Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (168) (entfernen)
Schlagworte
- LIBS (12)
- ICP-MS (9)
- Acoustic levitation (7)
- ELISA (7)
- LC-MS/MS (7)
- Laser ablation (7)
- Speciation (7)
- Laser induced plasma (5)
- Laser-induced breakdown spectroscopy (5)
- Nanoparticles (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (28)
- P Präsident (24)
- P.0 Präsident und andere (24)
- 1.1 Anorganische Spurenanalytik (14)
- 6 Materialchemie (9)
- 1.6 Anorganische Referenzmaterialien (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (5)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- 6.3 Strukturanalytik (5)
- 1.8 Umweltanalytik (4)
For the investigation of small sample volumes, the use of an acoustic levitator was tested as a `sample holder' for hovering droplets in a synchrotron beam. It might be advantageous to use levitated droplets instead of samples confined in solid holders, especially for the study of crystallization processes where the influence of containing walls has to be minimized. In a first experiment, the crystallization of sodium chloride in a small droplet of aqueous solution has been followed with a time resolution of 30 s. The collected diffraction peaks are compared with data in the ICSD database.
Gated detection with intensified detectors, e.g., ICCDs, is today the accepted approach for detection of plasma emission in laser-induced breakdown spectroscopy (LIBS). However, these systems are more cost-intensive and less robust than nonintensified CCDs. The objective of this paper is to compare, both theoretically and experimentally, the performance of an intensified (ICCD) and nonintensified (CCD) detectors for detection of plasma emission in LIBS. The CCD is used in combination with a mechanical chopper, which blocks the early continuum radiation from the plasma. The detectors are attached sequentially to an echelle spectrometer under the same experimental conditions. The laser plasma is induced on a series of steel samples under atmospheric conditions. Our results indicate that there is no substantial difference in the performance of the CCD and ICCD. Signal-to-noise ratios and limits of detection achieved with the CCD for Si, Ni, Cr, Mo, Cu, and V in steel are comparable or even better than those obtained with the ICCD. This result is further confirmed by simulation of the plasma emission signal and the corresponding response of the detectors in the limit of quantum (photon) noise.
Asymmetrical flow field-flow fractionation (AF4) was applied to characterize aquatic colloids from biological sewage plants and to infer information of colloidal loads, sources, and sinks within the plants, resp. the colloidal interaction with the aqueous phase and the sewage sludge. To characterize the colloids further, especially the distributions of colloid associated heavy metals, the AF4 system was coupled to an inductively coupled plasma mass spectrometer (ICP-MS). The size distribution is determined by AF4 with UV absorbance and fluorescence detection after a calibration by monodisperse polystyrene sulfonate standards (PSS). Samples from different sewage plants and from different depths and locations within a plant were compared. The fulvic/humic acid fraction with a particle diameter dp < 10 nm appeared to be comparable in all samples and decreases only slightly along the plants, whereas larger colloids with dp > 10 nm almost completely passed into the sewage sludge. The concentrations of the initial colloidal heavy metals decreased along the plants.
The stable carbon and nitrogen isotopic composition of urine and milk samples from cattle under different feeding regimes were analysed over a period of six months. The isotope ratios were measured with isotope ratio mass spectrometry (IRMS). The δ13C values of milk and urine were dependent on different feeding regimes based on C3 or C4 plants. The δ13C values are more negative under grass feeding than under maize feeding. The δ13C values of milk are more negative compared to urine and independent of the feeding regime. Under grass feeding the analysed milk and urine samples are enriched in 13C relative to the feed, whereas under maize feeding the 13C/12C ratio of urine is in the same range and milk is depleted in 13C relative to the diet. The difference between the 15N/14N ratios for the two feeding regimes is less pronounced than the 13C/12C ratios. The δ15N values in urine require more time to reach the new equilibrium, whereas the milk samples show no significant differences between the two feeding regimes.
The application of metrology in chemical analysis is today hampered by psychological and practical barriers. The argumentation is based on the differences in physical and chemical metrology, which arises mainly from the objects of the measurements. The term measurement is discussed in the realm of analytical chemistry with a special focus on the inherent relation between chemical identification and determination as well as the consequent use of the concept of traceability and uncertainty.
Considerations with regard to the calculation of key comparison reference values and uncertainties
(2009)
Much has been published over the last years on finding the best (consensus) reference value for a given set of key comparison data, and a suite of approaches proposed. In this paper, several aspects are highlighted which should be taken into account when deciding on key comparison strategies, protocols, and the best approach to reliable key comparison reference value and uncertainty. Some of these aspects are briefly discussed. The paper is intended to intensify discussions, and any comments and opinions are welcome.
