There is a high demand of monitoring in the era of QbD in industrial scale require new approaches to gain data rapidly and of sufficient quality in real time. Raman spectroscopy technology has great potential but not yet shown it fully in process on-line monitoring due to limitations such as i) uncomplete separation between cells and growth media alone, ii) general weak Raman signals of analytes in complex solutions and iii) strong background signals such as the auto-fluorescence, cosmic rays and surrounding lights overlapping the weak Raman signals. Here we demonstrate a Proof-of-Concept on an the example lactic acid bacteria process using a Streptococcus thermophiles fermentation. Results from three different Raman approaches are presented: 1) Time-Gated Raman Spectroscopy (TG-Raman), 2) Surface Enhanced Raman Spectroscopy (SERS) and 3) Raman process spectroscopy with NIR excitation combined with multivariate data analysis (MVDA) using Principal Component Analysis (PCA) and Partial Least Squares Regression (PLSR).
A major industrial reaction based on homogeneous catalysis is hydroformylation for the production of aldehydes from alkenes and syngas. Hydroformylation in microemulsions, which is currently under investigation at Technische Universität Berlin on a mini-plant scale, was identified as a cost efficient approach which also enhances product selectivity. Herein, we present the application of online Raman spectroscopy on the reaction of 1-dodecene to 1-tridecanal within a microemulsion. To achieve a good representation of the operation range in the mini-plant with regard to concentrations of the reactants a design of experiments was used. Based on initial Raman spectra partial least squares regression (PLSR) models were calibrated for the prediction of 1-dodecene and 1-tridecanal. Limits of predictions arise from nonlinear correlations between Raman intensity and mass fractions of compounds in the microemulsion system. Furthermore, the prediction power of PLSR models becomes limited due to unexpected by-product formation. Application of the lab-scale derived calibration spectra and PLSR models on online spectra from a mini-plant operation yielded promising estimations of 1-tridecanal and acceptable predictions of 1-dodecene mass fractions suggesting Raman spectroscopy as a suitable technique for process analytics in microemulsions.
The growing need to implement sensors such as NIR or Raman spectroscopy for the in-situ monitoring of bioprocesses which follows the standards of Quality by Design is either restricted by the impact of the huge water signal or by a disturbing fluorescence background originating from compounds in the culture media. Furthermore, the characterization of the bioprocess samples is challenging due to changing conditions in course of cultivation.
Here we evaluate two different process-suitable Raman spectroscopic approaches, namely time-gated Raman which bears the potential to extract the Raman signal from the fluorescence background, and cw- Raman with NIR excitation in combination with Surface Enhanced Raman Spectroscopy- (SERS) to investigate cell-free supernatants of Escherichia coli sampled over the course of a cultivation. A confocal Raman microscope was used as a reference for the process devices. The concentration of the analytes, glucose, acetate as well as metabolites such as cAMP, AMP and amino-acids were determined by offline by High-Performance Liquid Chromatography (HPLC) to serve as reference for the calibration of the Raman and SERS spectral data.
Multivariate evaluation of the Raman and SERS spectra by Partial Least Squares Regression (PLSR) yielded for most of the analytes robust correlations at each sampling point. Repeated investigation of the off-line samples over a larger experimental period suggested not only a high reliability of the Raman data in general but also a high repeatability of the SERS experiments. Similar spectral features in different quality and signal/noise ratios were measured with all three set-ups. Major results of the comparison of the different Raman spectroscopic approaches and their combination with SERS are summarized and conclusions are drawn on which approach provides the most accurate concentration data among the target analytes.
Acknowledgement
The authors kindly thank Mario Birkholz (IHP, Frankfurt (Oder), Germany) for the opportunity to use a confocal Raman microscope, Alex Bunker and Tapani Viitala (Division of Pharmaceutical Biosciences, Centre for Drug Research, University of Helsinki, Finland).
