Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (179) (entfernen)
Schlagworte
- ICP-MS (12)
- LIBS (12)
- ELISA (8)
- LC-MS/MS (8)
- Laser ablation (8)
- Speciation (7)
- Acoustic levitation (6)
- Laser induced plasma (5)
- Laser-induced breakdown spectroscopy (5)
- Nanoparticles (5)
- Traceability (5)
- Caffeine (4)
- Calibration (4)
- Copper (4)
- Fluorescence (4)
- Immunoassay (4)
- Ionization (4)
- LA-ICP-MS (4)
- SEM (4)
- Water (4)
- XRF (4)
- Ambient mass spectrometry (3)
- Antibody (3)
- Bisphenol A (3)
- Carbamazepine (3)
- Characterization (3)
- EDS (3)
- Graphite furnace (3)
- HR-CS-MAS (3)
- High resolution (3)
- In-situ (3)
- Inductively coupled plasma mass spectrometry (ICP-MS) (3)
- Isotope dilution analysis (3)
- Laser-induced plasma (3)
- Levitated droplets (3)
- MALDI (3)
- Photodegradation (3)
- Pollen (3)
- Polymer (3)
- Raman spectroscopy (3)
- Single particle ICP-MS (3)
- Surface water (3)
- SyXRD (3)
- Synchrotron radiation (3)
- Uncertainty (3)
- X-Ray diffraction (3)
- Abwasser (2)
- Bioconjugation (2)
- Cell (2)
- Cells (2)
- Cement hydration (2)
- Chemical analysis (2)
- Chemometrics (2)
- Crystallization (2)
- DPSS laser (2)
- ESI-TOF-MS (2)
- Electrochemical oxidation (2)
- Emission spectroscopy (2)
- Fenton (2)
- Gadolinium (2)
- Gadolinium-based contrast agents (2)
- HPLC (2)
- HPLC-ICP-MS (2)
- High repetition rate (2)
- Hydrophilic interaction chromatography (HILIC) (2)
- Imaging (2)
- In vitro (2)
- Isotope dilution (2)
- Katalysator (2)
- Lithium (2)
- Magnesium (2)
- Mass spectrometry (2)
- Metabolism (2)
- Micropollutants (2)
- Milk (2)
- Multivariate statistics (2)
- NEXAFS (2)
- Nanoparticle (2)
- Optical emission spectroscopy (2)
- Photooxidation (2)
- Plasma tomography (2)
- Polymorphism (2)
- Polystyrene (2)
- Quantification (2)
- Raman (2)
- Reference material (2)
- Reference materials (2)
- Silver nanoparticles (2)
- Single cell analysis (2)
- Spectrometry (2)
- Sulfamethoxazole (2)
- Sulfur (2)
- Wastewater (2)
- X-ray diffraction (2)
- XPS (2)
- Zinc (2)
- 2D chromatography (1)
- 3R concept (1)
- A4F (1)
- AAS (1)
- ABC (1)
- AFM (1)
- AP-MALDI (1)
- Abel inversion (1)
- Ablation (1)
- Absolute quantum yield (1)
- Absorption spectrometry (1)
- Acceptance area (1)
- Accuracy (1)
- Acoustic levition (1)
- Aerosols (1)
- Ag nanoparticles (1)
- Aggregation (1)
- Air (1)
- Airbrush (1)
- AlCl (1)
- Algorithms (1)
- Aluminium (1)
- Ambient desorption/ionization mass spectrometry (1)
- Ambient pressure laser ionization (1)
- Anemia (1)
- Animal welfare (1)
- Anthropogenic markers (1)
- Array (1)
- Arrhenius model (1)
- Asymmetric flow filed-flow fractionation (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Asymmetrical flow field-flow fractionation (AF4) (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Automated Data Evaluation (1)
- BERM (1)
- Barium ion emission (1)
- Berlin tap water (1)
- Bioavailability (1)
- Bioimaging (1)
- Bioimaging by LA-ICP-MS (1)
- Biological sewage plants (1)
- Biosensor development (1)
- Biotransformation (1)
- Bisphenol A degradation (1)
- Boron (1)
- Boron isotopes (1)
- Boron monohydride (1)
- Brunauer-Emmett-Teller (1)
- Caesium (1)
- Calcium monofluoride (1)
- Calibrated SEM/EDS (1)
- Calibration-free analysis (1)
- Calibration-free laser-induced breakdown spectroscopy (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Carbamazepin (1)
- Carbon dioxide (1)
- Carboxyl group (1)
- Cast iron (1)
- Catalytic wet peroxide oxidation (1)
- Cattle (1)
- Cement paste (1)
- Certified reference materials (1)
- Cetirizin (1)
- Cetirizine (1)
