Organisationseinheit der BAM
Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources.
Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related
Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials.
Um eine gute Luftqualität in Gebäuden zu erreichen, müssen Reinigungslasten durch Lüften aus Räumen abgeführt bzw. vermieden oder verringert werden. Wird der Luftwechsel verringert, verschlechtert sich die Raumluftqualität, und die Zufriedenheit der Nutzer nimmt ab. An Arbeitsplätzen kann es bei schlechter Luftqualität und der daraus resultierenden Unzufriedenheit zu einer geringeren Produktivität der Beschäftigten kommen. Um die Reinigungslasten und deren Wirkung auf den Raumnutzer überdas Geruchsempfinden zu verringern, ist neben einer messtechnischen Erfassung der Verunreinigungen auch eine sensorische Prüfung in Innenräumen und von Bauprodukten notwendig. In diesem Artikel wird die Entwicklung der Bewertungsmethodik von Gerüchen im Innenraum erläutert und auf Anwendungen eingegangen.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.