Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (179) (entfernen)
Schlagworte
- ICP-MS (12)
- LIBS (12)
- ELISA (8)
- LC-MS/MS (8)
- Laser ablation (8)
- Speciation (7)
- Acoustic levitation (6)
- Laser induced plasma (5)
- Laser-induced breakdown spectroscopy (5)
- Nanoparticles (5)
- Traceability (5)
- Caffeine (4)
- Calibration (4)
- Copper (4)
- Fluorescence (4)
- Immunoassay (4)
- Ionization (4)
- LA-ICP-MS (4)
- SEM (4)
- Water (4)
- XRF (4)
- Ambient mass spectrometry (3)
- Antibody (3)
- Bisphenol A (3)
- Carbamazepine (3)
- Characterization (3)
- EDS (3)
- Graphite furnace (3)
- HR-CS-MAS (3)
- High resolution (3)
- In-situ (3)
- Inductively coupled plasma mass spectrometry (ICP-MS) (3)
- Isotope dilution analysis (3)
- Laser-induced plasma (3)
- Levitated droplets (3)
- MALDI (3)
- Photodegradation (3)
- Pollen (3)
- Polymer (3)
- Raman spectroscopy (3)
- Single particle ICP-MS (3)
- Surface water (3)
- SyXRD (3)
- Synchrotron radiation (3)
- Uncertainty (3)
- X-Ray diffraction (3)
- Abwasser (2)
- Bioconjugation (2)
- Cell (2)
- Cells (2)
- Cement hydration (2)
- Chemical analysis (2)
- Chemometrics (2)
- Crystallization (2)
- DPSS laser (2)
- ESI-TOF-MS (2)
- Electrochemical oxidation (2)
- Emission spectroscopy (2)
- Fenton (2)
- Gadolinium (2)
- Gadolinium-based contrast agents (2)
- HPLC (2)
- HPLC-ICP-MS (2)
- High repetition rate (2)
- Hydrophilic interaction chromatography (HILIC) (2)
- Imaging (2)
- In vitro (2)
- Isotope dilution (2)
- Katalysator (2)
- Lithium (2)
- Magnesium (2)
- Mass spectrometry (2)
- Metabolism (2)
- Micropollutants (2)
- Milk (2)
- Multivariate statistics (2)
- NEXAFS (2)
- Nanoparticle (2)
- Optical emission spectroscopy (2)
- Photooxidation (2)
- Plasma tomography (2)
- Polymorphism (2)
- Polystyrene (2)
- Quantification (2)
- Raman (2)
- Reference material (2)
- Reference materials (2)
- Silver nanoparticles (2)
- Single cell analysis (2)
- Spectrometry (2)
- Sulfamethoxazole (2)
- Sulfur (2)
- Wastewater (2)
- X-ray diffraction (2)
- XPS (2)
- Zinc (2)
- 2D chromatography (1)
- 3R concept (1)
- A4F (1)
- AAS (1)
- ABC (1)
- AFM (1)
- AP-MALDI (1)
- Abel inversion (1)
- Ablation (1)
- Absolute quantum yield (1)
- Absorption spectrometry (1)
- Acceptance area (1)
- Accuracy (1)
- Acoustic levition (1)
- Aerosols (1)
- Ag nanoparticles (1)
- Aggregation (1)
- Air (1)
- Airbrush (1)
- AlCl (1)
- Algorithms (1)
- Aluminium (1)
- Ambient desorption/ionization mass spectrometry (1)
- Ambient pressure laser ionization (1)
- Anemia (1)
- Animal welfare (1)
- Anthropogenic markers (1)
- Array (1)
- Arrhenius model (1)
- Asymmetric flow filed-flow fractionation (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Asymmetrical flow field-flow fractionation (AF4) (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Automated Data Evaluation (1)
- BERM (1)
- Barium ion emission (1)
- Berlin tap water (1)
- Bioavailability (1)
- Bioimaging (1)
- Bioimaging by LA-ICP-MS (1)
- Biological sewage plants (1)
- Biosensor development (1)
- Biotransformation (1)
- Bisphenol A degradation (1)
- Boron (1)
- Boron isotopes (1)
- Boron monohydride (1)
- Brunauer-Emmett-Teller (1)
- Caesium (1)
- Calcium monofluoride (1)
- Calibrated SEM/EDS (1)
- Calibration-free analysis (1)
- Calibration-free laser-induced breakdown spectroscopy (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Carbamazepin (1)