- Characterization of catalysts (1)
- Charge coupled devices (1)
- Chelex-100 (1)
- Chloride attack (1)
- Chlorides (1)
- Chlorine (1)
- Click Chemistry (1)
- Cluster (1)
- Cocaine (1)
- Colloidal suspension (1)
- Colloidal suspensions (1)
- Combustion gases (1)
- Comparison (1)
- Complexing agents (1)
- Coproantibodies (1)
- Correlation analysis (1)
- Coumaric acid (1)
- Crosslinking (1)
- Cytochrome P450 CYP1A2 (1)
- DCTB (1)
- DP laser induced plasma (1)
- Dairy cows (1)
- Damaging mechanism (1)
- Detection limits (1)
- Detector efficiency (1)
- Detektorvergleich (1)
- Diatomic molecule (1)
- Dielectric barrier discharge (1)
- Dissolution (1)
- Double-pulse LIBS (1)
- Dried droplet (1)
- Droplet (1)
- Droplets (1)
- Drugs on bills (1)
- Dual mode (1)
- Durability (1)
- Dyes (1)
- EC-LC-MS (1)
- EC/LC/MS (1)
- EC/MS (1)
- EDS-TM001 (1)
- EDX (1)
- EDX-SEM (1)
- EDXD (1)
- ERM (1)
- ESEM (1)
- ESR (1)
- Echelle (1)
- Electrochemistry (1)
- Element determination (1)
- Elemental analytical mehtods (1)
- Elemental tagging (1)
- Emission/fluorescence ratio (1)
- Encapsulation (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Energy transfer (1)
- Environment (1)
- Environmental monitoring (1)
- Environmental quality standard (EQS) (1)
- Enzyme-Linked Immunosorbent Assay (1)
- Enzyme-linked immunosorbent assay (1)
- Equivalence (1)
- Euro banknotes (1)
- Evaporation of droplets (1)
- Explosive (1)
- FT-Raman spectroscopy (1)
- FWHM (1)
- Fe nanoparticles metabolism (1)
- Fe-based highly active ionic liquids (1)
- Feces (1)
- Feed (1)
- Feeding regime (1)
- Fenton oxidation (1)
- Ferrocene (1)
- Field flow fractionation (1)
- Fields (1)
- Firework display (1)
- Five iron oxalate core–shell magnetite nanoparticles catalysts are evaluated as magnetic heterogeneous (1)
- Fixed-points (1)
- Focal distance (1)
- Foodstuffs (1)
- Fourier transform spectroscopy (1)
- Fungicide (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- Gadolinium-uptake (1)
- Gas-phase NMR spectroscopy (1)
- Gd based contrast agents (1)
- Geochemical analysis (1)
- Germanium sulfide (1)
- Glow discharge (1)
- Glycan microarray (1)
- Gold (1)
- Gold-Nanopartikel (1)
- Grafting (1)
- Grimm type glow discharge (1)
- Guest complexe (1)
- HDEHP (1)
- HILIC (1)
- HILIC chromatography (1)
- HRMS (1)
- Hapten immunoassay (1)
- Heavy crude oil (1)
- High performance liquid chromatography (1)
- High resolution glow discharge mass (1)
- High-resolution continuum source absorption spectrometry (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hollow cathode (1)
- Homogenität (1)
- Hormone (1)
- Human serum (1)
- Humic acid (1)
- Humic colloids (1)
- Hydrodynamic chromatography (HDC) (1)
- Hyphenated technique (1)
- ICCD CCD (1)
- IDMS (1)
- IR-MALDI (1)
- ITS-90 (1)
- IgG (1)
- Imaging MS (1)
- Immunization monitoring (1)
- Immunoassays (1)
- Impurities (1)
- In situ (1)
- In situ analysis (1)
- In-situ-Analyse (1)
- Integrating sphere (1)
- Interferometry (1)
- Internal standard (1)
- Inverse Abel Transform (1)
- Ion exchanged soda lime silicate glass (1)
- Ion mobility spectrometry (1)
- Ionic liquid (1)
- Ionic liquids (1)
- Ionmobility spectrometry (1)
- Iposomes (1)
- Iron nanoparticles (1)
- Iron ore (1)
- Iron-sucrose nanoparticles (1)
- Isotope (1)
- Isotope dilution mass spectrometry (1)
- Isotope ratios (1)
- Key comparison (1)
- Kolloidale Suspensionen (1)
- Konduktometrische Titration (1)
- Kramers background (1)
- Kreuzreaktivität (1)
- Kupfer (1)
- LA-ICP-MS based immunoassays (1)
- LA-ICP-OES (1)
- LC-MS (1)
- LCMSMS (1)
- Langmuir isotherm (1)
- Laser Induced Breakdown Spectroscopy (1)
