Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (21)
- Beitrag zu einem Sammelband (2)
- Vortrag (2)
- Beitrag zu einem Tagungsband (1)
- Forschungsbericht (1)
Schlagworte
- Fluorescence (7)
- Spectral correction (6)
- Standard (6)
- Quality assurance (4)
- Emission (3)
- Spectral fluorescence standard (3)
- Traceability (3)
- Calibration tool (2)
- Dye (2)
- Glass (2)
- Method comparison (2)
- Photoluminescence (2)
- Uncertainty (2)
- 13C NMR (1)
- 29Si NMR (1)
- Amphiphiles (1)
- Antibody (1)
- Applikationsbereiche (1)
- Arsenolipids (1)
- Aspergillus (1)
- Asymmetric catalysis (1)
- Biosynthesis (1)
- Block copolymers (1)
- Boehmite (1)
- CCQM (1)
- CCQM key comparison (1)
- Calibration (1)
- Cationic photocuring (1)
- Cis-ZEN (1)
- Conjugate (1)
- Cycloaliphatic epoxy oligosiloxane (1)
- Depletion kinetics (1)
- ESI-MS/MS (1)
- Emission standards (1)
- Empfindlichkeit (1)
- Enantioselective Hydrogenation (1)
- Epoxy conversion degree (1)
- Excitation (1)
- Explosive (1)
- Fluorescence intensity (1)
- Fluorescence intensity standards (1)
- Fluorescence standard (1)
- Fluorescence standards (1)
- Fluoreszenzstandards (1)
- Fluorometrie (1)
- Fluorometry (1)
- Folic acid (1)
- Fusarium (1)
- HPLC-ICP-MS/HR-MS (1)
- HRMS (1)
- Hapten immunoassay (1)
- Hauptkomponenten-Analyse (1)
- Hr- and Solid State NMR-Spectroscpy (1)
- Hydrogenation (1)
- Instrument performance validation (1)
- Intensity standard (1)
- Key comparision (1)
- Kinetics (1)
- LC-MS/MS (1)
- Liquid standard (1)
- Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) (1)
- Mess-Unsicherheit (1)
- Mycotoxin (1)
- N-vinyl pyrrolidone (1)
- NMR (1)
- Nanocomposite (1)
- Phase I metabolism (1)
- Powder Diffractometry (1)
- Purity assessment (1)
- Quantitative NMR (1)
- Quantum yield (1)
- Radiometrische Terminologie (1)
- Radiometry (1)
- Reaction mechanisms (1)
- Real-time infrared spectroscopy (1)
- Reference material (1)
- Reversible addition/fragmentation chain transfer (RAFT) (1)
- Rhizopus (1)
- Rhodium (1)
- Rhodium-Phosphor-Complex (1)
- Rückführbarkeit (1)
- Selektivität (1)
- Si-O-C bonds (1)
- Silica-cellulosic composites (1)
- Sol-gel derived silica (1)
- Spectral radiance (1)
- Spectral responsivity (1)
- Spectrofluorometer (1)
- Structure (1)
- Synthesis (1)
- TATP (1)
- Triacetone triperoxide (1)
- Zearalenone (1)
- qNMR (1)
Organisationseinheit der BAM
- 6 Materialchemie (3)
- 6.3 Strukturanalytik (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- 1.8 Umweltanalytik (1)
- 4 Material und Umwelt (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
Eingeladener Vortrag
- nein (2)
Triacetone triperoxide (TATP), an improvised explosive, is a potential security threat because of its cost-efficient synthesis and the difficulty in detecting it. A highly selective antibody could provide the necessary specificity to the detection process. To obtain antibodies, a hapten made from acetone, hydrogen peroxide, and 7-oxooctanoic acid has been designed, synthesized, and confirmed by NMR that displays the utmost similarity to the analyte. The single-crystal X-ray structures of the solvated species TATP·methanol (1:1) and the TATP derivate were determined. In both compounds, the molecules exhibit D3 symmetry and adopt a twisted boat-chair conformation. The hapten was coupled to bovine serum albumin, and mice were immunized. An immune response against TATP was elicited, and selective antibodies were detected in the mouse serum, which should be very useful for the development of a TATP biosensor system. An ELISA with a limit of detection for TATP of 65 µg L-1 is shown.
