
- Ultraschall-Echo mit multistatischem Array
- Impuls-Thermografie
- Radar
Als Versuchskörper dienten sechs liegend hergestellte Betonplatten der Abmessungen 200/200/30 cm aus zwei verschiedenen Betongüten und mit unterschiedlichem Bewehrungsgehalt (Bewehrungsgrade 0 %, 0 ,9 %, 2 ,6 %), von denen vier Platten auf trockenem und zwei Platten auf ständig nass gehaltenem Sand gelagert waren. Alle sechs Platten enthielten jeweils dieselben künstlich eingebrachten Fehlstellen: vier quadratische Kiesnester in unterschiedlicher Tiefe mit Kantenlängen zwischen 10 und 15 cm sowie drei oberflächennahe Hohlstellen (Ø 4/6/8 cm). Zur Erfassung eines möglichen Einflusses des Betonalters wurden die Messungen 4 Tage, 28 Tage sowie 180 Tage nach Herstellung der Platten durchgeführt.
Um aus den Untersuchungen einen breiten Nutzen für die Praxis zu erzielen, basierten die eingesetzten Messverfahren auf handelsüblichen Geräten, welche jedoch bezüglich ihres Messprinzips und insbesondere der Datenerfassung und -auswertung weiterentwickelt wurden. Die Fehlstellengröße wurde bewusst klein gewählt.
Mit Ausnahme des manuellen Impakt-Echo-Verfahrens, mit welchem unter Verwendung der Originalsoftware des Herstellers keine Fehlstellen nachweisbar waren, zeigten sich alle Messverfahren geeignet, unter verschiedenen Randbedingungen Gefügestörungen zu lokalisieren. Insgesamt wurde jeder Fehlstellentyp von zumindest einem Verfahren bei mindestens zwei Versuchskörpern detektiert. Es konnten jedoch an keiner Betonplatte mit einem einzelnen Messverfahren alle vorhandenen Fehlstellen an allen Messterminen geortet werden.
Am häufigsten wurden die beiden großen oberflächennahen Fehlstellen (Hohlstelle Ø 8 cm, Kiesnest 10 cm) erkannt. Am schwersten zu lokalisieren waren die kleine Hohlstelle mit 4 cm Durchmesser sowie die beiden auf der Unterseite gelegenen Kiesnester.
Die Untersuchungen zeigen, dass für eine erfolgreiche Anwendung zerstörungsfreier Messverfahren in der Praxis die Auswahl des am besten geeigneten Verfahrens bzw. einer Kombination verschiedener Verfahren jeweils auf die vorliegende Problemstellung abgestimmt sein muss.
Für Betonbodenplatten mit hohem Feuchtegehalt (junger Beton) oder starker Bewehrung ist entweder das Ultraschall- oder das Impakt-Echo-Verfahren geeignet. Das Ultraschall-Verfahren wird von hohen Bewehrungsgehalten zwar stärker beeinflusst als das Impakt-Echo-Verfahren, besitzt aber eine bessere Auflösung und ermöglicht auch im oberflächennahen Bereich eine quantitative Bestimmung der Fehlstellentiefe. Das Impakt-Echo-Verfahren kann wegen der niederfrequenten Impulsanregung Fehlstellen erst in größeren Tiefen und mit schlechterer Auflösung nachweisen, ist aber ideal geeignet zur Bestimmung der Plattendicke aufgrund seines signifikanten Rückwandechos. Sowohl das Radar-Verfahren als auch die Impuls-Thermografie können bei hohen Feuchte- und Bewehrungsgehalten nur sehr oberflächennah eingesetzt werden.
