Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (179)
- Vortrag (46)
- Beitrag zu einem Tagungsband (10)
- Beitrag zu einem Sammelband (3)
- Sonstiges (1)
- Posterpräsentation (1)
Schlagworte
- LIBS (13)
- ICP-MS (12)
- ELISA (8)
- LC-MS/MS (8)
- Laser ablation (8)
- Acoustic levitation (7)
- Speciation (7)
- Traceability (6)
- Calibration (5)
- Characterization (5)
- Laser induced plasma (5)
- Laser-induced breakdown spectroscopy (5)
- Nanoparticles (5)
- Caffeine (4)
- Copper (4)
- Fluorescence (4)
- Immunoassay (4)
- Ionization (4)
- LA-ICP-MS (4)
- SEM (4)
- Wastewater (4)
- Water (4)
- XRF (4)
- Ambient mass spectrometry (3)
- Analytical Sciences (3)
- Antibody (3)
- Bisphenol A (3)
- Bisphenol A degradation (3)
- Carbamazepine (3)
- Chemometrics (3)
- Click Chemistry (3)
- EDS (3)
- Fenton oxidation (3)
- Graphite furnace (3)
- HR-CS-MAS (3)
- High resolution (3)
- In-situ (3)
- Inductively coupled plasma mass spectrometry (ICP-MS) (3)
- Isotope dilution analysis (3)
- Laser-induced plasma (3)
- Levitated droplets (3)
- MALDI (3)
- Nanocatalysts (3)
- Online NMR Spectroscopy (3)
- Photodegradation (3)
- Pollen (3)
- Polymer (3)
- Process Analytical Technology (3)
- Quantification (3)
- Raman spectroscopy (3)
- Single particle ICP-MS (3)
- Surface water (3)
- SyXRD (3)
- Synchrotron radiation (3)
- Uncertainty (3)
- X-Ray diffraction (3)
- Abwasser (2)
- Bioconjugation (2)
- Cell (2)
- Cells (2)
- Cement hydration (2)
- Chemical analysis (2)
- Crystallization (2)
- DPSS laser (2)
- ERM (2)
- ESI-TOF-MS (2)
- Electrochemical oxidation (2)
- Emission spectroscopy (2)
- Fenton (2)
- Firework display (2)
- Gadolinium (2)
- Gadolinium-based contrast agents (2)
- HPLC (2)
- HPLC-ICP-MS (2)
- High repetition rate (2)
- Hydrophilic interaction chromatography (HILIC) (2)
- Imaging (2)
- In vitro (2)
- Indirect Hard Modeling (2)
- Isotope dilution (2)
- Katalysator (2)
- Lithium (2)
- Magnesium (2)
- Mass spectrometry (2)
- Metabolism (2)
- Micropollutants (2)
- Milk (2)
- Multivariate statistics (2)
- NEXAFS (2)
- Nanoparticle (2)
- Optical emission spectroscopy (2)
- Photooxidation (2)
- Plasma tomography (2)
- Polymorphism (2)
- Polystyrene (2)
- Raman (2)
- Reaction Monitoring (2)
- Reference material (2)
- Reference materials (2)
- Silver nanoparticles (2)
- Single cell analysis (2)
- Spectrometry (2)
- Steel slag (2)
- Sulfamethoxazole (2)
- Sulfur (2)
- X-ray diffraction (2)
- XPS (2)
- Zinc (2)
- 2D chromatography (1)
- 3R concept (1)
- A4F (1)
- AAS (1)
- ABC (1)
- AFM (1)
- AP-MALDI (1)
- Abel inversion (1)
- Ablation (1)
- Absolute quantum yield (1)
- Absorption spectrometry (1)
- Acceptance area (1)
- Accuracy (1)
- Acoustic levition (1)
- Aerosols (1)
- Ag nanoparticles (1)
- Aggregation (1)
- Air (1)
- Airbrush (1)
- AlCl (1)
- Algorithms (1)
- Aluminium (1)
- Ambient desorption/ionization mass spectrometry (1)
- Ambient pressure laser ionization (1)
- Analytical method (1)
- Anemia (1)
- Animal welfare (1)
- Anthropogenic markers (1)
- Array (1)
- Arrhenius model (1)
- Asymmetric flow filed-flow fractionation (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Asymmetrical flow field-flow fractionation (AF4) (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Automated Data Evaluation (1)
- BERM (1)
- Barium ion emission (1)
- Berlin tap water (1)
- Bio-Imaging (1)
- Bioavailability (1)
- Bioimaging (1)
- Bioimaging by LA-ICP-MS (1)
- Biological sewage plants (1)
- Biosensor development (1)
- Biotransformation (1)
- Boron (1)
- Boron isotopes (1)
- Boron monohydride (1)
- Brunauer-Emmett-Teller (1)
- CONSENS (1)
- CRM (1)
- Caesium (1)
- Calcium monofluoride (1)
- Calibrated SEM/EDS (1)
- Calibration-free analysis (1)
- Calibration-free laser-induced breakdown spectroscopy (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Carbamazepin (1)
- Carbon dioxide (1)
- Carboxyl group (1)
- Cast iron (1)
- Catalytic wet peroxide oxidation (1)
- Cattle (1)
- Cement paste (1)
- Certified reference materials (1)
- Cetirizin (1)
- Cetirizine (1)
- Characterization of catalysts (1)
- Charge coupled devices (1)
- Chelex-100 (1)
- Chloride attack (1)
- Chlorides (1)
- Chlorine (1)
- Cluster (1)
- Cocaine (1)
- Colloidal suspension (1)
- Colloidal suspensions (1)
- Combustion gases (1)
- Comparability (1)
- Comparison (1)
- Complexing agents (1)
- Coproantibodies (1)
- Correlation analysis (1)
- Coumaric acid (1)
- Crosslinking (1)
- Cytochrome P450 CYP1A2 (1)
- DCTB (1)
- DP laser induced plasma (1)
- Dairy cows (1)
- Damaging mechanism (1)
- Detection limits (1)
- Detector efficiency (1)
- Detektorvergleich (1)
- Diatomic molecule (1)
- Dielectric barrier discharge (1)
- Digital (1)
- Digital transformation (1)
- Dissolution (1)
- Double-pulse LIBS (1)
- Dried droplet (1)
- Droplet (1)
- Droplets (1)
- Drugs on bills (1)
- Dual mode (1)
- Durability (1)
- Dyes (1)
- EC-LC-MS (1)
- EC/LC/MS (1)
- EC/MS (1)
- ECRM (1)
- EDS-TM001 (1)
- EDX (1)
- EDX-SEM (1)
- EDXD (1)
- ESEM (1)
- ESR (1)
