Acoustic emission (AE) sources caused by partial discharges in solid dielectric devices like transition joints or outdoor terminations are investigated. Together with a prepared high voltage cable end this device forms a multilayer structure. The hypothesis is that due to the high damping of polymeric insulation materials no AE signal can be detected on the surface of the prescribed structures. An analytical technique is used to determine the transmission for a typical multilayer insulation. For quantitative computations it is necessary to know the material properties such as complex Young´s modulus, density and the Poisson´s ratio. Since the properties found in the literature were not fully satisfactory, measurements had to be done. The experimental setup and the results are shortly presented. Finally it will be shown that the transmission path plays not the significant role as was assumed in the beginning.
The diffuse field assumption employed in basic statistical energy analysis (SEA) and in statistical room acoustics is violated for source and receiver positions close to boundaries or discontinuities. A simple approach is proposed to include the correction initially suggested by Waterhouse based on spherical Bessel functions in SEA predictions for rectangular rooms. With this modification the SEA results will be augmented by a position dependence and an additional frequency dependence. The approach is applied and demonstrated also for plate-like structures with different boundary conditions. An analytical solution is shown for the corner position on a simply supported plate and for edge positions on plates with more complex boundary conditions. The validity of the approach is confirmed by means of comparisons with modal analysis and finite element calculations.
The diffuse field assumption employed in Statistical Energy Analysis (SEA) and in statistical
room acoustics is violated for source and receiver positions close to boundaries or discontinuities.
An approach is suggested to include the correction made by Waterhouse based on
spherical Bessel functions in SEA predictions. With this modification the SEA results will be
augmented by a position dependence and an additional frequency dependence. The approach
is extended and demonstrated for plate-like structures with different boundary conditions. The
validity of the approach is confirmed by means of comparisons with modal analysis and finite
element calculations.
Partial discharges may cause damage to electrical insulation of high voltage equipment. They initiate elastic waves in the insulating material, e.g. in the stress cone of an outdoor termination. Localisation of the origin of such elastic waves can help to predict serious damaging processes in the electrical insulation. In order to measure and evaluate the wave propagation effects in typical multilayered elastomeric structures, knowledge of the material properties is required. The propagating velocity and the attenuation of longitudinal waves are important parameters. Values for these quantities found in the literature were not appropriate. Therefore, for cross-linked polyethylene (XLPE) and cured liquid silicone rubber (LSR), the longitudinal wave velocity and the attenuation were evaluated in the temperature interval from -20°C to 50°C and in the frequency range from 200 kHz to 600 kHz using a two-sample ultrasound technique. The loss factor was determined from these measured quantities. Additionally, low frequency Dynamic Mechanical Thermal Analysis (DMTA) was applied to investigate LSR and XLPE in a temperature interval between -100 and 50°C and to check qualitatively the ultrasound data.