- Carbon dioxide (1)
- Carboxyl group (1)
- Cast iron (1)
- Catalytic wet peroxide oxidation (1)
- Cattle (1)
- Cement paste (1)
- Certified reference materials (1)
- Cetirizin (1)
- Cetirizine (1)
- Characterization of catalysts (1)
- Charge coupled devices (1)
- Chelex-100 (1)
- Chloride attack (1)
- Chlorides (1)
- Chlorine (1)
- Click Chemistry (1)
- Cluster (1)
- Cocaine (1)
- Colloidal suspension (1)
- Colloidal suspensions (1)
- Combustion gases (1)
- Comparison (1)
- Complexing agents (1)
- Coproantibodies (1)
- Correlation analysis (1)
- Coumaric acid (1)
- Crosslinking (1)
- Cytochrome P450 CYP1A2 (1)
- DCTB (1)
- DP laser induced plasma (1)
- Dairy cows (1)
- Damaging mechanism (1)
- Detection limits (1)
- Detector efficiency (1)
- Detektorvergleich (1)
- Diatomic molecule (1)
- Dielectric barrier discharge (1)
- Dissolution (1)
- Double-pulse LIBS (1)
- Dried droplet (1)
- Droplet (1)
- Droplets (1)
- Drugs on bills (1)
- Dual mode (1)
- Durability (1)
- Dyes (1)
- EC-LC-MS (1)
- EC/LC/MS (1)
- EC/MS (1)
- EDS-TM001 (1)
- EDX (1)
- EDX-SEM (1)
- EDXD (1)
- ERM (1)
- ESEM (1)
- ESR (1)
- Echelle (1)
- Electrochemistry (1)
- Element determination (1)
- Elemental analytical mehtods (1)
- Elemental tagging (1)
- Emission/fluorescence ratio (1)
- Encapsulation (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Energy transfer (1)
- Environment (1)
- Environmental monitoring (1)
- Environmental quality standard (EQS) (1)
- Enzyme-Linked Immunosorbent Assay (1)
- Enzyme-linked immunosorbent assay (1)
- Equivalence (1)
- Euro banknotes (1)
- Evaporation of droplets (1)
- Explosive (1)
- FT-Raman spectroscopy (1)
- FWHM (1)
- Fe nanoparticles metabolism (1)
- Fe-based highly active ionic liquids (1)
- Feces (1)
- Feed (1)
- Feeding regime (1)
- Fenton oxidation (1)
- Ferrocene (1)
- Field flow fractionation (1)
- Fields (1)
- Firework display (1)
- Five iron oxalate core–shell magnetite nanoparticles catalysts are evaluated as magnetic heterogeneous (1)
- Fixed-points (1)
- Focal distance (1)
- Foodstuffs (1)
- Fourier transform spectroscopy (1)
- Fungicide (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- Gadolinium-uptake (1)
- Gas-phase NMR spectroscopy (1)
- Gd based contrast agents (1)
- Geochemical analysis (1)
- Germanium sulfide (1)
- Glow discharge (1)
- Glycan microarray (1)
- Gold (1)
- Gold-Nanopartikel (1)
- Grafting (1)
- Grimm type glow discharge (1)
- Guest complexe (1)
- HDEHP (1)
- HILIC (1)
- HILIC chromatography (1)
- HRMS (1)
- Hapten immunoassay (1)
- Heavy crude oil (1)
- High performance liquid chromatography (1)
- High resolution glow discharge mass (1)
- High-resolution continuum source absorption spectrometry (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hollow cathode (1)
- Homogenität (1)
- Hormone (1)
- Human serum (1)
- Humic acid (1)
- Humic colloids (1)
- Hydrodynamic chromatography (HDC) (1)
- Hyphenated technique (1)
- ICCD CCD (1)
- IDMS (1)
- IR-MALDI (1)
- ITS-90 (1)
- IgG (1)
- Imaging MS (1)
- Immunization monitoring (1)
- Immunoassays (1)
- Impurities (1)
- In situ (1)
- In situ analysis (1)
- In-situ-Analyse (1)
- Integrating sphere (1)
- Interferometry (1)
- Internal standard (1)
- Inverse Abel Transform (1)
- Ion exchanged soda lime silicate glass (1)
- Ion mobility spectrometry (1)
- Ionic liquid (1)
- Ionic liquids (1)
- Ionmobility spectrometry (1)
- Iposomes (1)