- Echelle (1)
- Electrochemistry (1)
- Element determination (1)
- Elemental analytical mehtods (1)
- Elemental tagging (1)
- Emission standard (1)
- Emission/fluorescence ratio (1)
- Encapsulation (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Energy transfer (1)
- Environment (1)
- Environmental monitoring (1)
- Environmental quality standard (EQS) (1)
- Enzyme-Linked Immunosorbent Assay (1)
- Enzyme-linked immunosorbent assay (1)
- Equivalence (1)
- Euro banknotes (1)
- Evaporation of droplets (1)
- Explosive (1)
- FT-Raman spectroscopy (1)
- FWHM (1)
- Fe nanoparticles metabolism (1)
- Fe-based highly active ionic liquids (1)
- Feces (1)
- Feed (1)
- Feeding regime (1)
- Ferrocene (1)
- Field flow fractionation (1)
- Fields (1)
- Five iron oxalate core–shell magnetite nanoparticles catalysts are evaluated as magnetic heterogeneous (1)
- Fixed-points (1)
- Fluorescence spectroscopy (1)
- Fluorescent glass (1)
- Focal distance (1)
- Foodstuffs (1)
- Fourier transform spectroscopy (1)
- Fungicide (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- Gadolinium-uptake (1)
- Gas-phase NMR spectroscopy (1)
- Gd based contrast agents (1)
- Geochemical analysis (1)
- Germanium sulfide (1)
- Glow discharge (1)
- Glycan microarray (1)
- Gold (1)
- Gold-Nanopartikel (1)
- Grafting (1)
- Grimm type glow discharge (1)
- Guest complexe (1)
- HDEHP (1)
- HILIC (1)
- HILIC chromatography (1)
- HRMS (1)
- Hapten immunoassay (1)
- Heavy crude oil (1)
- High performance liquid chromatography (1)
- High resolution glow discharge mass (1)
- High-resolution continuum source absorption spectrometry (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hollow cathode (1)
- Homogenität (1)
- Hormone (1)
- Human serum (1)
- Humic acid (1)
- Humic colloids (1)
- Hydrodynamic chromatography (HDC) (1)
- Hyphenated technique (1)
- ICCD CCD (1)
- IDMS (1)
- IR-MALDI (1)
- ITS-90 (1)
- IgG (1)
- Imaging MS (1)
- Immunization monitoring (1)
- Immunoassays (1)
- Impurities (1)
- In situ (1)
- In situ analysis (1)
- In-situ-Analyse (1)
- Integrating sphere (1)
- Interferometry (1)
- Internal standard (1)
- Inverse Abel Transform (1)
- Ion exchanged soda lime silicate glass (1)
- Ion mobility spectrometry (1)
- Ionic liquid (1)
- Ionic liquids (1)
- Ionmobility spectrometry (1)
- Iposomes (1)
- Iron nanoparticles (1)
- Iron ore (1)
- Iron-sucrose nanoparticles (1)
- Isotope (1)
- Isotope dilution mass spectrometry (1)
- Isotope ratios (1)
- Key comparison (1)
- Kolloidale Suspensionen (1)
- Konduktometrische Titration (1)
- Kramers background (1)
- Kreuzreaktivität (1)
- Kupfer (1)
- LA-ICP-MS based immunoassays (1)
- LA-ICP-OES (1)
- LC-MS (1)
- LCMSMS (1)
- Langmuir isotherm (1)
- Laser Induced Breakdown Spectroscopy (1)
- Laser ablation ICP-MS (1)
- Laser desorption ionization (1)
- Laser induced breakdown spectroscopy (LIBS) (1)
- Laser induced fluorescence (1)
- Laser-induced breakdown spectroscopy (LIBS) (1)
- Laser-spark (1)
- Laserablation (1)
- Light diffraction (1)
- Linear correlation (1)
- Liquid chromatography at critical conditions (1)
- Liquid matrix (1)
- Liver function tests (1)
- Luminescence (1)
- MALDI Massenspektrometrie (1)
- MALDI TOF mass spectrometry (1)
- MALDI mass spectrometry (1)
- MRI contrast agent (1)
- Machine learning (1)
- Magnetic coreshell nanocatalysts (1)
- Magnetic nanocatalyst (1)
- Magnetic resonance imaging (1)
- Magnetische Nanopartikel (1)
- Magnetpartikel (1)
- Manipulation (1)
- Mass spectrometry imaging (1)
- Material identification (1)
- Matrix (1)
- Matrix calculation (1)
- Matrix evaporation (1)
- Matrix influence (1)
- Matrix method (1)
- Matrix segregation (1)
- Matrix separation (1)
- Matrix-method (1)
- Matrixeffekte (1)
- Measuremment uncertainty (1)
- Mechanochemistry (1)
- Mega-dalton (1)
- Memory effect (1)
- Metal (1)
- Metal organic compounds (1)
- Metals (1)
- Metrology (1)
- Metrology in chemistry (1)
- Micro spot (1)
- Micro-hardness (1)
- Microdroplet generator (1)
- Microemulsion (1)
- Microparticles (1)
- Microphony (1)
- Microstructure (1)
- Mikropartikel (1)
- Mitigation (1)
- Modeling (1)
- Modelling (1)
- Modern art (1)
- Molecular absorption (1)
- Molecular masses (1)
- Molten glass (1)
- Monte Carlo simulation (1)
- Multi-element screening (1)
- Multiphoton fabrication (1)
- Multiplexing (1)
- Multivariate classification (1)
- Nano (1)
- Nano-carrier (1)
- Nanocrystals (1)
- Nanomaterials (1)
- Nanon (1)
- Nanoparticle characterization (1)
- Nanoparticles with same nominal diameter (1)
- Nifedipine (1)
- Nile red (1)
- Noncontact measurement technique (1)
- Noncontact ultrasonic transportation (1)
- Oberflächenfunktionalisierung (1)
- Oberflächenwasser (1)
- Online NMR (1)
- Online monitoring (1)
- Optically saturated fluorescence (1)
- Organic peroxides (1)
- Organophosphate agrochemicals (1)
- Orthogonal double pulse plasma (1)
- Oxidative metabolism (1)
- Parallel computing (1)
- Parallelising mode (1)
- Particle size range (1)
- Particles (1)
