Energy dispersive and wavelength dispersive X-ray spectrometry are used to determine the composition of a specimen in a scanning electron microscope (SEM) by electron probe microanalysis (EPMA). A valuable completion for the SEM is analysis by X-ray fluorescence (XRFA). The main advantage of this method consists in its low detection limit. XRFA with a SEM uses the same spectrometers as for EPMA, necessary are only an additional X-ray source for the excitation of fluorescence spectra and software for their evaluation. Recent developments of smart low-power X-ray tubes and X-ray optical components enabled the construction of compact X-ray sources with focussing properties as add-on for a SEM. For quantitative XRFA the source spectrum has to be known. For its calculation the X-ray production yields Y have been measured for the commonly used tube target materials Mo, Rh and W. The excitation spectra were calculated for a variety of source types and compared with respect to the achievable photon flux and its spectral distribution.
X-ray Fluorescence (XRF) with a scanning electron microscope (SEM) is a valuable completion of the analytical capabilities of SEMs. Small and compact micro-focus x-ray sources are mounted to the microscope chamber, and the x-ray spectra are monitored with conventional EDS systems. Up to now the x-ray tubes used for the micro-focus x-ray sources are equipped with beryllium windows about 100 µm thick. The poly-capillary x-ray lenses have their transmission maximum at photon energies around 10 keV. It drops down in both low- and high-energy ranges. Hence, L-radiation from an Mo or Rh target will be strongly attenuated, and the excitation of fluorescence in the soft x-ray range becomes very ineffective. A new micro-focus x-ray source was developed. It is characterised by a lower self-absorption in the tube target, thin beryllium windows and an x-ray optics having a large distance between its foci and the maximum of transmission at about 5 keV. Thus K line fluorescence of light elements becomes effectively excited by the L-radiation from Mo or Rh tube targets. The detection limit for sodium oxide in glass was found to be below 1 mass%.
A method is proposed to determine the effective detector area for energy-dispersive X-ray spectrometers (EDS). Nowadays, detectors are available for a wide range of nominal areas ranging from 10 up to 150mm2. However, it remains in most cases unknown whether this nominal area coincides with the “net active sensor area” that should be given according to the related standard ISO 15632, or with any other area of the detector device. Moreover, the specific geometry of EDS installation may further reduce a given detector area. The proposed method can be applied to most scanning electron microscope/EDS configurations. The basic idea consists in a comparison of the measured count rate with the count rate resulting from known X-ray yields of copper, titanium, or silicon. The method was successfully tested on three detectors with known effective area and applied further to seven spectrometers from different manufacturers. In most cases the method gave an effective area smaller than the area given in the detector description.
Electron probe microanalysis (EPMA) measurement of thin-film thickness in the nanometre range
(2002)
The thickness of thin films of platinum and nickel on fused silica and silicon substrates has been determined by EPMA using the commercial software STRATAGEM for calculation of film thickness. Film thickness ranged in the order 10 nm. An attempt was made to estimate the confidence range of the method by comparison with results from other methods of analysis. The data show that in addition to the uncertainty of the spectral intensity measurement and the complicated fitting routine, systematic deviation caused by the underlying model should be added. The scattering in the results from other methods does not enable specification of a range of uncertainty, but deviations from the real thickness are estimated to be less than 20%.
The results of an interlaboratory comparison of energy dispersive X-ray microanalysis of TiN0.84 and ZrN were presented. The microprobe group of the German Physical Society (DPG) and the Federal Institute for Materials Research and Testing (BAM) had initiated the interlaboratory comparison. The primary aim was to test modern EDX systems equipped with ultrathin windows concerning the accuracy and reliability of the analysis of compounds containing light elements. The participants from 23 laboratories performed the analysis at different primary energies, in the standard-less mode as well as on the base of own standards, and considering Ti-K or Ti-L in case of TiN0.84. The results show a slight overestimation of the nitrogen content and a large standard deviation from the mean value. Reasons for the scattering of the results are discussed.
Efficiency and response functions were determined for a modern commercial energy-dispersive x-ray spectrometer in the photon energy range 0.1-5 keV using dispersed and undispersed synchrotron radiation. The spectrometer was equipped with an Si(Li) detector crystal, a thin-film window and a digital pulse processor. Monochromatized synchrotron radiation from the PTB VUV radiometry beamline at the electron storage ring BESSY was used for the absolute determination of the detection efficiency with a typical relative uncertainty of 1-2% in the photon energy range 0.1-1.5 keV by direct comparison with calibrated photodiodes. At higher photon energies, the efficiency was found by comparison of the measured and calculated undispersed synchrotron radiation spectrum. The absolute intensity of the synchrotron radiation was known with a relative uncertainty of less than 1%. In the overlapping region, the results from the two independent experiments are in full agreement. The energy dependence of the measured efficiency can be explained only with a detector model assuming that there is no dead layer. A simple model for the effect of incomplete charge collection (ICC) was applied to describe the measured response functions. Consequences of the ICC such as broadening and shift of low-energy peaks and redistribution of counts around 1.84 keV are explained with the model, in accordance with the experimental results.