- Iron nanoparticles (1)
- Iron ore (1)
- Iron-sucrose nanoparticles (1)
- Isotope (1)
- Isotope dilution mass spectrometry (1)
- Isotope ratios (1)
- Key comparison (1)
- Kolloidale Suspensionen (1)
- Konduktometrische Titration (1)
- Kramers background (1)
- Kreuzreaktivität (1)
- Kupfer (1)
- LA-ICP-MS based immunoassays (1)
- LA-ICP-OES (1)
- LC-MS (1)
- LCMSMS (1)
- Langmuir isotherm (1)
- Laser Induced Breakdown Spectroscopy (1)
- Laser desorption ionization (1)
- Laser induced breakdown spectroscopy (LIBS) (1)
- Laser induced fluorescence (1)
- Laser-spark (1)
- Laserablation (1)
- Light diffraction (1)
- Linear correlation (1)
- Liquid chromatography at critical conditions (1)
- Liquid matrix (1)
- Liver function tests (1)
- Luminescence (1)
- MALDI Massenspektrometrie (1)
- MALDI TOF mass spectrometry (1)
- MALDI mass spectrometry (1)
- MRI contrast agent (1)
- Machine learning (1)
- Magnetic coreshell nanocatalysts (1)
- Magnetic nanocatalyst (1)
- Magnetic resonance imaging (1)
- Magnetische Nanopartikel (1)
- Magnetpartikel (1)
- Manipulation (1)
- Mass spectrometry imaging (1)
- Material identification (1)
- Matrix (1)
- Matrix calculation (1)
- Matrix evaporation (1)
- Matrix influence (1)
- Matrix segregation (1)
- Matrix separation (1)
- Matrix-method (1)
- Matrixeffekte (1)
- Measuremment uncertainty (1)
- Mechanochemistry (1)
- Mega-dalton (1)
- Memory effect (1)
- Metal (1)
- Metal organic compounds (1)
- Metals (1)
- Metrology (1)
- Metrology in chemistry (1)
- Micro spot (1)
- Micro-hardness (1)
- Microdroplet generator (1)
- Microemulsion (1)
- Microparticles (1)
- Microphony (1)
- Microstructure (1)
- Mikropartikel (1)
- Mitigation (1)
- Modeling (1)
- Modelling (1)
- Modern art (1)
- Molecular absorption (1)
- Molecular masses (1)
- Molten glass (1)
- Monte Carlo simulation (1)
- Multi-element screening (1)
- Multiphoton fabrication (1)
- Multiplexing (1)
- Multivariate classification (1)
- Nano (1)
- Nano-carrier (1)
- Nanocatalysts (1)
- Nanocrystals (1)
- Nanomaterials (1)
- Nanon (1)
- Nanoparticle characterization (1)
- Nanoparticles with same nominal diameter (1)
- Nifedipine (1)
- Nile red (1)
- Noncontact measurement technique (1)
- Noncontact ultrasonic transportation (1)
- Oberflächenfunktionalisierung (1)
- Oberflächenwasser (1)
- Online NMR Spectroscopy (1)
- Optically saturated fluorescence (1)
- Organic peroxides (1)
- Organophosphate agrochemicals (1)
- Orthogonal double pulse plasma (1)
- Oxidative metabolism (1)
- Parallel computing (1)
- Parallelising mode (1)
- Particle size range (1)
- Particulate matter (1)
- Peptide library (1)
- Pesticide (1)
- Pharmaceuticals (1)
- Photo-Fenton oxidation (1)
- Photoacoustic spectroscopy (1)
- Photoluminescence (1)
- Photon generation yield (1)
- Pigments (1)
- Pin sample (1)
- Plants (1)
- Plasma diagnostics (1)
- Plasma spectrum analysis (1)
- Plasma temperature (1)
- Plume (1)
- Pollen germination (1)
- Pollen tube (1)
- Polycapillary X-ray optics (1)
- Polymerisation (1)
- Polymers (1)
- Polystyrol (1)
- Polyurethane (1)
- Portland cement (1)
- Post-breakdown laser induced plasma (1)
- Precision (1)
- Primary reference gas mixtures (1)
- Primary standards (1)
- Principal component analysis (1)
- Process Analytical Technology (1)
- Public funding (1)
- Pulse duration (1)
- Pure copper (1)
- Purification (1)
- Purity (1)
- Pyrotechnic articles (1)
