Evaluation of high spatial resolution imaging of magnetic stray fields for early damage detection
(2017)
The paper discusses the evaluation of elastic and plastic strain states in two low-carbon steels of the same steel group with high spatial resolution GMR (giant magneto resistance) sensors. The residual stress distributions of tungsten inert gas welded plates were determined by means of neutron diffraction as a reference. The normal component of local residual magnetic stray fields arise in the vicinity of the positions of maximum stress. The experiments performed on flat tensile specimen indicate that the boundaries of plastic deformations are a source of stray fields. The spatial variations of magnetic stray fields for both the weld and the tensile samples are in the order of the earths magnetic field.
An internal project at BAM (Bundesanstalt für Materialforschung und -prüfung) pursue the goal to develop methods and models to investigate ageing of CFRP (carbon fiber reinforced plastic) composites pressure vessels. One main challenge is the application of appropriate testing methods for detecting the influences of pressure cycles and creep behavior on the material. This contribution presents results we achieved using conventional eddy current testing (ET) and high frequency ET. Before investigating pressure vessels, we studied test samples with artifcial defects. Here, we could show that also conventional ET with low frequencies are useable for CFRP samples which have at bottom holes of different size and depth. On the basis of the received results we deployed conventional ET besides high-frequency applications in order to investigate pressure vessels of different material combinations like steel-CFRP,
Aluminum-CFRP and synthetics-CFRP. The thickness of the CFRP varies from 4 mm up to 8 mm. Here, we could detect both defects in the metal liner and in the CFRP.
Electromagnetic methods are widely used in Non-destructive Testing industries (NDT). In order to meet the requirements, safety-relevant products and structures have to be tested reliably during production or within subsequent maintenance cycles. For this purpose industrial users call for adapted testing methods which allow the detection of relevant defects such as cracks and pore in ferromagnetic or conductive materials. Automated testing systems and the application of sensor arrays are of great interest in order to enhance inspection quality and to decrease testing time and costs. Magneto resistance (MR) sensors like giant magneto resistance (GMR) or tunnel magneto resistance sensor (TMR) have proofed their suitability in many NDT-applications due to their extraordinary properties which combine high field sensitivity, a high spatial resolution and low costs. Due to their small size these sensors can be useful – in addition to the pure detection task – for a more detailed defect characterization and defect reconstruction providing defect size, orientation and geometry. This chapter gives a brief introduction of electromagnetic testing methods, i.e., magnetic particle inspection (MPI) and eddy current testing (ET), followed by two different approaches for which MR sensor arrays were successfully adapted.
Main concept of magnetism and, therefore, of magnetic imaging can be subdivided into different levels, macroscopic, magnetic domain, and atomic. While conventional sensor solutions cover only the macroscopic level, the spatial resolution of GMR (Giant Magneto Resistance) sensors go down to the domain scale. In addition, those low cost sensors are well suited for automotive and industrial applications, particularly high-speed solutions. Main reason is their outstanding performance in terms of high spatial resolution, high accuracy, high bandwidth combined with field sensitivity, energy efficiency and durability.
In contrast to industrial use, down to the present day GMR sensors do not get beyond scientific scope in case of non-destructive testing (NDT) applications. Nevertheless, there are scientific and industrial NDT applications in which adapted GMR sensor can be promising compared to the conventional NDT methods.
This contribution summarizes findings at the BAM over the last decade which demonstrates the preeminent properties of GMR-based testing solutions. This comprises the active and passive testing of different materials with hidden defects and flaws near geometric boundaries like edges where conventional methods meet their limits. Another promising application for adapted GMR sensors is the characterization of magnetic materials, where the sensors provide additional information on microstructure, mechanical stress state, phase transformations and their interaction with magnetic fields. The examples show the need and benefit of NDT adapted GMR sensors.
The use of composite pressure vessels instead of conventional vessels made of steel or aluminum grew strongly over the last decade. The reason for this trend is the tremendous weight saving in case of composite vessels. However, the long-time behavior is not fully understood for filling and discharging cycles and creep strength and their influence on the CFRP coating (carbon fiber reinforced plastics) and the internal liner (steel, aluminum, or plastics) [1]. The CFRP ensures the pressure resistance while the inner liner is used as container for liquid or gas. To overcome the missing knowledge of ageing BAM started an internal project to investigate degradation of these material systems [2]. Therefore, applicable testing methods are needed. Normally, high-frequency eddy current testing (HF-ET, f > 10 MHz) is deployed for CFRP due to its low conductivity of the fiber, which is in the order of 0.01 MS/s, and the capacitive coupling between the fibers. Nevertheless, in some cases conventional ET can be applied. We show a concise summary of studies on the application of conventional ET of composite pressure vessels.