- Laser desorption ionization (1)
- Laser induced breakdown spectroscopy (LIBS) (1)
- Laser induced fluorescence (1)
- Laser-spark (1)
- Laserablation (1)
- Light diffraction (1)
- Linear correlation (1)
- Liquid chromatography at critical conditions (1)
- Liquid matrix (1)
- Liver function tests (1)
- Luminescence (1)
- MALDI Massenspektrometrie (1)
- MALDI TOF mass spectrometry (1)
- MALDI mass spectrometry (1)
- MRI contrast agent (1)
- Machine learning (1)
- Magnetic coreshell nanocatalysts (1)
- Magnetic nanocatalyst (1)
- Magnetic resonance imaging (1)
- Magnetische Nanopartikel (1)
- Magnetpartikel (1)
- Manipulation (1)
- Mass spectrometry imaging (1)
- Material identification (1)
- Matrix (1)
- Matrix calculation (1)
- Matrix evaporation (1)
- Matrix influence (1)
- Matrix segregation (1)
- Matrix separation (1)
- Matrix-method (1)
- Matrixeffekte (1)
- Measuremment uncertainty (1)
- Mechanochemistry (1)
- Mega-dalton (1)
- Memory effect (1)
- Metal (1)
- Metal organic compounds (1)
- Metals (1)
- Metrology (1)
- Metrology in chemistry (1)
- Micro spot (1)
- Micro-hardness (1)
- Microdroplet generator (1)
- Microemulsion (1)
- Microparticles (1)
- Microphony (1)
- Microstructure (1)
- Mikropartikel (1)
- Mitigation (1)
- Modeling (1)
- Modelling (1)
- Modern art (1)
- Molecular absorption (1)
- Molecular masses (1)
- Molten glass (1)
- Monte Carlo simulation (1)
- Multi-element screening (1)
- Multiphoton fabrication (1)
- Multiplexing (1)
- Multivariate classification (1)
- Nano (1)
- Nano-carrier (1)
- Nanocatalysts (1)
- Nanocrystals (1)
- Nanomaterials (1)
- Nanon (1)
- Nanoparticle characterization (1)
- Nanoparticles with same nominal diameter (1)
- Nifedipine (1)
- Nile red (1)
- Noncontact measurement technique (1)
- Noncontact ultrasonic transportation (1)
- Oberflächenfunktionalisierung (1)
- Oberflächenwasser (1)
- Online NMR Spectroscopy (1)
- Optically saturated fluorescence (1)
- Organic peroxides (1)
- Organophosphate agrochemicals (1)
- Orthogonal double pulse plasma (1)
- Oxidative metabolism (1)
- Parallel computing (1)
- Parallelising mode (1)
- Particle size range (1)
- Particulate matter (1)
- Peptide library (1)
- Pesticide (1)
- Pharmaceuticals (1)
- Photo-Fenton oxidation (1)
- Photoacoustic spectroscopy (1)
- Photoluminescence (1)
- Photon generation yield (1)
- Pigments (1)
- Pin sample (1)
- Plants (1)
- Plasma diagnostics (1)
- Plasma spectrum analysis (1)
- Plasma temperature (1)
- Plume (1)
- Pollen germination (1)
- Pollen tube (1)
- Polycapillary X-ray optics (1)
- Polymerisation (1)
- Polymers (1)
- Polystyrol (1)
- Polyurethane (1)
- Portland cement (1)
- Post-breakdown laser induced plasma (1)
- Precision (1)
- Primary reference gas mixtures (1)
- Primary standards (1)
- Principal component analysis (1)
- Process Analytical Technology (1)
- Public funding (1)
- Pulse duration (1)
- Pure copper (1)
- Purification (1)
- Purity (1)
- Pyrotechnic articles (1)
- QuEChERS (1)
- Quantitative NMR spectroscopy (1)
- Quantitative analysis (1)
- Quantum dots (1)
- Quantum yield (1)
- Quaternary oxides (1)
- RESS (1)
- Radon transform (1)
- Radon transform technique (1)
- Radon transform tomography of SP (1)
- Raman microscopy (1)
- Raman microspectroscopy (1)
- Reabsorption (1)
- Reaction Monitoring (1)
- Reactive azo dye degradation (1)
- Reconstructed ion chromatograms (1)
- Recycling (1)
- Reference (1)
- Reference measurements (1)
- Reference value (1)
- Reference value uncertainty (1)
- Reference-free XRF (1)
- Removal (1)
- Renewable copolymers (1)
- Reorganization (1)
- Rhodamine 6G (1)
- RoHS (1)