- Particulate matter (1)
- Peptide library (1)
- Pesticide (1)
- Pharmaceuticals (1)
- Pharmazeutische Cokristalle (1)
- Photo-Fenton oxidation (1)
- Photoacoustic spectroscopy (1)
- Photoluminescence (1)
- Photon generation yield (1)
- Pigments (1)
- Pin sample (1)
- Plants (1)
- Plasma diagnostics (1)
- Plasma spectrum analysis (1)
- Plasma temperature (1)
- Plume (1)
- Pollen germination (1)
- Pollen tube (1)
- Polycapillary X-ray optics (1)
- Polymerisation (1)
- Polymers (1)
- Polymerwissenschaften (1)
- Polystyrol (1)
- Polyurethane (1)
- Portland cement (1)
- Post-breakdown laser induced plasma (1)
- Precision (1)
- Pressure field (1)
- Primary reference gas mixtures (1)
- Primary standards (1)
- Principal component analysis (1)
- Process Control (1)
- Process Monitoring (1)
- Process analytical technology (1)
- Process control (1)
- Public funding (1)
- Pulse duration (1)
- Pure copper (1)
- Purification (1)
- Purity (1)
- Pyrotechnic articles (1)
- QuEChERS (1)
- Quality assurance (1)
- Quantitative NMR spectroscopy (1)
- Quantitative Online-NMR-Spektroskopie (1)
- Quantitative analysis (1)
- Quantum dots (1)
- Quantum yield (1)
- Quaternary oxides (1)
- RESS (1)
- Radiometry (1)
- Radon transform (1)
- Radon transform technique (1)
- Radon transform tomography of SP (1)
- Raman microscopy (1)
- Raman microspectroscopy (1)
- Reabsorption (1)
- Reaction products (1)
- Reactive azo dye degradation (1)
- Reconstructed ion chromatograms (1)
- Recycling (1)
- Reference (1)
- Reference measurements (1)
- Reference value (1)
- Reference value uncertainty (1)
- Reference-free XRF (1)
- Removal (1)
- Renewable copolymers (1)
- Reorganization (1)
- Ressortforschung (1)
- Ressortforschungseinrichtung (1)
- Rhodamine 6G (1)
- RoHS (1)
- Röntgenbeugung (1)
- SDHI-fungicide (1)
- SEC (1)
- SEM/EDS (1)
- SERS (1)
- SF-ICP-MS (1)
- SI (1)
- Saliva (1)
- Sample dissolution (1)
- Sample enrichment (1)
- Sample loss (1)
- Sample preparation (1)
- Scattering (1)
- Sector field mass spectrometry (1)
- Semi-lens (1)
- Sensitivity (1)
- Sensitized magnetic nanocatalysts (1)
- Serum (1)
- Shelf life (1)
- Side-window X-ray tube (1)
- Silicon (1)
- Silver (1)
- Simulation (1)
- Single Cell Analysis (1)
- Singlet oxygen (1)
- Singulettsauerstoff (1)
- Small objects (1)
- Sol-gel processes (1)
- Solar grade silicon (1)
- Solid phase extraction (1)
- Solvatochromism (1)
- Sonic spray (1)
- Sonic spray ionization (1)
- Sonochemical synthesis (1)
- Sound pressure (1)
- SpICP-MS (1)
- Spark-OES (1)
- Spatial heterodyne spectroscopy (1)
- Spatial investigations (1)
- Species-unspecific on-line isotope dilution (1)
- Spectral Modeling (1)
- Spectral correction (1)
- Spectral fluorescence standard (1)
- Spectrochemical analysis (1)
- Spectrometer (1)
- Spectrometer efficiency (1)
- Sporopollenin (1)
- Stability (1)
- Stable isotope (1)
- Standard (1)
- Standard-less analysis (1)
- Steel (1)
- Structure (1)
- Sulfate attack (1)
- Supercritical fluids (1)
- Surface coating (1)
- Surface-enhanced Raman scattering (1)
- Suspended particulate matter (1)
- Swelling (1)
- Synchrotron-radiation (1)
- Synthetic organic pigments (1)
- TATP (1)
- TEM (1)
- Terrorism (1)
- Thermal degradation (1)
- Thiol-ene click chemistry (1)
- Threshold values (1)
- ToF-SIMS (1)
- Toxicology (1)
- Trace elements (1)
- Transformation product (1)
- Transformation products (1)
- Transmission (1)
- Triacetone triperoxide (1)
- Tributyltin (TBT) (1)
- Two-dimensional off-line coupling (1)
- UPLC (1)
- UV degradation (1)
- Ultra high purity (1)
- Ultraschallfalle (1)
- Ultrasonic acoustic resonator (1)
- Ultrasonic trap (1)
- Urine (1)
- Vacuum distillation (1)
- Validation (1)
- Validierung (1)
- Wastewater marker (1)
- Water treatment (1)
- Wissenschaftliche Politikberatung (1)
- X-ray tube spectra (1)
- X-ray tube spectrum (1)
- X-ray-scattering (1)
- XRD (1)
- Xerogel (1)
- ZRM (1)
- Zementhydratation (1)
- Zeta-Potential (1)
- Zirconium (1)
- glass fibre paper (1)
- ion optics (1)
- muXRF (1)
- pH-Abhängigkeit (1)
- sensing (1)
- spray (1)
- surface enhanced Raman scattering (1)
- µSpot (1)
- ß-amino-cyclodextrin (1)
- “Click” chemistry (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (32)
- P Präsident (29)
- P.0 Präsident und andere (29)
- 1.1 Anorganische Spurenanalytik (15)
- 6 Materialchemie (12)
- 6.3 Strukturanalytik (8)
- 1.6 Anorganische Referenzmaterialien (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (6)
- 1.8 Umweltanalytik (5)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
Eingeladener Vortrag
- nein (46)
RATIONALE
Polymer sample spots for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) prepared by the dried-droplet method often reveal ring formation accompanied by possible segregation of matrix and sample molecules as well as of the polymer homologs itself. Since the majority of sample spots are prepared by this simple and fast method, a matrix or sample preparation method that excludes such segregation has to be found.