Crystallization processes under different conditions are of fundamental interest in chemistry, pharmacy, and medicine. Therefore, we have studied the formation of micro- and nanosized crystals using water-caffeine (1,3,7-trimethyl-1H-purine-2,6(3H,7H)-dione) solutions under ambient conditions as a relevant model system. When droplets of an aqueous caffeine solution evaporate and eventually dry on surfaces (glass, polystyrene, and polyester), stable coffee tabletop rings with a perimeter of typically 3 mm are formed after 20 to 50 min. Using a micro focus X-ray beam available at the BESSY µSpot-beamline, the fine structure of different caffeine needles can be distinguished. Unexpectedly, both crystal modifications (α- and β-caffeine) are present, but locally separated in these rings. Furthermore, AFM studies reveal the presence of even smaller particles on a nanometer length scale. To eliminate influences of surface irregularities from the crystallization process, acoustic levitation of liquid samples was employed. Such levitated droplets are trapped in a stable position and only surrounded by air. The solvent in an ultrasonically levitated drop evaporates completely, and the resulting crystallization of caffeine was followed in situ by synchrotron X-ray diffraction. In this case, the diffraction pattern is in accordance with pure α-caffeine and does not indicate the formation of the room temperature polymorph β-caffeine. Hence, our investigations open new vistas that may lead to a controlled formation of cocrystals and novel polymorphs of micro- and nanocrystalline materials, which are of relevance for fundamental studies as well as for pharmaceutical and medical applications.
Raman microscopy allows a non-destructive characterisation of inorganic and organic painting materials such as pigments and organic dyestuffs. The objectives of this study are the more recent organic pigments typically present in paintings and other art works from the 20th century. More than 20 organic synthetic pigments from different chemical classes could be identified by Raman spectroscopy using different excitation wavelengths (457.9, 476.5, 487.9, 514.5, 632.8, and 1064 nm). To evaluate the performance for real paint samples, varying paint mixtures of the Hansa Yellow pigment PY 3 and the binding medium Mowilith, a polyvinyl acetate (PVAC) compound, were characterised; PY 3 was determined at a 1 wt% level in the binder. In addition, commercial tube paints containing the quinacridone violet PV 19 were studied. The pigment was clearly identified in all of these more complex oil and acrylic paints. Finally, alizarin (PR 83) and a green copper phthalocyanine pigment (PG 7) could unambiguously be identified by Raman microscopy in the painting Woman with mandolin in yellow and red of Max Beckmann dating 1950. The discovery of a red naphthol AS pigment by Raman spectroscopy in a sample from the Three field workers by Georg Baselitz (1964/1965) demonstrated that in some cases complementary chromatographic methods are needed for a comprehensive identification of the organic pigments.
In this work, we report on the application of hyphenated gas source mass spectrometry to study and understand the mechanism of the reduction-distillation of ZnO using Al powder as reductant in its activated and inactivated form. The experiments revealed that the purity of the Zn metal produced were superior using activated Al with respect to inactivated Al, i.e., m5N8 (99.9998% metallic based) versus m5N3. The achieved purity levels of Zn and the absence of high volatile Cd, Mg, and Sb impurities in the gas phase and the material collected were explained with respect to the impurity elements free-energy values, vapor pressure data, and an observed scavenging effect of the Ta crucible, which was supported by the on-line observed mass spectrometric profiles of the residual gas.
Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated.
Raman signatures of the carotenoid component are studied in individual pollen grains from different species of trees. The information is obtained as differences in the strong pre-resonant Raman spectra measured before and after photodepletion of the carotenoid molecules. The results provide the first in situ evidence of interspecies differences in pollen carotenoid content, structure, and/or assembly between plant species without prior purification. The analysis of carotenoids in situ is confirmed by high-performance thin-layer chromatography (HPTLC)-supported resonance Raman data measured directly on the HPTLC plates after separation of carotenoids in pollen extracts. Utilization of the in situ, extraction-free procedure in carotenoid analysis will improve sensitivity and structural selectivity and provides insight into carotenoid structure and composition in single pollen grains.