- Röntgenbeugung (1)
- SDHI-fungicide (1)
- SEC (1)
- SEM/EDS (1)
- SERS (1)
- SF-ICP-MS (1)
- SI (1)
- Saliva (1)
- Sample dissolution (1)
- Sample enrichment (1)
- Sample loss (1)
- Sample preparation (1)
- Scattering (1)
- Sector field mass spectrometry (1)
- Semi-lens (1)
- Sensitivity (1)
- Sensitized magnetic nanocatalysts (1)
- Serum (1)
- Shelf life (1)
- Side-window X-ray tube (1)
- Silicon (1)
- Silver (1)
- Simulation (1)
- Single Cell Analysis (1)
- Singlet oxygen (1)
- Singulettsauerstoff (1)
- Small objects (1)
- Sol-gel processes (1)
- Solar grade silicon (1)
- Solid phase extraction (1)
- Solvatochromism (1)
- Sonic spray (1)
- Sonic spray ionization (1)
- Sonochemical synthesis (1)
- SpICP-MS (1)
- Spark-OES (1)
- Spatial heterodyne spectroscopy (1)
- Spatial investigations (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrometer (1)
- Spectrometer efficiency (1)
- Sporopollenin (1)
- Stability (1)
- Stable isotope (1)
- Standard-less analysis (1)
- Steel (1)
- Steel slag (1)
- Structure (1)
- Sulfate attack (1)
- Supercritical fluids (1)
- Surface coating (1)
- Surface-enhanced Raman scattering (1)
- Suspended particulate matter (1)
- Swelling (1)
- Synchrotron-radiation (1)
- Synthetic organic pigments (1)
- TATP (1)
- TEM (1)
- Terrorism (1)
- Thermal degradation (1)
- Thiol-ene click chemistry (1)
- Threshold values (1)
- ToF-SIMS (1)
- Toxicology (1)
- Trace elements (1)
- Transformation product (1)
- Transformation products (1)
- Transmission (1)
- Triacetone triperoxide (1)
- Tributyltin (TBT) (1)
- Two-dimensional off-line coupling (1)
- UPLC (1)
- UV degradation (1)
- Ultra high purity (1)
- Ultraschallfalle (1)
- Ultrasonic acoustic resonator (1)
- Ultrasonic trap (1)
- Urine (1)
- Vacuum distillation (1)
- Validation (1)
- Validierung (1)
- Wastewater marker (1)
- Water treatment (1)
- X-ray tube spectra (1)
- X-ray tube spectrum (1)
- X-ray-scattering (1)
- XRD (1)
- Xerogel (1)
- ZRM (1)
- Zementhydratation (1)
- Zeta-Potential (1)
- Zirconium (1)
- glass fibre paper (1)
- ion optics (1)
- muXRF (1)
- pH-Abhängigkeit (1)
- sensing (1)
- spray (1)
- surface enhanced Raman scattering (1)
- µSpot (1)
- ß-amino-cyclodextrin (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (30)
- P Präsident (24)
- P.0 Präsident und andere (24)
- 1.1 Anorganische Spurenanalytik (15)
- 6 Materialchemie (10)
- 1.6 Anorganische Referenzmaterialien (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (6)
- 6.3 Strukturanalytik (6)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- 1.8 Umweltanalytik (4)
Particle-based assays are becoming versatile analytical tools due to their cost-effectiveness, speed, straightforward and diverse functionalization chemistries, especially when polystyrene particles are used. The introduction of functional groups (–COOH, –NH2, etc.) to the surface of such polystyrene particles promotes their application in bioanalytics. However, the traditional method to determine the amount of surface carboxylate groups is conductivity titration, which is usually time- and resources-consuming and discontinuous. Here, we synthesized polystyrene microparticles with different contents of carboxylate groups, and then investigated a simpler and potentially continuous approach to determine the amount of surface carboxylate groups by Zeta potential measurements. The results were compared to the traditional titration method and to actual coupling efficiencies of the functionalized particles with a model oligonucleotide probe as determined by flow cytometry. All quantification methods revealed good agreement.