METHODS
Three different ionic liquid matrices based on conventionally used aromatic compounds for MALDI-TOF MS were prepared. The formation of ionic liquids was proven by 1H NMR spectroscopy. MALDI-Imaging mass spectrometry was applied to monitor the homogeneity.
RESULTS
Our results show a superior sample spot homogeneity using ionic liquid matrices. Spots could be sampled several times without visible differences in the mass spectra. A frequently observed loss of matrix in the mass spectrometer vacuum was not observed. The necessary laser irradiance was reduced, which resulted in less polymer fragmentation.
CONCLUSIONS
Ionic liquid matrices can be used to overcome segregation, a typical drawback of conventional MALDI dried-droplet preparations. Homogeneous sample spots are easy to prepare, stable in the MS vacuum and, thereby, improve the reproducibility of MALDI.
Laser-induced breakdown spectroscopy (LIBS) is a fast and versatile technique for (semi) quantitative element analysis of solids, liquids, gases, and particulate matter. The LIBS method is used for optical sensing in various branches of industrial production. In the contribution we review some of our recent results on LIBS analysis of slags from secondary metallurgy in industrial steel making. Major oxides in steel slags are measured at-line and after homogenization using a calibration-free (CF) method. Two approaches for CF analysis based on the Boltzmann plot method and on the calculation of synthetic spectra are compared for the analysis of quaternary oxides. We also present the research in cooperation with our industrial partners in the process-analytical chemistry network PAC.
Tomography of a laser-induced plasma in air is performed by inverse Radon transform of angle-resolved plasma images. Plasmas were induced by single laser pulses (SP), double pulses (DP) in collinear geometry, and by a combination of single laser pulses with pulsed arc discharges (SP-AD). Images of plasmas on metallurgical steel slags were taken at delay times suitable for calibration-free laser-induced breakdown spectroscopy (CFLIBS). Delays ranged from few microseconds for SP and DP up to tens of microseconds for SP-AD excitation. The white-light and the spectrally resolved emissivity ε(x,y,z) was reconstructed for the three plasma excitation schemes. The electron number density Ne(x,y,z) and plasma temperature Te(x,y,z) were determined from Mg and Mn emission lines in reconstructed spectra employing the Saha-Boltzmann plot method. The SP plasma revealed strongly inhomogeneous emissivity and plasma temperature. Re-excitation of plasma by a second laser pulse (DP) and by an arc discharge (SP-AD) homogenized the plasma and reduced the spatial variation of ε and Te. The homogenization of a plasma is a promising approach to increase the accuracy of calibration-free LIBS analysis of complex materials.
From simple homopolymers to functionalized, 3-dimensional structured copolymers, the complexity of polymeric materials has become more and more sophisticated. With new applications for instance in the semiconductor or pharmaceutical industry, the requirements for the characterization have risen with the complexity of the used polymers. For each additional distribution, an additional dimension in analysis is needed. Small, often isomeric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector, but affect the properties of materials significantly. For a drug delivery system for example, the degree of branching and branching distribution is crucial for the formation of micelles. Instead of a complicated, time consuming and/or expensive 2d-chromatography or ion mobility spectrometry (IMS) method, that also has its limitations, in this work a simple approach using size exclusion chromatography (SEC) coupled with electrospray ionization mass spectrometry (ESI) is proposed. The online coupling allows the analysis of reconstructed ion chromatograms (RIC) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities. Although some microstructural heterogeneities like short chain branching can for large polymers be characterized with methods such as light scattering, for oligomers where the heterogeneities just start to form and their influence is at the maximum, they are inaccessible with these methods. It is also shown, that with a proper calibration even quantitative information can be obtained. This method is suitable to detect small differences in e. g. branching, 3d-structure, monomer sequence or tacticity and could potentially be used in routine analysis to quickly determine deviations.
Statistical ethylene oxide (EO) and propylene oxide (PO) copolymers of different monomer compositions and different average molar masses additionally containing two kinds of end groups (FTD) were investigated by ultra high pressure liquid chromatography under critical conditions (UP-LCCC) combined with electrospray ionization time-of flight mass spectrometry (ESI-TOFMS).
Theoretical predictions of the existence of a critical adsorption point (CPA) for statistical copolymers with a given chemical and sequence distribution1 could be studied and confirmed. A fundamentally new approach to determine these critical conditions in a copolymer, alongside the inevitable chemical composition distribution (CCD), with mass spectrometric detection, is described. The shift of the critical eluent composition with the monomer composition of the polymers was determined. Due to the broad molar mass distribution (MMD) and the presumed existence of different end group functionalities as well as monomer sequence distribution (MSD), Gradient separation only by CCD was not possible. Therefore, isocratic separation conditions at the CPA of definite CCD fractions were developed. Although the various present distributions partly superimposed the separation process, the goal of separation by end group functionality was still achieved on the basis of the additional dimension of ESI-TOF-MS. The existence of HO-H besides the desired allylO-H end group functionalities was confirmed and their amount estimated. Furthermore, indications for a MSD were found by UPLC/MS/MS measurements. This approach offers for the first time the possibility to obtain a fingerprint of a broad distributed statistical copolymer including MMD, FTD, CCD, and MSD.