Raman and laser-induced breakdown spectroscopy is integrated into a single system for molecular and elemental microanalyses. Both analyses are performed on the same ~ 0.002 mm² sample spot allowing the assessment of sample heterogeneity on a micrometric scale through mapping and scanning. The core of the spectrometer system is a novel high resolution dual arm Echelle spectrograph utilized for both techniques. In contrast to scanning Raman spectroscopy systems, the Echelle-Raman spectrograph provides a high resolution spectrum in a broad spectral range of 200-6000 cm- 1 without moving the dispersive element. The system displays comparable or better sensitivity and spectral resolution in comparison to a state-of-the-art scanning Raman microscope and allows short analysis times for both Raman and laser induced breakdown spectroscopy. The laser-induced breakdown spectroscopy performance of the system is characterized by ppm detection limits, high spectral resolving power (15,000), and broad spectral range (290-945 nm). The capability of the system is demonstrated with the mapping of heterogeneous mineral samples and layer by layer analysis of pigments revealing the advantages of combining the techniques in a single unified set-up.
Ultra high purity Zn (m6N5) was obtained through triple vacuum distillation using an m4N5 Zn as input material. High-volatile impurities were removed from the zinc matrix by vacuum evaporation, while traces having lower volatility than the matrix remained in the residual material after finishing of the entire purification process. The time required for the removal of the main high-volatile impurity (Cd) was monitored using a connected gas source mass spectrometer. During distillation the Zn vapor of the distillate was condensed on the cap of a glassy carbon crucible which was water cooled by a movable copper block. The temperatures were optimized for the removal of the volatiles and for the distillation process using vapor pressure data. High resolution glow discharge mass spectrometry was applied for the analysis and purity evaluation of the distilled and input zinc. The analysis confirmed the reduction of the metallic impurities from 43 mg kg-1 to 0.5 mg kg-1 (m6N5) after three consecutive vacuum distillations. An increase in the grain size and a decrease in the micro-hardness were observed for the purified Zn material.
An efficient solid phase extraction (SPE) method using bis-(2-ethylhexyl)-phosphate (HDEHP) coated reverse phase C18 support has been developed for the pre-concentration of Gadolinium (Gd) and Gd contrast agents widely used in magnetic resonance imaging (MRI). Enrichment of Gd in the ionic form has been compared with strong cation exchange material Chromabond SA (SCX), weak ion exchange material Chelex-100 and also with lanthanide specific HDEHP modified reverse phase C18. The determination of Gd and its complexes after enrichment were performed using inductively coupled plasma mass spectrometry (ICP-MS) and on the basis of 158Gd. Among the three SPE materials, HDEHP coated reverse phase C18 SPE has been found to be most efficient, yielding a hundredfold Gd enrichment with > 95% recovery for linear and cyclic contrast agents like Gd-DTPA (Magnevist), Gd-DOTA (Dotarem), Gd-BOPTA (Multihance), and Gd-BT-DO3A (Gadovist). The developed SPE method has been successfully applied to the surface water and waste water samples originated from different places in Berlin, Germany. The results were in good agreement with the results obtained with direct measurement with ICP-MS. The developed pre-concentration method can be efficiently used for the determination of trace levels of gadolinium in the environment even with less sensitive analytical techniques.
We report herein the utilization of a vacuum reduction distillation system (VRDS) coupled with mass spectrometry (MS) to characterize chemical transformations in thermal analysis. The system initially designed to monitor metal purification by distillation is applied for the first time to the catalytic reaction of in situ formed nickel oxide during the carbothermic reduction of zinc oxide.
Synthetic pressed metal powder standards doped with standard solutions were used for the calibration of both commercially available high resolution GD-MS instruments Element GD and VG 9000 for zinc matrix. Different quantification procedures (IBR, Standard RSF, matrix matched RSF from the calibration with CRMs and use of doped synthetic standards) are compared using zinc matrix as an example, whereas the calibration with doped pellets turned out to be the best quantification technique for high-purity materials. The applicability of the Standard RSF concept is scrutinised. In this context, RSF values for several Matrices (Co, Cu, Fe, In and Zn) are reported additionally.
Detection and monitoring of volatile elements released during the preparation of ultra high purity zinc by vacuum distillation (VD) is reported using online quadrupole gas source mass spectrometry (QMS). The theoretically calculated vapour pressures (pv) for the volatile impurity elements using Dushman constants and the practically observed mass spectra were found to be consistent (S. Dushman and J. M. Lafferty, Scienific Foundations of Vacuum Technique, 2nd ed., Wiley, New York, 1962). This is the first time that the potential ability of an online mass spectrometer was used for monitoring and understanding the process mechanism during the purification of metals (Zn) using VD. We here also illustrate our findings with the results from high resolution glow discharge mass spectrometer (HR-GDMS) analysis before and after the purification of Zn.