Bei trockenem Beton und geringen bis mittleren Bewehrungsgehalten liefert das Radar-Verfahren sehr gute Ergebnisse. In kurzer Zeit ermöglicht es eine flächendeckende Ortung der Tiefenlage und Größe von Inhomogenitäten bei guter Auflösungsgenauigkeit. Vorhandene Bewehrung wird deutlich abgebildet, kann aber darunterliegende Fehlstellen verschatten. Alternativ kann die Impuls-Thermografie für die Ortung oberflächennaher Gefügestörungen eingesetzt werden. Das Verfahren eignet sich insbesondere bei Oberflächen, die nicht direkt zugänglich sind, da zwischen Infrarotkamera und Messobjekt nur Sichtkontakt bestehen muss.
Die Betongüte hatte bei keinem eingesetzten Verfahren einen erkennbaren Einfluss auf die Messergebnisse. Streng genommen ist dies jedoch nur für den Einfluss des Wasserzementwertes, der Zementart und des Zementgehalts bei gleichbleibender Sieblinie und gleicher Kornart gültig. Bei Verwendung von Leichtzuschlag sind abweichende Ergebnisse denkbar.
The increased use of fibre reinforced plastic (FRP) composites for improved efficiency and reliability in energy related applications, e.g. wind and marine turbine blades, nacelles, oil and gas flexible risers, also increases the demand for innovative non-destructive testing technologies. In this contribution, results concerning the characterisation of CFRP and GFRP during and after quasi-static tensile loading are presented. It includes the measurement of optical properties in the infrared spectral range, tensile loading tests with the observation of the temperature distribution at one or both sides of the specimens using an infrared camera for the preparation and monitoring of intended natural defects, and active thermography inspections after tensile loading. It is shown that the defect preparation was successful. Thermographic monitoring during and active thermography testing after tensile loading enable the detection of the lateral extend of the generated defects. Differences between CFRP and GFRP materials are discussed.
In diesem Beitrag werden zerstörungsfreie Untersuchungen mittels aktiver Thermografie an Probekörpern aus CFK und GFK mit unterschiedlichen künstlichen Fehlstellen vorgestellt. Dabei wird die zeitliche und örtliche Temperaturverteilung nach Erwärmung mit Blitzlampen oder mit einem Infrarot-Strahler mit einer Infrarot-Kamera erfasst. Zur Rekonstruktion der Messdaten wurde ein numerisches Modell entwickelt. Dazu war die Bestimmung der thermischen und optischen Materialeigenschaften erforderlich.
Im EMRP-Projekt VITCEA werden komplementäre ZFP-Verfahren zur Prüfung von Faserverbundwerkstoffen weiterentwickelt und validiert. In diesem Beitrag werden Ergebnisse verschiedener Techniken der aktiven Thermografie und des Ultraschalls vorgestellt. Die Nachweisempfindlichkeiten bezüglich künstlicher und natürlicher Fehler mit unterschiedlichen lateralen Ausdehnungen und in verschiedenen Tiefen werden miteinander verglichen.
Die Bewertung des Zustandes und der Haftung von Putz und Fassadenelementen auf den darunterliegenden Bauwerksstrukturen ist eine häufig auftretende Fragestellung bei der Erhaltung und Instandsetzung von Bauwerken und Baudenkmälern. Hier müssen nicht nur wirtschaftliche und denkmalpflegerische, sondern auch sicherheitsrelevante Aspekte berücksichtigt werden. Fehlstellen und Ablösungen können, auch wiederholend, mit hoher Nachweisempfindlichkeit mit aktiven Thermografieverfahren geortet und unter bestimmten Voraussetzungen quantitativ bewertet werden. Dazu wird der zu untersuchende Bereich zunächst kurzzeitig (mehrere Minuten lang) erwärmt und anschließend die Abkühlung mit einer Infrarotkamera aufgezeichnet. Systematische Untersuchungen an Probekörpern mit einer Vielzahl unterschiedlicher Fehlstellen unterhalb von Kalkputz, Fliesen und Klinkerriemchen zeigen, dass die Fehlstellen sowohl mittels künstlicher Erwärmung durch einen Infrarotstrahler als auch mittels natürlicher Erwärmung durch die Sonne detektiert und charakterisiert werden können. ---------------------------------------------------------------------------------------------------------------------------------------
The evaluation of condition and adhesion of plaster and façade elements to the underlying building structure is a common issue in the maintenance and repair of buildings and monuments. Here not only economic and preservation, but also safety relevant aspects have to be considered. Voids and delaminations can be detected repeatedly with high sensitivity using active thermography methods. Under certain conditions, also a quantitative evaluation is possible. The area under investigation has to be heated up for a short time (up to several minutes). Subsequently, the cooling down is recorded using an infrared camera. Systematic studies on test specimens with a variety of defects below lime plaster, tiles and brick tiles show that the defects can be detected and even characterized both by means of artificial heating using an infrared heater, as well as by natural solar heating.