Simultaneous characterization of poly(acrylic acid) andpolysaccharide polymers and copolymers
(2020)
Copolymer products that result from grafting acrylic acid and other hydrophilicmonomers onto polysaccharides have recently gained significant interest in researchand industry. Originating from renewable sources, these biodegradable, low toxicity,and polar copolymer products exhibit potential to replace polymers from fossil sourcesin several applications and industries. The methods usually employed to character-ize these copolymers are, however, quite limited, especially for the measurement ofbulk properties. With more sophisticated applications, for example, in pharmaceu-tics requiring a more detailed analysis of the chemical structure, we describe a newapproach for this kind of complex polymers. Our approach utilizes chromatographyin combination with several detection methods to separate and characterize reactionproducts of the copolymerization of acrylic acid and chemically hydrolyzed starch.These samples consisted of a mixture of homopolymer poly (acrylic acid), homopoly-mer hydrolyzed starch, and – in a lower amount – the formed copolymers. Several chro-matographic methods exist that are capable of characterizing either poly (acrylic acid)or hydrolyzed starch. In contrast, our approach offers simultaneous characterization ofboth polymers. The combination of LC and UV/RI offered insight into the compositionand copolymer content of the samples. Size exclusion chromatography experimentsrevealed the molar mass distribution of homopolymers and copolymers. FTIR inves-tigations confirmed the formation of copolymers while ESI-MS gave more details onthe end groups of hydrolyzed starches and poly (acrylic acids). Evidence of copolymerstructures was obtained through NMR measurements. Finally, two-dimensional chro-matography led to the separation of the copolymers from both homopolymers as wellas the additional separation of sodium clusters. The methods described in this work area powerful toolset to characterize copolymerization products of hydrolyzed starch andpoly(acrylic acid). Together, our approach successfully correlates the physicochemicalproperties of such complex mixtures with their actual composition.
The meeting was organised by the European Commission’s Joint Research Centre and held at the JRC-Geel site on 22–23 February 2018. It was a follow-up of a similar meeting held in 2009. The objective of the meeting was to exchange information about ongoing publicly funded reference material (RM) production, identify areas of interest for future specific RMs, including certified reference material (CRM) developments, investigate potential areas of collaboration, and to identify areas which may be of a lower importance in the future for a specific RM producer. The benefit of exchanging such information is to avoid duplication of efforts in RM production, make better use of public funds by potentially matching competencies, and to address problems that are common to publicly funded RM producers.
This work presents results of investigations towards the emission of chemical reaction products and sound pressure during an outdoor and an indoor firework display. Potentially harmful and toxic gases, and aerosols, were measured as well as sound pressures. Aerosols were measured with a Differential Mobility Analyzer (DMA) as well as a Laser Particle Counter. The focus was on particles with diameters between 11 nm and 20 µm. A transportable Fourier Transform Infrared (FTIR) spectroscopy detector registered the concentrations of emitted reaction gases, simultaneously. During the outdoor firework display, peak particle concentrations of >550000 particles cm-3, equivalent to a mass concentration of approximately 3.95 mg m-3, were detected, revealing a concentration maximum at approximately 175 nm particle diameter. The time-averaged particle mass concentration did not exceed 1.58 mg m-3 over 15 minutes. Due to the large distances (110 m) to the firing points, no significant harmful or toxic gas concentrations were measured during the entire firework display. In contrast, concentrations of sulphur dioxide (SO2) rose after an indoor firework display in a large event hall. On two days, more than 23000 particles cm-3 (which equates to a mass concentration of approximately 0.41 mg m-3) were detected when the hall ventilation was turned off, and more than 11000 particles cm-3 (which equates to a mass concentration of approximately 1.18 mg m-3) when the hall ventilation was activated. Concentration maxima appeared at approximately 300 nm particle diameter. The time-averaged particle concentrations in this case did not exceed 0.56 mg m-3 (over 15 minutes).
The results of investigations on the emission of particulate matter from three outdoor firework displays are presented. During these events, possibly harmful and toxic aerosol emissions were measured. Aerosols in the size range from 30 to 450 nm were detected. The maxima in the observed particle size distribution were between 80 and 175 nm, and the highest value determined was ~1.3 · 106 particles per cm³, while the highest mass concentration was approximately 1.8 mg m–3. The time-averaged particle mass concentration did, however, not exceed 0.7 mg m–3 (over 15 min).
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was utilized for spatially resolved bioimaging of the distribution of silver and gold nanoparticles in individual fibroblast cells upon different incubation experiments. High spatial resolution was achieved by optimization of scan speed, ablation frequency, and laser energy. Nanoparticles are visualized with respect to cellular substructures and are found to accumulate in the perinuclear region with increasing incubation time. On the basis of matrix-matched calibration, we developed a method for quantification of the number of metal nanoparticles at the single-cell level. The results provide insight into nanoparticle/cell interactions and have implications for the development of analytical methods in tissue diagnostics and therapeutics.
The need for standardization in fluorescence measurements to improve quality assurance and to meet regulatory demands is addressed from the viewpoint of National Metrology Institutes (NMIs). Classes of fluorescence standards are defined, including instrument calibration standards for the determination and correction of instrument bias, application-specific standards based on commonly used fluorescent labels, and instrument validation standards for periodic checks of instrument performance. The need for each class of standard is addressed and on-going efforts by NMIs and others are described. Several certified reference materials (CRMs) that have recently been developed by NMIs are highlighted. These include spectral correction standards, developed independently by both NIST and BAM (Germany), and fluorescence intensity standards for flow cytometry, developed by NIST. In addition, future activities at both institutes are addressed such as the development of day-to-day intensity standards.
The improved Monte-Carlo (MC) method for standard-less analysis in laser induced breakdown spectroscopy (LIBS) is presented. Concentrations in MC LIBS are found by fitting model-generated synthetic spectra to experimental spectra. The current version of MC LIBS is based on the graphic processing unit (GPU) computation and reduces the analysis time down to several seconds per spectrum/sample. The previous version of MC LIBS which was based on the central processing unit (CPU) computation requested unacceptably long analysis times of 10's minutes per spectrum/sample. The reduction of the computational time is achieved through the massively parallel computing on the GPU which embeds thousands of co-processors. It is shown that the number of iterations on the GPU exceeds that on the CPU by a factor > 1000 for the 5-dimentional parameter space and yet requires > 10-fold shorter computational time. The improved GPU-MC LIBS outperforms the CPU-MS LIBS in terms of accuracy, precision, and analysis time. The performance is tested on LIBS-spectra obtained from pelletized powders of metal oxides consisting of CaO, Fe2O3, MgO, and TiO2 that simulated by-products of steel industry, steel slags. It is demonstrated that GPU-based MC LIBS is capable of rapid multi-element analysis with relative error between 1 and 10's percent that is sufficient for industrial applications (e.g. steel slag analysis). The results of the improved GPU-based MC LIBS are positively compared to that of the CPU-based MC LIBS as well as to the results of the standard calibration-free (CF) LIBS based on the Boltzmann plot method.
