Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (39)
- Zeitschriftenartikel (37)
- Posterpräsentation (11)
- Beitrag zu einem Sammelband (5)
- Beitrag zu einem Tagungsband (3)
- Sonstiges (3)
- Forschungsbericht (1)
Schlagworte
- EPMA (7)
- EDS (6)
- Microanalysis (5)
- X-ray spectrometry (5)
- Electron probe microanalysis (4)
- SEM (4)
- EDX (3)
- X-ray optics (3)
- X-ray spectroscopy (3)
- XRF (3)
- Copper (2)
- Micro-XRF (2)
- Micro-focus-XRF (2)
- Quantitative analysis (2)
- Scanning electron microscopy (2)
- Standardless analysis (2)
- Test material (2)
- Tungsten (2)
- X-ray detectors (2)
- X-ray production efficiency (2)
- X-ray spectrometer (2)
- X-ray tube (2)
- X-rays (2)
- Zirconium (2)
- AES (1)
- Analytical SEM (1)
- Bremsstrahlungspektrum (1)
- Calibration (1)
- Computer programmes (1)
- Depth profiling (1)
- Detection efficiency (1)
- Detection limits (1)
- Detektor (1)
- Detektoren (1)
- EDX-Detektor (1)
- EMPA (1)
- ESMA (1)
- Effective area (1)
- Elektronenstrahl-Mikroanalyse (1)
- Elemental mapping (1)
- Energy dispersive X-ray spectrometry (1)
- Energy dispersive X-ray spectroscopy (1)
- Energy dispersive spectrometry (1)
- Energy-dispersive X-ray spectrometer (EDS) (1)
- Energy-dispersive X-ray spectroscopy (1)
- Geometrical collection efficiency (1)
- Ion beam bevelling (1)
- Laser (1)
- Materials science (1)
- Microfocus x-ray source (1)
- Oberflächenanalyse (1)
- Performance check (1)
- RFA (1)
- Röntgenfluoreszenzanalyse (1)
- Röntgenspektrokopie (1)
- Röntgenspektroskopie (1)
- Schichtdickenmessung (1)
- Secondary fluorescence correction (1)
- Si(Li) detector (1)
- Software (1)
- Spectrometer calibration (1)
- Spectrometer check (1)
- Spekralanalyse (1)
- TEM (1)
- Thickness measurement (1)
- Thin films (1)
- Titanium nitride (1)
- Transmission (1)
- Uncertainties (1)
- WDS (1)
- X-ray analysis (1)
- X-ray detector (1)
- X-ray emission (1)
- X-ray emission yield (1)
- X-ray fluorescence (1)
- X-ray fluorescence analysis (1)
- X-ray production yield (1)
- X-ray tube spectrum (1)
- X-ray yield (1)
- Zirconium nitride (1)
- myXRF at SEM (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (39)
Efficiency and response functions were determined for a modern commercial energy-dispersive x-ray spectrometer in the photon energy range 0.1-5 keV using dispersed and undispersed synchrotron radiation. The spectrometer was equipped with an Si(Li) detector crystal, a thin-film window and a digital pulse processor. Monochromatized synchrotron radiation from the PTB VUV radiometry beamline at the electron storage ring BESSY was used for the absolute determination of the detection efficiency with a typical relative uncertainty of 1-2% in the photon energy range 0.1-1.5 keV by direct comparison with calibrated photodiodes. At higher photon energies, the efficiency was found by comparison of the measured and calculated undispersed synchrotron radiation spectrum. The absolute intensity of the synchrotron radiation was known with a relative uncertainty of less than 1%. In the overlapping region, the results from the two independent experiments are in full agreement. The energy dependence of the measured efficiency can be explained only with a detector model assuming that there is no dead layer. A simple model for the effect of incomplete charge collection (ICC) was applied to describe the measured response functions. Consequences of the ICC such as broadening and shift of low-energy peaks and redistribution of counts around 1.84 keV are explained with the model, in accordance with the experimental results.