- QuEChERS (1)
- Quantitative NMR spectroscopy (1)
- Quantitative analysis (1)
- Quantum dots (1)
- Quantum yield (1)
- Quaternary oxides (1)
- RESS (1)
- Radon transform (1)
- Radon transform technique (1)
- Radon transform tomography of SP (1)
- Raman microscopy (1)
- Raman microspectroscopy (1)
- Reabsorption (1)
- Reaction Monitoring (1)
- Reactive azo dye degradation (1)
- Reconstructed ion chromatograms (1)
- Recycling (1)
- Reference (1)
- Reference measurements (1)
- Reference value (1)
- Reference value uncertainty (1)
- Reference-free XRF (1)
- Removal (1)
- Renewable copolymers (1)
- Reorganization (1)
- Rhodamine 6G (1)
- RoHS (1)
- Röntgenbeugung (1)
- SDHI-fungicide (1)
- SEC (1)
- SEM/EDS (1)
- SERS (1)
- SF-ICP-MS (1)
- SI (1)
- Saliva (1)
- Sample dissolution (1)
- Sample enrichment (1)
- Sample loss (1)
- Sample preparation (1)
- Scattering (1)
- Sector field mass spectrometry (1)
- Semi-lens (1)
- Sensitivity (1)
- Sensitized magnetic nanocatalysts (1)
- Serum (1)
- Shelf life (1)
- Side-window X-ray tube (1)
- Silicon (1)
- Silver (1)
- Simulation (1)
- Single Cell Analysis (1)
- Singlet oxygen (1)
- Singulettsauerstoff (1)
- Small objects (1)
- Sol-gel processes (1)
- Solar grade silicon (1)
- Solid phase extraction (1)
- Solvatochromism (1)
- Sonic spray (1)
- Sonic spray ionization (1)
- Sonochemical synthesis (1)
- SpICP-MS (1)
- Spark-OES (1)
- Spatial heterodyne spectroscopy (1)
- Spatial investigations (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrometer (1)
- Spectrometer efficiency (1)
- Sporopollenin (1)
- Stability (1)
- Stable isotope (1)
- Standard-less analysis (1)
- Steel (1)
- Steel slag (1)
- Structure (1)
- Sulfate attack (1)
- Supercritical fluids (1)
- Surface coating (1)
- Surface-enhanced Raman scattering (1)
- Suspended particulate matter (1)
- Swelling (1)
- Synchrotron-radiation (1)
- Synthetic organic pigments (1)
- TATP (1)
- TEM (1)
- Terrorism (1)
- Thermal degradation (1)
- Thiol-ene click chemistry (1)
- Threshold values (1)
- ToF-SIMS (1)
- Toxicology (1)
- Trace elements (1)
- Transformation product (1)
- Transformation products (1)
- Transmission (1)
- Triacetone triperoxide (1)
- Tributyltin (TBT) (1)
- Two-dimensional off-line coupling (1)
- UPLC (1)
- UV degradation (1)
- Ultra high purity (1)
- Ultraschallfalle (1)
- Ultrasonic acoustic resonator (1)
- Ultrasonic trap (1)
- Urine (1)
- Vacuum distillation (1)
- Validation (1)
- Validierung (1)
- Wastewater marker (1)
- Water treatment (1)
- X-ray tube spectra (1)
- X-ray tube spectrum (1)
- X-ray-scattering (1)
- XRD (1)
- Xerogel (1)
- ZRM (1)
- Zementhydratation (1)
- Zeta-Potential (1)
- Zirconium (1)
- glass fibre paper (1)
- ion optics (1)
- muXRF (1)
- pH-Abhängigkeit (1)
- sensing (1)
- spray (1)
- surface enhanced Raman scattering (1)
- µSpot (1)
- ß-amino-cyclodextrin (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (30)
- P Präsident (25)
- P.0 Präsident und andere (25)
- 1.1 Anorganische Spurenanalytik (15)
- 6 Materialchemie (10)
- 1.6 Anorganische Referenzmaterialien (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (6)
- 6.3 Strukturanalytik (6)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- 1.8 Umweltanalytik (4)