An efficient solid phase extraction (SPE) method using bis-(2-ethylhexyl)-phosphate (HDEHP) coated reverse phase C18 support has been developed for the pre-concentration of Gadolinium (Gd) and Gd contrast agents widely used in magnetic resonance imaging (MRI). Enrichment of Gd in the ionic form has been compared with strong cation exchange material Chromabond SA (SCX), weak ion exchange material Chelex-100 and also with lanthanide specific HDEHP modified reverse phase C18. The determination of Gd and its complexes after enrichment were performed using inductively coupled plasma mass spectrometry (ICP-MS) and on the basis of 158Gd. Among the three SPE materials, HDEHP coated reverse phase C18 SPE has been found to be most efficient, yielding a hundredfold Gd enrichment with > 95% recovery for linear and cyclic contrast agents like Gd-DTPA (Magnevist), Gd-DOTA (Dotarem), Gd-BOPTA (Multihance), and Gd-BT-DO3A (Gadovist). The developed SPE method has been successfully applied to the surface water and waste water samples originated from different places in Berlin, Germany. The results were in good agreement with the results obtained with direct measurement with ICP-MS. The developed pre-concentration method can be efficiently used for the determination of trace levels of gadolinium in the environment even with less sensitive analytical techniques.
Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples.
A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling.
In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl2F2 as gaseous halogenation modifier was investigated. Especially for the carbide forming elements the sensitivity was improved and the memory effects were significantly reduced. Calibration was performed by external calibration and standard addition with aqueous standard solutions added directly into the sample boats. Absolute limits of detection (3s-criterion) range between 0.1 ng (Cd) and 9 ng (Fe) which corresponds to relative values of 0.1 mg kg-1 and 1.6 mg kg-1, respectively, taking 5 mg as typical sample mass. The detection limits are sufficient to monitor the element contents of plastic materials according to European directives such as European directive on the safety of toys. The developed ETV-ICP-OES method allows a fast analysis with a high sample throughput (3 minutes per analysis), low sample consumption and good trueness and precision for the analyzed elements. Sample preparation is reduced to ashing the samples in a muffle furnace. Furthermore, measurements are possible regardless of the chemical form in the additives. For verification the results obtained with the developed method were compared with measurement results of independent methods ICP-MS/OES after digestion. In addition Cd, Cr and Pb were determined in a solid plastic reference material BAM-H010 to confirm the applicability and accuracy of the method.
ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment.
We present paper-based test strips for chemical sensing with surface enhanced Raman scattering as detection method. The test strips are prepared on glass fibre paper with silver nanoparticles and a spray method with an airbrush spray setup as a low cost fabrication approach. The properties of the test strips are investigated with three classical Raman analytes rhodamine 6G, 4-aminothiophenol and adenine and optimized for a good reproducibility of the intensity measurements. All test analytes can be identified at low concentrations. For adenine, a concentration series from 10⁻⁴ M to 10⁻⁸ M is measured and the calibration data can be fitted and evaluated with a Langmuir isotherm model. The optimized test strips are applied for the identification of two antibiotics enoxacin and enrofloxacin.
One major drawback of matrix-assisted laser desorption/ionization (MALDI) is still the relatively poor pulse-to-pulse reproducibility of the signal intensity. This problem, caused by insufficient homogeneity in the matrix/analyte co-crystallization, is usually circumvented by averaging the detected ion intensity over several shots. However, during the consecutive laser pulses, the applied matrix gets depleted and only a number of subsequent experiments can be done on the same sample spot. In order to achieve the desired long-term stability in combination with a sufficient pulse-to-pulse reproducibility, recently liquid MALDI matrices have been introduced. This contribution demonstrates the promising combination of liquid matrices with high repetition rate lasers for atmospheric pressure MALDI (AP-MALDI). To demonstrate the robustness of the new approach, two different kinds of liquid matrices were used in combination with both a typical flashlamp pumped 15 Hz laser and a diode pumped solid state laser operated at 5 kHz. The latter showed a stable ion signal over more than 3,500,000 consecutive laser pulses.
Among the large number of new ambient ionization schemes in the last few years, dielectric barrier discharge (DBD) has witnessed special attention. In this contribution a versatile dual mode DBD is introduced and characterized by means of optical emission spectroscopy and time-of-flight mass spectrometry. A direct comparison of the individual results from spectroscopy, spectrometry and transient current/voltage consumption gives evidence for the existence of two individual operational mechanisms. The first is driven by rapid transient changes in the potential difference between the two electrodes over time (usually denoted as the homogeneous mode), while the second is caused at high static potential differences (leading to filamentary discharges). The transient versus steady-state characteristics of the individual discharge origin suggest the driving force for the current flow to be inductive and capacitive, respectively. In most cases of dielectric barrier plasmas both discharge types coexist as competitive ion formation channels, however, detailed plasma characteristics of DBDs operated under different conditions allow for a clear distinction of the individual contributions. In this way, two characteristic product channels for the ionization of ambient water could be observed resulting in the generation of either preferentially protonated water clusters or ammonium water clusters. Careful tuning of the operation parameters of the discharge device allows an operation predominated by either of the two modes. As a consequence, facile switching into the desired operational mode results in either protonated molecules or ammoniated molecules of the analyte. Plasma characteristics for both moieties were evaluated and cross-correlated on the basis of several factors including: the production of reagent ions, the individual appearance of current/voltage profiles, UV/Vis spectroscopy, voltage and flux dependence and the individual response to test compounds. Although the filamentary mode has been already discussed in the literature to induce fragmentation processes, no experimental evidence for analyte dissociation could be found in the case of the test compounds used
Optical elemental analysis in the gas phase typically relies on electrically driven plasmas. As an alternative approach, laser-induced plasmas (LIPs) have been suggested but have so far been only scarcely used.