Measurement and calculation of x-ray production efficiencies for copper, zirconium, and tungsten
(2022)
Electron probe microanalysis (EPMA) is based on physical relations between measured X-ray intensities of characteristic lines and their Xray production efficiency, which depends on the specimen composition. The quality of the analysis results relies on how realistically the physical relations describe the generation and emission of X-rays. Special experiments are necessary to measure X-ray production efficiencies. A challenge in these experiments is the determination of the detection efficiency of the spectrometer as a function of the photon energy. An energy-dispersive spectrometer was used in this work, for which the efficiency was determined at metrological synchrotron beamlines with an accuracy of ±2%. X-ray production efficiencies for the L series and the Kα series of copper and zirconium and for the M and L series of tungsten were determined at energies up to 30 keV in a scanning electron microscope. These experimental values were compared with calculated X-ray production efficiencies using physical relations and material constants applied in EPMA. The objective of the comparison is the further improvement of EPMA algorithms as well as extending the available database for X-ray production efficiencies. Experimental data for the X-ray production efficiency are also useful for the assessment of spectrum simulation software.
Energy dispersive X-ray spectrometry offers the opportunity for fast composition determination of specimens by X-ray fluorescence or electron probe microanalysis. For fundamental parameter based quantification, the knowledge of the detection efficiency of the spectrometer is essential. At low energies the efficiency is strongly influenced by X-ray absorption in the radiation entrance window. State-of-the-art windows consist of polymer foil containing C, N, and O, coated with Al and in some cases with a special B compound. The foil is supported by a Si grid to withstand the atmosphere pressure. The absorption of all these components must be known to describe the detection efficiency.
The transmittance of three types of widely used commercial windows has been measured. Transmittance curves have been fitted by analytical expressions using tabulated mass absorption coefficients. Because tabulated mass absorption coefficients do not consider near edge effects, there are strong deviations between measured and calculated transmittance below 0.6 keV. It is proposed to model the spectrometer efficiency by the measured window transmittance and calculated absorptions from front contact and possible contaminations. This reduces the number of unknown parameters drastically.
The X-ray intensities of the K-, L- and M-lines of copper, zirconium and tungsten have been measured with an energy-dispersive X-ray spectrometer of known efficiency as function of photon energy. X-ray production efficiencies were determined from the measured intensities for Kα- and L-series of Cu and Zr and for the L- and M-series of W. These data were compared to calculated X-ray production efficiencies based on the widely used matrix correction models of Pouchou and Pichoir (XPP) and Bastin (PROZA96).
Our results indicate that a replacement of the stopping power in the PROZA96 algorithm by expressions of Joy and Jablonski has only a minor influence on the calculated X-ray production efficiencies. In contrast, the modifications of the ionization cross-section show a stronger effect. We replaced the ionization cross-sections for K lines of the PROZA96 algorithm with different models.
The results for L- and M-Lines are different. For the L-lines of Cu the original XPP and PROZA96 models show the best agreement while using the Bote cross-sections result in an overestimation. For the Zr-L and W-L1, -L2, -L3 X-ray production efficiencies, the Bote cross-sections lead to a significant improvement compared to all other models. The original XPP model represents the best agreement for the M5 efficiencies but underestimates the M4 efficiencies.
There is no superior model or modification because the parameter sets in the models need to be aligned to each other. However, using the ionization cross-sections of Bote, which are based on quantum mechanical calculations, show promising results in many cases.
High-accuracy film thickness measurements in the range below 100 nm can be made by various complex methods like spectral ellipsometry (SE), scanning force microscopy (SFM), grazing incidence X-ray reflectometry (GIXR), or X-ray fluorescence analysis (XRF). The measurement results achieved with these methods are based on different interactions between the film and the probe. A key question in nanotechnology is how to achieve consistent results on a level of uncertainty below one nanometre with different techniques.
Two different types of thickness standards are realised. Metal film standards for X-ray techniques in the thickness range 10 to 50 nm are calibrated by GIXR with monochromatised synchrotron radiation of 8048 eV. The results obtained at four different facilities show excellent agreement. SiO2 on Si standards for SE and SFM in the thickness range 6 to 1000 nm are calibrated by GIXR with monochromatised synchrotron radiation of 1841 eV and with a metrological SFM. Consistent results within the combined uncertainties are obtained with the two methods. Surfaces and interfaces of both types of standards are additionally investigated by transmission electron microscopy (TEM).