The stable carbon and nitrogen isotopic composition of urine and milk samples from cattle under different feeding regimes were analysed over a period of six months. The isotope ratios were measured with isotope ratio mass spectrometry (IRMS). The δ13C values of milk and urine were dependent on different feeding regimes based on C3 or C4 plants. The δ13C values are more negative under grass feeding than under maize feeding. The δ13C values of milk are more negative compared to urine and independent of the feeding regime. Under grass feeding the analysed milk and urine samples are enriched in 13C relative to the feed, whereas under maize feeding the 13C/12C ratio of urine is in the same range and milk is depleted in 13C relative to the diet. The difference between the 15N/14N ratios for the two feeding regimes is less pronounced than the 13C/12C ratios. The δ15N values in urine require more time to reach the new equilibrium, whereas the milk samples show no significant differences between the two feeding regimes.
For the investigation of small sample volumes, the use of an acoustic levitator was tested as a `sample holder' for hovering droplets in a synchrotron beam. It might be advantageous to use levitated droplets instead of samples confined in solid holders, especially for the study of crystallization processes where the influence of containing walls has to be minimized. In a first experiment, the crystallization of sodium chloride in a small droplet of aqueous solution has been followed with a time resolution of 30 s. The collected diffraction peaks are compared with data in the ICSD database.
To establish the methodical basis for the development and certification of fluorescence quantum yield standards, we determined the fluorescence quantum yield Φf of rhodamine 6G (R6G) with two absolute methods with complementary measurement principles, here optical spectroscopy using an integrating sphere setup and pulsed laser photoacoustic spectroscopy (PAS). For the assessment of aggregation- and reabsorption-induced distortions of measured fluorescence quantum yields and procedures for the reliable consideration of such effects, this systematic comparison was performed in ethanol and in water employing different concentrations of R6G. In addition, the relative and absolute fluorescence quantum yields of these solutions were obtained with a calibrated spectrofluorometer and a commercialized integrating sphere setup. Based upon this systematic comparison, experimental advantages and systematic sources of variation were identified for both methods.
The formation and growth of hydroxylamine reduced silver nanoparticles were investigated by simultaneous Raman and UV/Vis spectroscopy coupled to an acoustic levitator as a sample holder. Based on the UV/Vis spectra, a two step particle formation mechanism with fast initial formation and adjacent coalescence can be proposed for the reduction of silver nitrate with hydroxylamine. The presence of the analyte adenine during particle formation resulted in differences in the adenine SERS signature compared to experiments, where adenine was added after particle synthesis. It was possible to monitor the adenine and sodium chloride induced aggregation of the nanoparticles and its dynamics based on both the extinction spectra and the SERS data. Correlating the information from the extinction spectra with the SERS intensity, the maximum SERS signals were observed at maximum extinction of the aggregated nanoparticle solution at the Raman excitation wavelength.
