A commercially available airbrush gun as a new source for spray ionization is presented. It is best operated employing moderate stagnation pressures, resulting in a sonic gas flow. A mass spectrometric investigation on the amino acid lysine and several peptides reveals that this inexpensive approach results in reproducible mass spectra. The ion patterns strongly resemble the results from other studies obtained with custom made sonic spray vaporizers. The patterns as well resemble the mass spectra recorded with electrospray devices. For a better understanding of the vaporization process, the mass spectrometry experiments are accompanied by laser induced fluorescence experiments. Inverse Abel transform of the obtained fluorescence maps allows the determination of the full 3D distribution of the spray cone. Furthermore, via exploitation of the solvatochromism of the used dye the solvation state distribution can be visualized. In addition, expansion parameters like droplet size and velocity are obtained by laser stroboscopy. The experiments demonstrate that the analyte is hardly desolvated throughout the expansion. This indicates a subsequent vaporization of the residual solvent in the intermediate pressure region of the mass spectrometer.
Methods for the determination of boron in various matrices described in the literature usually employ complexing agents like mannitol to retain the volatile boron species during matrix evaporation steps. However, also relatively high boron recoveries from silicon containing samples have been reported when no complexing agents were added to the digestion acids. The mechanism behind this matrix-dependant recovery has been investigated by studying the boron recovery in the analysis of solar grade silicon. It was found that the NH4+ ion formed by the reduction of nitric acid during sample digestion is responsible for the higher recovery of boron, which leads to a possible analysis method without the use of complexing agents if the sample preparation procedure is carefully optimized.
A method for the determination of 22 trace impurities in solar grade silicon after dissolution in a mixture of HF and HNO3 and subsequent matrix evaporation is reported. The presented method involves a simple, inexpensive, one-vessel sample preparation apparatus design. The recoveries of B, Na, Mg, Al, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Mo, Sb, W, and Tl at 250 µg kg-1 level are in the range of 93 to 108%. After careful selection of monitored isotopes and their respective resolutions, a sector field mass spectrometer has been used to carry out the measurements. Limits of determination down to 120 ng kg-1 have been obtained using a calibration by three-point standard addition. The method was tested on diluted NIST SRM 57b silicon powder as well as on synthetic test samples and also applied successfully on raw solar grade silicon samples in an interlaboratory comparison including NAA.
A novel method for predictions of the sound pressure distribution in acoustic levitators is based on a matrix representation of the Rayleigh integral. This method allows for a fast calculation of the acoustic field within the resonator. To make sure that the underlying assumptions and simplifications are justified, this approach was tested by a direct comparison to experimental data. The experimental sound pressure distributions were recorded by high spatially resolved frequency selective microphone scanning. To emphasize the general applicability of the two approaches, the comparative studies were conducted for four different resonator geometries. In all cases, the results show an excellent agreement, demonstrating the accuracy of the matrix method.
One major drawback of matrix-assisted laser desorption/ionization (MALDI) is still the relatively poor pulse-to-pulse reproducibility of the signal intensity. This problem, caused by insufficient homogeneity in the matrix/analyte co-crystallization, is usually circumvented by averaging the detected ion intensity over several shots. However, during the consecutive laser pulses, the applied matrix gets depleted and only a number of subsequent experiments can be done on the same sample spot. In order to achieve the desired long-term stability in combination with a sufficient pulse-to-pulse reproducibility, recently liquid MALDI matrices have been introduced. This contribution demonstrates the promising combination of liquid matrices with high repetition rate lasers for atmospheric pressure MALDI (AP-MALDI). To demonstrate the robustness of the new approach, two different kinds of liquid matrices were used in combination with both a typical flashlamp pumped 15 Hz laser and a diode pumped solid state laser operated at 5 kHz. The latter showed a stable ion signal over more than 3,500,000 consecutive laser pulses.
High repetition rate laser-induced breakdown spectroscopy using acousto-optically gated detection
(2014)
This contribution introduces a new type of setup for fast sample analysis using laser-induced breakdown spectroscopy (LIBS). The novel design combines a high repetition rate laser (up to 50 kHz) as excitation source and an acousto-optical modulator (AOM) as a fast switch for temporally gating the detection of the emitted light. The plasma radiation is led through the active medium of the AOM where it is diffracted on the transient ultrasonic Bragg grid. The diffracted radiation is detected by a compact Czerny-Turner spectrometer equipped with a CCD line detector. Utilizing the new combination of high repetition rate lasers and AOM gated detection, rapid measurements with total integration times of only 10 ms resulted in a limit of detection (LOD) of 0.13 wt.% for magnesium in aluminum alloys. This short integration time corresponds to 100 analyses/s. Temporal gating of LIP radiation results in improved LODs and consecutively higher sensitivity of the LIBS setup. Therefore, an AOM could be beneficially utilized to temporally detect plasmas induced by high repetition rate lasers. The AOM in combination with miniaturized Czerny-Turner spectrometers equipped with CCD line detectors and small footprint diode pumped solid state lasers results in temporally gateable compact LIBS setups.