Aktive Thermografieverfahren werden immer häufiger zur zerstörungsfreien Prüfung von Faserverbundwerkstoffen eingesetzt, da diese völlig berührungslos arbeiten und sowohl zur Prüfung großflächiger Strukturen als auch von großen Stückzahlen kleinerer Komponenten in der Fertigung eingesetzt werden können. Dieser Beitrag beschäftigt sich mit Untersuchungen an typischen Defekten und Inhomogenitäten, die bereits während der Fertigung von CFK Bauteilen entstehen oder unbeabsichtigt mit eingebaut werden. Systematische Untersuchungen wurden mit Blitzthermografie in Reflexions- und Transmissionskonfiguration und mit Computertomographie (CT) durchgeführt. Die CT wurde dabei als Referenzverfahren genutzt, da dieses Verfahren auch kleinere Defekte mit relativ hoher Ortsauflösung und unabhängig von der Tiefe darstellen kann.
Im Beitrag werden Verfahren und Strategien basierend auf optischen und thermografischen Methoden zur Lokalisierung, Erfassung und Bewertung von Putzablösungen und Ablösungen von Fassadenelementen vorgestellt. Abgelöste Fassadenbereiche zeigen dabei sowohl geometrische als auch thermische Auffälligkeiten, die im Rahmen eines Monitoring auch über größere Zeiträume verfolgt werden können. Als optische Verfahren werden die Stereophotogrammetrie und die trackingbasierte taktile 3D-Erfassung von Oberflächenmerkmalen eingesetzt. Zur Charakterisierung verdeckter Ablösungen und Bauteile wird die aktive Thermografie mit natürlicher und künstlicher Erwärmung der Bauteiloberfläche verwendet. Systematische Untersuchungen an Probekörpern und Fallstudien (Magdeburger Dom, Wandbild in Cobbelsdorf) zeigen, wie u. a. mit der Verfahrenskombination Ablösungen und Materialinhomogenitäten unterschieden werden können.
Lockin thermography is a well-suited method for the characterization of structures made of both metal and fiber reinforced plastic. In most cases, only phase images are analyzed, although the amplitude images might contain useful information as well. Thus, systematic studies of lockin thermography are presented, assessing amplitude and phase images for the detection and quantification of defects in isotropic (steel) and anisotropic (carbon fiber reinforced plastic) materials. Characterized defects are flat bottom holes with different diameters and various remaining wall thicknesses as well as crossed notches at different depths. The excitation frequency was varied while keeping the number of analyzed excitation periods nearly constant for each material. The data analysis was focused on the detectability of the defects both in the amplitude and phase images, including the determination of the signal-to-noise ratio and of the spatial resolution. As a result, the limits of defect detectability and spatial resolution are given for each material
Active thermography is well suited for the detection of delaminations and cracks in façade elements like plaster and tiles. Not only artificial heating but also solar heating can be used if the adjustment of the façade and the weather conditions are suitable. Optical methods like laser scanners, photogrammetric methods and crack tracking sensors are providing geometrical 3D data which can be used for a 3D mapping of thermograms and for providing data with higher geometrical resolution. Thus, by the combination and fusion of these data, a comprehensive mapping and monitoring of damages of façade systems is possible.