Hydrophilic interaction chromatography (HILIC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) was optimized for speciation analysis of gadolinium-based contrast agents in environmental samples, in particular surface river waters and plants. Surface water samples from the Teltow channel, near Berlin, were investigated over a distance of 5 km downstream from the influx of a wastewater treatment plant. The total concentration of gadolinium increased significantly from 50 to 990 ngL-1 due to the influx of the contrast agents. After complete mixing with the river water, the concentration remained constant over a distance of at least 4 km. Two main substances [Dotarem® (Gd-DOTA) and Gadovist® (Gd-BT-DO3A)] have been identified in the river water using standards. A gadolinium-based contrast agent, possibly Gd-DOTA (Dotarem®), was also detected in water plant samples taken from the Teltow channel. Therefore, uptake of contrast agents [Gadovist® (Gd-BTDO3A), Magnevist® (Gd-DTPA), Omniscan® (Gd-DTPA-BMA), Dotarem® (Gd-DOTA), and Multihance® (Gd-BOPTA)] by plants was investigated in a model experiment using Lepidium sativum (cress plants). HILICICP-MS was used for identification of different contrast agents, and a first approach for quantification using aqueous standard solutions was tested. For speciation analysis, all investigated contrast agents could be extracted from the plant tissues with a recovery of about 54 % for Multihance® (Gd-BOPTA) up to 106 % for Gadovist® (Gd-BT-DO3A). These experiments demonstrate that all contrast agents investigated are transported from the roots to the leaves where the highest content was measured.
Particle-based assays are becoming versatile analytical tools due to their cost-effectiveness, speed, straightforward and diverse functionalization chemistries, especially when polystyrene particles are used. The introduction of functional groups (–COOH, –NH2, etc.) to the surface of such polystyrene particles promotes their application in bioanalytics. However, the traditional method to determine the amount of surface carboxylate groups is conductivity titration, which is usually time- and resources-consuming and discontinuous. Here, we synthesized polystyrene microparticles with different contents of carboxylate groups, and then investigated a simpler and potentially continuous approach to determine the amount of surface carboxylate groups by Zeta potential measurements. The results were compared to the traditional titration method and to actual coupling efficiencies of the functionalized particles with a model oligonucleotide probe as determined by flow cytometry. All quantification methods revealed good agreement.
Matrix-assisted laser desorption/ionization-timeof-flight (MALDI-TOF) imaging of polystyrenes with various molecular masses was applied to study spatial molecular mass distribution of polymers in sample spots prepared by the 'dried droplet' method. When different solvents and target surfaces were examined, a segregation of single homologous polymers was observed depending upon the evaporation rate of the solvent. For the observed Patterns left by the evaporating droplet, a hypothesis is offered taking into account different hydrodynamic interactions and diffusion.
The results illustrate that spot preparation using the conventionally 'dried droplet' method is prone to artifacts and should be avoided for reliable and reproducible MALDI mass spectrometry experiments with regards to the Determination of molecular masses and mass distributions.
A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling.
A new setup for fast spatially resolved measurements of elemental trace amounts under total reflection conditions using a new colour X-ray camera is described. Samples prepared on conventional total reflection X-ray fluorescence (TXRF) reflectors were measured at BESSY II synchrotron. A spatial resolution of 50 × 50 µm² was obtained, while the required time for the investigation of a 10 × 10 mm² sample is 30 seconds. The set-up is up to 350 times faster than conventional X-ray fluorescence systems for elemental traces. The major components of the X-ray camera are polycapillary optics and a pn-CCD chip with an active area of 13 × 13 mm². This area is divided into 264 × 264 pixels of 48 × 48 µm². A full X-ray spectrum with a resolution of 152 eV @ 5.9 keV and a chip temperature of 246 K is recorded for each pixel. The chip has a read-out rate of 400 Hz.