The hollow cathode (HC) effect was investigated in non-cooled 15 mm deep drilled flat metallic analytical samples that were easy to prepare. The deep cavity used ("complete HC" in contrast to "recessed HC" with 2-3 mm deep cavity) intensified the HC effect notably and therefore distinctly improved the detection power of the common GD-OES with planar cathodes. A signal enhancement of up to a factor of 150, not reported earlier, in comparison with flat conventional samples was achieved. A better separation of the analytical lines from spectral interferences was observed when the HC assembly was applied. Additionally, an effect of strongly enhanced intensities of atomic lines and somewhat decreased intensities of ionic lines was detected in the case of HC in comparison to usual planar cathodes. The investigations were carried out with samples of copper, steel and zinc matrices using both the same and individually optimised glow discharge (GD) electrical parameters.
The purpose of this work is to improve the performance of a linear correlation method used for material identification in laser induced breakdown spectroscopy. The improved correlation procedure is proposed based on the selection and use of only essential spectral information and ignoring empty spectral fragments. The method is tested on glass samples of forensic interest. The 100% identification capability of the new method is demonstrated in contrast to the traditional approach where the identification rate falls below 100% for many samples.
Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody
(2009)
The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods.
Mass spectrometric detection can play a prominent role in the assessment of different reactions occurring at varied temperatures in a milled ZnO/Al mixture. This is the first time that online mass spectrometric information was used as a tool for monitoring and understanding the chemical reduction process mechanism. We have observed four different types of reaction taking place: (1) distillation of Zn metal, (2) reduction of ZnO by activated Al, (3) melting of Al and finally (4) reduction of ZnO by inactivated Al. The experimental conditions and results observed by QMS were supported with literature data and physical measurement data from X-Ray Diffraction (XRD) which gave us an idea about the complex reaction cascade which occurred during the formation of the zinc metal.
In this study, an analytical procedure for multi-element screening of 40 elements in milk and feed samples was developed. Three different digestion and two different calibration methods were tested for the best suitability. The analytical procedure for the quantification of minor and trace elements is based on sector field ICP-MS (SF-ICP-MS). The method validation revealed good agreement between the determined elemental mass fractions and the certified values of two milk and three feed reference materials. Milk samples of dairy cows at different feeding regimes were collected from two different farms. The results of our study showed significant differences of nine elemental mass fractions (Li, P, Mn, Co, Cu, Rb, Sr, Br, I) between milk from the two locations. Further, a correlation between the elemental mass fractions of milk and the ingested feed and water was observed.
We report on the in situ characterization of tree pollen molecular composition based on Raman spectroscopy. Different from purification-based analysis, the nondestructive approach allows (i) to analyze various classes of molecules simultaneously at microscopic resolution and (ii) to acquire fingerprint-like chemical information that was used for the classification of pollen from different species. Hierarchical cluster analysis of spectra from fresh pollen samples of 15 species partly related at the genus level and family level indicates separation of species based on the complete Raman spectral signature and yields classification in accord with biological systematics. The results have implications for the further elucidation of pollen biochemistry and also for the development of chemistry-based online pollen identification methods.
Nanoaggregates formed by metal spheres of different radii and interparticle distances represent finite, deterministic, self-similar systems that efficiently concentrate optical fields and act as nanolenses. Here we verify experimentally the theoretical concept of nanolenses and explore their potential as enhancing nanostructures in surface enhanced Raman scattering (SERS). Self-similar structures formed by gold nanospheres of different sizes are generated by laser ablation from solid gold into water. These nanolenses exhibit SERS enhancement factors on the order of 109. The chemically clean preparation process provides several advantages over chemically prepared nanoaggregates and makes the stable and biocompatible gold nanolenses potent enhancing structures for various analytical and sensing applications.
Determination of the efficiency of an energy dispersive X-ray spectrometer up to 50 keV with a SEM
(2009)
Both electron and polychromatic photon excitations (micro-focus X-ray source) at a scanning electron microscope (SEM) are used to determine the efficiency of an energy dispersive X-ray spectrometer up to 50 keV by means of a calibrated X-ray spectrometer and reference materials (RM) specially selected for this purpose.
Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions.
In Germany a system of primary amount of substance standards for elemental analysis is being developed, which forms the material´s basis for the National Standards for element determination. The metrological concept and technical approach is briefly described. The objective of traceability in chemistry, in this case for elemental determination, is illustrated on the example of copper.