The need for the traceable characterization of fluorescence instruments is emphasized from a chemists point of view, focusing on spectral fluorescence standards for the determination of the wavelength- and polarization-dependent relative spectral responsivity and relative spectral irradiance of fluorescence measuring systems, respectively. In a first step, major sources of error of fluorescence measurements and instrument calibration are revealed to underline the importance of this issue and to illustrate advantages and disadvantages of physical and chemical transfer standards for generation of spectral correction curves. Secondly, examples for sets of traceable chemical emission and excitation standards are shown that cover a broad spectral region and simple procedures for the determination of corrected emission spectra with acceptable uncertainties are presented. With proper consideration of the respective measurement principle and geometry, these dye-based characterization procedures can be not only applied to spectrofluorometers but also to other types of fluorescence measuring systems and even to Raman spectrometers.
The inter-instrument, inter-laboratory, and long-term comparability of fluorescence data requires the correction of the measured emission and excitation spectra for the wavelength- and polarization-dependent spectral irradiance of the excitation channel at the sample position and the spectral responsivity of the emission channel employing procedures that guarantee traceability to the respective primary standards. In this respect the traceability chain of fluorometry is discussed from a radiometrists point of view. This involves, in a first step, the realization of the spectral radiance scale, based on the blackbody radiator and electron storage ring, and the spectral responsivity scale, based on the cryogenic radiometer and their control via key comparisons of the national metrology institutes. In a second step, the characterization including state-of-the art uncertainties of the respective source and detector transfer standards such as tungsten strip lamps, integrating sphere radiators, and trap detectors used to disseminate these radiometric quantities to users of spectroscopic techniques is presented.
To improve the reliability of fluorescence data in the life and material sciences and to enable accreditation of fluorescence techniques, standardization concepts are required that guarantee and improve the comparability of fluorescence measurements. At the core of such concepts are simple and evaluated fluorescence standards for the consideration of instrument-specific spectral and intensity distortions of measured signals and for instrument performance validation (IPV). Similarly in need are fluorescence intensity standards for the quantification from measured intensities and for signal referencing, thereby accounting for excitation light-induced intensity fluctuations. These standards should be preferably certified, especially for use in regulated areas like medical diagnostics. This encouraged us to develop liquid and solid standards for different fluorescence parameters and techniques for use under routine measurement conditions in different formates. Special emphasis was dedicated to the determination and control of the spectral responsivity of detection systems, wavelength accuracy, homogeneity of illumination, and intensity referencing for e.g. spectrofluorometers, fluorescence sensors and confocal laser scanning fluorescence microscopes. Here, we will present design concepts and examples for mono- and multifunctional fluorescence standards that provide traceability to radiometric units and present a first step towards a toolbox of standards.
With the Calibration Kit Spectral Fluorescence Standards BAM-F001BAM-F005, we developed a simple
tool for the characterization of the relative spectral responsivity and the long-term stability of the emission channel of
fluorescence instruments under routine measurement conditions thereby providing the basis for an improved comparability
of fluorescence measurements and eventually standardization. This first set of traceable fluorescence standards,
which links fluorescence measurements to the spectral radiance scale in the spectral range of 300770 nm and has been optimized for spectrofluorometers, can be employed for different measurement geometries and can be adapted to different fluorescence techniques with proper consideration of the underlying measurement principles.
Arsenolipids (AsL) of the type arsenic-containing fatty acids (AsFA) and hydrocarbons (AsHC) are natural organoarsenic compounds present in high abundance in seafood. Since little is known about their toxicity, there is a significant concern about their health risk. Here we report the synthesis of two new AsL and their identification in fish by liquid chromatography (LC) coupled simultaneously to inductively coupled plasma mass spectrometry (ICP-MS) and to high resolution mass spectrometry (HR-MS). The molecular structure was elucidated on the basis of their exact mass and their product ion mass spectra. One of the synthesized AsL has been already identified in fish samples, meanwhile, the other arsenolipid is reported here as a natural product in fish.
In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.