Filtern
Dokumenttyp
- Zeitschriftenartikel (2)
- Vortrag (1)
Sprache
- Englisch (3)
Schlagworte
- Ethanol in water (3) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
Ethanol/water solutions as certified reference materials for breath alcohol analyzer calibration
(2010)
The Federal Institute for Materials Research and Testing (BAM), Germany, has issued a series of large volume ethanol in water certified reference materials (CRMs), primarily developed for the calibration of evidential breath alcohol analyzers in Germany. The certified parameter is the ethanol mass concentration at 20 °C. When used in a wet bath simulator, the solutions deliver gas samples that meet the requirements set by the Organization of Legal Metrology for calibration of breathalyzers. The materials were prepared gravimetrically by spiking of ethanol into water in single 5 L units. A complete uncertainty budget for the preparation process has been established. The purity of the commercial ethanol stock solution was identified to be the main source of uncertainty. For stability and homogeneity measurements and for the verification of the gravimetric mass concentration of the CRMs, a robust high-precision gas chromatography, with flame-ionization detection method for ethanol determination in aqueous samples was developed and validated. The good performance of this method has been demonstrated in several international comparisons organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry at the International Bureau of Weights and Measures.
Supplementary comparison study - measurement capabilities for the quantification of ethanol in water
(2022)
The accurate quantification of ethanol in water is essential for forensic applications such as blood and breath alcohol testing and for commercial applications such as the assessment of alcoholic beverages.
The intercomparison EURAMET.QM-S14 is part of a capacity building project named ALCOREF “Certified forensic alcohol reference materials”
that is running within the European Metrology Programme for Innovation and Research (EMPIR). The intercomparison should allow project partners and other interested National Metrology Institutes (NMIs) and Designated Institutes (DIs) to benchmark their analytical methods for the quantification of ethanol in water. The study plan was agreed by the European Association of National Metrology Institutes (EURAMET) Subcommittee Bio- and Organic Analysis (SCBOA) and the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) in February and April 2019, respectively. The intercomparison was coordinated by BAM. Two concentration levels relevant for the calibration and verification of evidential breath alcohol analysers were distributed to study participants. Fifteen institutes from 15 countries registered for the intercomparison and returned results. Participants mostly applied gas chromatography with flame ionisation detection (GC-FID) or mass spectroscopy (GC-MS), one participant used titrimetry and one participant employed a test bench for breath analyser calibration (“bubble train”). Participants did either in-house purity assessment of their commercial ethanol calibrants by Karl-Fischer titration, chromatographic methods, quantitative nuclear magnetic resonance spectroscopy (qNMR) and/or density measurements; or they used ethanol/water Certified Reference Materials (CRMs) from NMIs/DIs for calibration.
CCQM OAWG agreed to use a consensus value from participants results that utilizes the reported uncertainties as Key Comparison Reference Value (KCRV). The Gaussian Random effects model with Hierarchical Bayesian solution (HB-REM) is a reasonable approach in this case. The KCRVs and Degrees of Equivalence (DoEs) were calculated with the NIST consensus builder version 1.2 Hierarchical Bayes procedure.
Successful participation in the interlaboratory comparison has demonstrated the capabilities in determining the mass fraction of ethanol in aqueous matrices in the range 0.1 mg/g to 8 mg/g. Fourteen out of 15 participants have successfully quantified both samples, one participant successfully quantified only the lower-level (0.6 mg/g) sample.