Magneto resistive (MR) sensors are suited for a wide range of different applications. Especially due to their small sizes and their frequency-independent behaviour, they are eligible candidates for non-destructive testing methods where high spatial resolution is required. The use of specialized magnetic field probes enables not only a defect evaluation, but also a localized characterization of ferromagnetic materials.
This paper presents some NDT (non-destructive testing) examples concerning magnetic flux leakage applications (MFL) and eddy current testing (ET). For MFL-testing we used an NDT-adapted GMR (Giant MR) sensor array for the detection of small inclusions in thin steel sheets. We also investigated the effects of microstructure on magnetic properties using GMR sensors. The ET-example describes an MR array probe consisting of 32 MR-elements, an ASIC, subsequent readout components and a one-wire excitation to generate eddy currents inside the material (developed in the EU-funded IMAGIC-project, 2011-2014, 7th Framework Programme). Using this MR-probe we achieved results with a better spatial resolved defect detection of neighbouring boreholes compared to “conventional” ET-probes.
Magneto resistive (MR) sensors are suited for a wide range of different applications. Especially due to their small sizes and their frequency-independent behaviour, they are eligible candidates for non-destructive testing methods where high spatial resolution is required. The use of specialized magnetic field probes enables not only a defect evaluation, but also a localized characterization of ferromagnetic materials.
This paper presents some NDT (non-destructive testing) examples concerning magnetic flux leakage applications (MFL) and eddy current testing (ET). For MFL-testing we used an NDT-adapted GMR (Giant MR) sensor array for the detection of small inclusions in thin steel sheets. We also investigated the effects of microstructure on magnetic properties using GMR sensors. The ET-example describes an MR array probe consisting of 32 MR-elements, an ASIC, subsequent readout components and a one-wire excitation to generate eddy currents inside the material (developed in the EU-funded IMAGIC-project , 2011-2014, 7th Framework Programme). Using this MR-probe we achieved results with a better spatial resolved defect detection of neighbouring boreholes compared to “conventional” ET-probes.
In vielen Bereichen der Technik haben Konstruktionen unter Einsatz von CFK-Bauteilen und Komponenten die klassischen Metalle abgelöst. Die zerstörungsfreie Prüfung solcher CFK-Bauteile gewinnt somit zunehmend an Bedeutung. Ein mögliches Prüfverfahren ist dabei die Wirbelstromprüfung. Aufgrund der relativ geringen elektrischen Leitfähigkeit von CFK-Komponenten kommt hierbei häufig die sogenannte HF-Wirbelstromprüfung zum Einsatz.
In verschiedenen Untersuchungen der BAM konnten jedoch auch mit Wirbelstromprüfsystemen in niedrigen Frequenzbereichen gute Ergebnisse erzielt werden. Um die Möglichkeiten und Grenzen dieser konventionellen Wirbelstromprüfung auszuloten, wurden Messungen an Versuchskörpern durchgeführt, welche bereits bei der Validierung der Blitz- und Lock-in-Thermografie für neue Verfahrensnormen erfolgreich eingesetzt wurden. Ein Typ dieser Versuchskörper sind Flachproben aus CFK von 6 mm Dicke. In diesen wurden Flachbodenbohrungen mit Durchmessern zwischen 4 mm und 24 mm eingebracht. Die Restwandstärken liegen zwischen 0,06 mm und 3,66 mm. Ein weiterer CFK-Versuchskörper hat die Geometrie eines Stufenkeiles. Bei verschiedenen Stufenkeilen sind Wanddicken zwischen 1,4 mm und 5,4 mm realisiert worden. In diesen wurden künstliche quadratische Delaminationen mit Kantenlängen zwischen 2 mm und 20 mm eingebracht. Die Ergebnisse der Wirbelstromprüfung werden denen der aktiven Thermografie gegenübergestellt.
Zur Nachbildung von Kompositwerkstoffen wurden die flachen Versuchskörper mit geeigneten Versuchskörpern aus Aluminium und Stahl kombiniert. Die Wirbelstromprüfungen wurden mit einem handelsüblichen Prüfgerät im Frequenzbereich zwischen 500 Hz und 3 MHz und entsprechend angepassten Sensoren durchgeführt.