A process spectroscopic approach for the monitoring of microplastics in environmental samples
(2018)
The potential of Raman and NIR process-spectroscopic as a rapid approach for the estimation of microplastics (MP) in soil matrix were tested. For this purpose, artificial MP/soil mixture samples consisting of standard soils or sand with defined ratios of MP (0,5 – 10 mass% polymer) from polyethylene (PE), polypropylene (PP), polystyrene (PS) and polyethylene terephthalate (PET) were prepared. MP particles with diameters < 2 mm and < 125 µm were obtained from industrial polymer pellets after cryo-milling. Spectra of these mixtures were collected by (i) a process FT-NIR spectrometer equipped with a reflection probe, (ii) by a cw-process Raman spectrometer and (iii) by a time-gated Raman spectrometer using fiber-optic probes. The evaluation of process-spectra was performed by chemometric methods. Whereas MP could be detected by Raman spectroscopy in coastal sand at 0.5 mass%, in standard soil detection of MP was limited to 10 – 5 mass% with the large fraction, but samples containing particles of the 125µm mass-fraction yielded no positive result at all. One reason for the lacking sensitivity could be fluorescence by soil organic matter and thus, in a next test time-gated Raman spectroscopy was applied. However, although being indeed more sensitive to the small particles this method failed at MP < 5 mass% indicating that fluorescence was not the major problem. Finally, FT-NIR was tested. Depending on the polymer, MP contents of 0,5 or 1 mass%, respectively, could be detected in standard soils and polymers identified. Furthermore, this approach could be used for the investigation of mixtures of up to four polymers and in real-world samples from bio-waste fermenter residues.
The authenticity of objects and artifacts is often
the focus of forensic analytic chemistry. In document fraud
cases, the most important objective is to determine the
origin of a particular ink. Here, we introduce a new
approach which utilizes the combination of two analytical
methods, namely Raman spectroscopy and laser-induced
breakdown spectroscopy (LIBS). The methods provide
complementary information on both molecular and elemental
composition of samples. The potential of this hyphenation
of spectroscopic methods is demonstrated for ten blue
and black ink samples on white paper. LIBS and Raman
spectra from different inks were fused into a single data
matrix, and the number of different groups of inks was
determined through multivariate analysis, i.e., principal
component analysis, soft independent modelling of class
analogy, partial least-squares discriminant analysis, and
support vector machine. In all cases, the results obtained
with the combined LIBS and Raman spectra were found to
be superior to those obtained with the individual Raman or
LIBS data sets.
Raman spectroscopy for online monitoring of a homogeneous hydroformylation process in microemulsion
(2021)
An important industrial reaction is hydro¬formylation for the production of aldehydes from alkenes and syngas on the basis of homogeneous catalysis. The main cost factors of the processes currently used are product selectivity and the loss of the catalysts used. Therefore, various concepts for the hydroformylation of long-chain olefins have been developed, including hydroformylation in microemulsions, which is being investigated on a mini-plant scale at the Technical University of Berlin [1]. In this study, online Raman spectroscopy of the reaction of 1-dodecene to 1-tri¬decanal in a microemulsion was performed [2]. First, an experimental design was used to obtain a good representation of the operating range in the mini plant with respect to the concentrations of five reactants in a laboratory setup [3]. Based on the Raman spectra, Partial Least Squares (PLS) models for the prediction of 1-dodecene and 1-tride-decanal were calibrated and with these the reactions were predicted on a laboratory scale. In the next step, the PLS models were applied to online spectra from a mini-plant. This resulted in promising estimates of 1-tridecanal and acceptable predictions of 1-dodecene mass fractions. The predictive power of PLS models in this particular case was limited by unexpected by-product formation which, however, can easily be compensated by an extended calibration. Hence, Raman spectroscopy is a promising technique for process analysis in microemulsions.
The interaction of microcroplastics (MP) with dissolved organic matter, especially humic substances, is of great importance in understanding the behavior of microplastics in aquatic ecosystems. Surface modification by humic substances plays an essential role in transport and interaction of MP with abiotic and biotic components. Previous studies on the interaction between MP and humic substances were largely based on a model compound, humic acid (Sigma-Aldrich). In our work, we therefore investigated the interaction of natural organic matter (NOM) sampled from a German surface water with low-density polyethylene particles (LDPE). Highpressure size exclusion chromatography (HPSEC) and UV/vis absorption and fluorescence spectroscopy were used to characterize the incubation solutions after modifications due to the presence of LDPE, and Raman spectroscopy was used to characterize the incubated microplastics. While the studies of the solutions generally showed only very small effects, Raman spectroscopic studies allowed clear evidence of the binding of humic fractions to MP. The comparison of the incubation of NOM and a lignite fulvic acid which also was tested further showed that specific signatures of the humic substances used could be detected by Raman spectroscopy. This provides an elegant opportunity to conduct broader studies on this issue in the future.