Two sets of polystyrene nanoparticles (PSNPs) with comparable core sizes but different carboxyl group densities were made and separated using asymmetric flow field flow fractionation (AF4), capillary electrophoresis (CE), and the off-line hyphenation of both methods. Our results revealed the significant potential of two-dimensional off-line AF4-CE hyphenation to improve the separation and demonstrated for the first time, the applicability of CE to determine the functional group density of nanoparticles (NPs). Compared to the result acquired with conductometric titration, the result obtained with synthesized 100 nm sized PSNPs revealed only a slight deviation of 1.7%. Commercial 100 nm sized PSNPs yielded a deviation of 4.6 %. For 60 nm sized PSNPs, a larger deviation of 10.6 % between both methods was observed, which is attributed to the lower separation resolution.
The successful off-line coupling of asymmetrical flow field flow fractionation (AF4) and capillary electrophoresis (CE) for separation of nanoparticles (NPs) with different surface coatings was shown. We could successfully demonstrate that, in a certain NP size range, hyphenation of both techniques significantly improved the separation of differently coated NPs. Three mixtures of polystyrene nanoparticles (PS-NPs) with comparable core sizes but different coatings (no coating/carboxyl-coated) were studied. Separation in either method resulted in non-baseline resolved or non-separated peaks. In contrast, two-dimensional off-line coupling of AF4 and CE resulted in clearly separated regions in their 2 D plots in case of 20 and 50 nm particle mixtures, whereas the 100 nm NP mixture could not be separated at all. Various factors affecting the separation like hydrodynamic diameter or SDS concentration were discussed.
To establish the methodical basis for the development and certification of fluorescence quantum yield standards, we determined the fluorescence quantum yield Φf of rhodamine 6G (R6G) with two absolute methods with complementary measurement principles, here optical spectroscopy using an integrating sphere setup and pulsed laser photoacoustic spectroscopy (PAS). For the assessment of aggregation- and reabsorption-induced distortions of measured fluorescence quantum yields and procedures for the reliable consideration of such effects, this systematic comparison was performed in ethanol and in water employing different concentrations of R6G. In addition, the relative and absolute fluorescence quantum yields of these solutions were obtained with a calibrated spectrofluorometer and a commercialized integrating sphere setup. Based upon this systematic comparison, experimental advantages and systematic sources of variation were identified for both methods.
During the mineralisation of metal carbonates MCO3 (M = Ca, Sr, Ba, Mn, Cd, Pb) liquid-like amorphous intermediates emerge. These intermediates that form via a liquid/liquid phase separation behave like a classical emulsion and are stabilized electrostatically. The occurrence of these intermediates is attributed to the formation of highly hydrated networks whose stability is mainly based on weak interactions and the variability of the metal-containing pre-critical clusters. Their existence and compositional freedom are evidenced by electrospray ionization mass spectrometry (ESI-MS). Liquid intermediates in non-classical crystallisation pathways seem to be more common than assumed.
An alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry. For isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions, ranging from 0.06 to 0.99 mol mol–1, previously determined by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS). The calibration ML model was validated with two certified reference materials (LSVEC and IRMM-016). The procedure was applied toward the isotope amount ratio determination of a set of stock chemicals (Li2CO3, LiNO3, LiCl, and LiOH) and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. The results of these determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9 to 6.2‰. This precision was sufficient to resolve naturally occurring variations, as demonstrated for samples ranging from approximately −3 to +15‰. To assess its suitability to technical applications, the NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification. The results obtained were metrologically compatible with each other.
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry.
Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated.
Matrix-assisted laser desorption/ionization-timeof-flight (MALDI-TOF) imaging of polystyrenes with various molecular masses was applied to study spatial molecular mass distribution of polymers in sample spots prepared by the 'dried droplet' method. When different solvents and target surfaces were examined, a segregation of single homologous polymers was observed depending upon the evaporation rate of the solvent. For the observed Patterns left by the evaporating droplet, a hypothesis is offered taking into account different hydrodynamic interactions and diffusion.
The results illustrate that spot preparation using the conventionally 'dried droplet' method is prone to artifacts and should be avoided for reliable and reproducible MALDI mass spectrometry experiments with regards to the Determination of molecular masses and mass distributions.