Here, a novel signal enhancement strategy for laser-based airborne plasma optical Emission spectroscopy for gas phase analytics is presented. In contrast to an electrically driven plasma, in the laser-induced analogue dynamic matter transport equilibrium builds up. The latter results in a rarefied density regime in the plasma core itself, surrounded by an area of compressed matter. The central rarefaction leads to a decrease in plasma intensity and analyte number density, both of which are detrimental for analytical purposes. Since the repetitive ignition of LIPs is a transient process, a restoration of the former gaseous medium by other dynamically equilibrated diffusion processes would be favourable. The presented combination of an airborne LIP and an ultrasonic acoustic resonator yields a fourfold signal enhancement while the Background contribution of ubiquitous air is at the same time effectively suppressed. Since the entire enhancement effect occurs without contact, no additional sources for abrasive sample contamination are introduced.
An airborne laser plasma is suggested as an ambient ion source for mass spectrometry. Its fundamental physical properties, such as an excellent spatial and temporal definition, high electron and ion densities and a high effective cross section in maintaining the plasma, make it a promising candidate for future applications. For deeper insights into the plasma properties, the optical plasma emission is examined and compared to mass spectra. The results show a seemingly contradictory behavior, since the emitted light reports the plasma to almost entirely consist of hot elemental ions, while the corresponding mass spectra exhibit the formation of intact molecular species. Further experiments, including time- resolved shadowgraphy, spatially resolved mass spectrometry, as well as flow-dependent emission spectroscopy and mass spectrometry, suggest the analyte molecules to be formed in the cold plasma vicinity upon interaction with reactive species formed inside the hot plasma center. Spatial separation is maintained by concentrically expanding pressure waves, inducing a strong unidirectional diffusion. The accompanying rarefaction inside the plasma center can be compensated by a gas stream application. This replenishing results in a strong increase in emission brightness, in local reactive species concentration, and eventually in direct mass spectrometric sensitivity. To determine the analytical performance of the new technique, a comparison with an atmospheric pressure chemical ionization (APCI) source was conducted. Two kitchen herbs, namely, spearmint and basil, were analyzed without any sample pretreatment. The presented results demonstrate a considerably higher sensitivity of the presented laser-spark ionization technique.
Encapsulation of hydrophobic dyes in polystyrene micro- and nanoparticles via swelling procedures
(2011)
Aiming at the derivation of a generalized
procedure for the straightforward preparation of particles
fluorescing in the visible and near-infrared (NIR) spectral
region, different swelling procedures for the loading of the
hydrophobic polarity-probe Nile Red into nano- and
micrometer sized polystyrene particles were studied and
compared with respect to the optical properties of the
resulting particles. The effect of the amount of incorporated
dye on the spectroscopic properties of the particles was
investigated for differently sized beads with different
surface chemistries, i.e., non-functionalized, aminomodified
and PEG-grafted surfaces. Moreover, photostability
and leaking studies were performed. The main criterion
for the optimization of the dye loading procedures was a
high and thermally and photochemically stable fluorescence
output of the particles for the future application of these
systems as fluorescent labels.
Metal tags find application in a multitude of biomedical systems and the combination with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) offers an opportunity for multiplexing. To lay the foundation for an increase of the signal intensities in such processes, we herein present a general approach for efficient functionalization of a well-defined metal oxido cluster [Bi6O4(OH)(4)(SO3CF3)(6)(CH3CN)(6)].2 CH3CN (1), which can be realized by selecting 7mer peptide sequences via combinatorial means from large one-bead one-compound peptide libraries. Selective cluster-binding peptide sequences (CBS) for 1 were discriminated from non-binders by treatment with H2S gas to form the reduction product Bi2S3, clearly visible to the naked eye. Interactions were further confirmed by NMR experiments. Extension of a binding peptide with a maleimide linker (Mal) introduces the possibility to covalently attach thiol-bearing moieties such as biological probes and for their analysis the presence of the cluster instead of mononuclear entities should lead to an increase of signal intensities in LA-ICP-MS measurements. To prove this, CBS-Mal was covalently bound onto thiol-presenting glass substrates, which then captured 1 effectively, so that LA-ICP-MS measurements demonstrated drastic signal amplification compared to single lanthanide tags.
Mechanochemical synthesis of [Zn3(C2O4)3(4,4'-bipy)4] and its reorganization at high temperatures
(2014)
The metal organic layered structure catena-(bis(µ2-4,4'-bipyridine)-tris(µ2-oxalato)-bis(4,4'-bipyridine)-tri-zinc(ii)) ([Zn3(C2O4)3(4,4'-bipy)4]) was synthesized mechanochemically applying three different routes. The synthesis succeeded by i) simultaneously neat grinding the three starting materials zinc acetate dihydrate, oxalic acid dihydrate and 4,4'bipyridine, ii) grinding two compounds and adding the third afterwards, independent of the sequence. The products were characterized using powder X-ray diffraction, Raman spectroscopy, gas adsorption measurements, and scanning electron microscopy. Temperature-dependent synchrotron XRD measurements revealed that the monoclinic structure of [Zn3(C2O4)3(4,4'-bipy)4] rearranges reversibly to a higher ordered orthorhombic structure [Zn(C2O4)(4,4'-bipy)] at high temperatures.
A method for the determination of 22 trace impurities in solar grade silicon after dissolution in a mixture of HF and HNO3 and subsequent matrix evaporation is reported. The presented method involves a simple, inexpensive, one-vessel sample preparation apparatus design. The recoveries of B, Na, Mg, Al, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Mo, Sb, W, and Tl at 250 µg kg-1 level are in the range of 93 to 108%. After careful selection of monitored isotopes and their respective resolutions, a sector field mass spectrometer has been used to carry out the measurements. Limits of determination down to 120 ng kg-1 have been obtained using a calibration by three-point standard addition. The method was tested on diluted NIST SRM 57b silicon powder as well as on synthetic test samples and also applied successfully on raw solar grade silicon samples in an interlaboratory comparison including NAA.
Methods for the determination of boron in various matrices described in the literature usually employ complexing agents like mannitol to retain the volatile boron species during matrix evaporation steps. However, also relatively high boron recoveries from silicon containing samples have been reported when no complexing agents were added to the digestion acids. The mechanism behind this matrix-dependant recovery has been investigated by studying the boron recovery in the analysis of solar grade silicon. It was found that the NH4+ ion formed by the reduction of nitric acid during sample digestion is responsible for the higher recovery of boron, which leads to a possible analysis method without the use of complexing agents if the sample preparation procedure is carefully optimized.
Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody
(2009)
The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods.
High performance liquid chromatography (HPLC) was hyphenated with a previously reported carbamazepine-specific enzyme-linked immunosorbent assay (ELISA) as a screening approach to water analysis in order to identify possible interferences from transformation products. Treated wastewater was analysed and three substances were recognized by the antibody besides carbamazepine: the metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 2-hydroxycarbamazepine plus the structurally not obviously related antihistamine cetirizine. The molar cross-reactivity against cetirizine was found to be pH-dependent and assessed to be 400% at pH 4.5 and 22% at pH 10.5. Performing the ELISA at pH 10.5 greatly improved the accuracy when carbamazepine was determined in surface and wastewater samples.
Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody.
The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters.
Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LCMS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively.
This paper presents a numerical and an experimental procedure to obtain the pressure field in single-axis acoustic levitators. Numerically, the pressure field is determined by a matrix method based on the Rayleigh integral that take into account the multiple wave reflections that occur between the transducer and the reflector. The numerical pressure field is compared with the acoustic pressure measured by an earplug microphone, that is connected to a hollow needle. The tip of the needle is moved by a µm translation stage through the field and the signal is recorded using a lock-in amplifier locked to the levitator frequency. The pressure field obtained numerically show good agreement with that obtained experimentally.
This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6 ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Crossreactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1 cm2 of one banknote by swabbing 1 cm2: 0, 14, and 21 pg/cm2. Moreover, three notes of different denominations revealed high cocaine concentration; 1.1 mg/note, and twice 55 μg/note.
High-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GF-MAS) was employed for determining adsorbable organic chlorine (AOCl) in water. Organic chlorine was indirectly quantified by monitoring the molecular absorption of the transient aluminum monochloride molecule (AlCl) around a wavelength of 261.42 nm in a graphite furnace. An aluminum solution was used as the molecularforming modifier. A zirconium coated graphite furnace, as well as Sr and Ag solutions were applied as modifiers for a maximal enhancement of the absorption signal. The pyrolysis and vaporization temperatures were 600 °C and 2300 °C, respectively. Non-spectral interferences were observed with F, Br, and I at concentrations higher than 6 mg L-1, 50 mg L-1, and 100 mg L-1, respectively. Calibration curves with NaCl, 4-chlorophenol, and trichlorophenol present the same slope and dynamic range, which indicates the chlorine atom specificity of the method. This method was evaluated and validated using synthetic water samples, following the current standard DIN EN ISO 9562:2004 for the determination of the sum parameter adsorbable organic halides (AOX) for water quality. These samples contain 4-chlorophenol as the chlorinated organic standard in an inorganic chloride matrix. Prior to analysis, organic chlorine was extracted from the inorganic matrix via solid-phase extraction with a recovery rate >95%. There were no statistically significant differences observed between measured and known values and for a t-test a confidence level of 95% was achieved. The limits of detection and characteristic mass were found to be 48 and 22 pg, respectively. The calibration curve was linear in the range 0.1–2.5 ng with a correlation coefficient R2 = 0.9986.
A fast and simple method for sulfur quantification in crude oils was developed by using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). For this, heavy crude oil samples were prepared as microemulsion (shake) and injected into a graphite furnace (shut). Finally, the concentration of sulfur was determined by monitoring in situ the transient molecular spectrum of GeS at wavelength 295.205nm after adding a germanium solution as molecular forming agent (and go). Zirconium dioxide in the form of nanoparticles (45–55nm) was employed as a permanent modifier of the graphite furnace. Calibration was done with an aqueous solution standard of ammonium sulfate, and a characteristic mass (m0) of 7.5ng was achieved. The effectiveness of the proposed method was evaluated analizing, ten heavy crude oil samples with Sulfur amounts ranging between 0.3 and 4.5% as well as two NIST standard reference materials, 1620c and 1622e. Results were compared with those obtained by routine ICP-OES analysis, and no statistical relevant differences were found.
Boron isotope amount ratios n(10B)/n(11B) have been determined by monitoring the absorption spectrum of boron monohydride (BH) in a graphite furnace using high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Bands (0→0) and (1→1) for the electronic transition X1Σ+ → A1Π were evaluated around wavelengths 433.1 nm and 437.1 nm respectively. Clean and free of memory effect molecular spectra of BH were recorded. In order to eliminate the memory effect of boron, a combination of 2% (v/v) hydrogen gas in argon and 1% trifluoromethane in argon, an acid solution of calcium chloride and mannitol as chemical modifiers was used. Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression was built. Results obtained around the 433.1 nm and 437.1 nm spectral regions are metrologically compatible with those reported by mass spectrometric methods. Moreover, for the evaluated region of 437 nm, an accuracy of 0.15‰ is obtained as the average deviation from the isotope reference materials. Expanded uncertainties with a coverage factor of k = 2 range between 0.15 and 0.44‰. This accuracy and precision are compatible with those obtained by mass spectrometry for boron isotope ratio measurements.
The mechanism of action of zirconium permanent modifiers on graphite surfaces was investigated in order to understand its influence on the analytical signal in atomic and molecular absorption spectrometry (AAS/MAS). For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. We propose here a mechanism, where ZrO2 acts as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface. No evidence of the formation of zirconium carbide was found. Consequently, as the CaF formation is catalysed by a heterogeneous catalyst, surface modifications with ZrO2 nanoparticles and ZrO xerogels were investigated in order to increase the surface area. Their influence was evaluated in the molecule formation of CaF, CaCl, CaBr, and CaI. Graphite furnace modification with zirconium oxide nanoparticles proves to be the best choice for fluorine analysis with a signal enhancement of more than eleven times with respect a non-coated graphite furnace. However, the influence of zirconium modifications in the analytical signals of Cl, and I is lower than the F signals or even negative in case of the Br. Understanding zirconium modifiers as heterogeneous catalysts offers a new perspective to AAS and MAS, and reveals the potential of surface analytical methods for development of improved permanent modifiers and graphite furnace coatings.