In this work, different calibration strategies for the determination of trace elements in pure copper metal by nanosecond laser ablation ICP-MS were investigated. In addition to certified reference materials (CRMs), pellets of doped copper powder were used for calibration. The micro homogeneity of the CRMs as well as the solution-doped pellets was sufficient to use them as calibration samples in combination with a laser spot size of 200 µm. In contrast, pellets doped with analytes in solid form showed a significant heterogeneity. For most of the investigated analytes and copper CRMs the measured mass fractions were within ± 20% of their certified values when other copper CRMs were used as calibration samples. When solution-doped powder pellets were used as calibration samples a systematic trend towards mass fractions below the certified values was observed for nearly all elements determined in the analysed CRMs. Thermal fractionation effects during the ablation of the solution-doped pellets were suspected as the extent of the fractionation depends on the irradiance, whereas fractionation is reduced at higher irradiance.
A combination of two analytical methods, time-resolved X-ray diffraction (XRD) and Raman spectroscopy, is presented as a novel tool for crystallization studies. An acoustic levitator was employed as sample environment. This setup enables the acquisition of XRD and Raman data in situ simultaneously within a 20 s period and hence permits investigation of polymorphic phase transitions during the crystallization process in different solvents (methanol, ethanol, acetone, dichloromethane, acetonitrile). These real time measurements allow the determination of the phase content from the onset of the first crystalline molecular assemblies to the stable system. To evaluate the capability of this approach, the setup was applied to elucidate the crystallization process of the polymorphic compound nifedipine. The results indicate the existence of solvent-dependent transient phases during the crystallization process. The quality of the data allowed the assignment of the lattice constants of the hitherto unknown crystal structure of the β-polymorph.
The chemical characterization and discrimination of allergy-relevant pollen (common ragweed (Ambrosia artemisiifolia), white birch (Betula pendula), English oak (Quercus robur), and European linden (Tilia cordata)) has been studied by Raman microscopy. Spectra were obtained at different excitation wavelengths (514, 633, and 780 nm) and various methods were examined to minimize the strong fluorescence background. The use of a HeNe laser (633 nm) for excitation yields high-quality single pollen Raman spectra, which contain multiple bands due to pollen components such as carotenoids, proteins, nucleic acids, carbohydrates, and lipids. Multivariate classification, i.e. principal component analysis (PCA) and hierarchical cluster analysis, demonstrated the validity of the approach for discrimination between different pollen species.
ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment.
An immunoassay was developed for ochratoxin A (OTA) detection in wine and two completely different detection methods were compared: ICP-MS and photometry. For labelling, we applied secondary antibodies conjugated with gold nanoparticles for ICP-MS and with horseradish peroxidase for photometric detection, respectively. Detection limits of the assay were determined as 0.003 µg L-1 for both detection methods. OTA in wine was determined below the EU limit value of 2 µg kg-1. The measurement range was between 0.01 and 1 µg L-1 for ICP-MS and photometric detection. Assay precision detected by ICP-MS and photometry were similar showing that precision of the detection method has only a minor effect on total assay precision. By using BSA as a buffer additive to minimize nonspecific binding, we could also confirm that OTA strongly binds to BSA. In a comparison study of several additives, casein was found to be preferable.
Deciphering the sulfate attack of cementitious materials by high-resolution micro-x-ray diffraction
(2011)
The durability of cementitious materials depends, among others, on their resistance against chemical attack during the service life of a building. Here, we present an approach to analyze changes in the phase composition due to chemical attack in the form of sulfate ingress within the microstructure. Micro-X-ray (µX-ray) diffraction using synchrotron radiation in Debye–Scherrer (transmission) geometry allowed a spatial resolution of 10 µm. Phase transformations in the wake of damaging processes were observed in a detailed high-resolution imaging study. In comparison, samples containing supplementary cementitious materials were investigated and used to reconstruct the influence of different degeneration processes in detail. Additionally, reaction fronts within the bulk were localized by micro-X-ray fluorescence analysis. The experimental setup provided the possibility for analyzing the phase assemblage of a given sample without destroying the microstructure. The specimens for phase analysis are thick sections of the primary material and can be used for further microscopic analysis of the microstructure and microchemistry, e.g., scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM–EDX) or Raman spectroscopy.
Molecular masses and end groups of polystyrene (PS) formed in a novel container-less polymerization strategy, based on levitated droplets in an acoustic trap, were determined by Gel Permeation Chromatography (GPC) and Matrix-assisted Laser Desorption/Ionization Time of Flight Mass spectrometry (MALDI-TOF MS).
The potential of a diode pumped solid state (DPSS) laser for laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy was investigated. The DPSS laser operating at repetition rates of 1 Hz–200 kHz, pulse energy of ~1 mJ, and pulse duration of ~20 ns was added to a conventional LIBS system equipped with the flashlamp-pumped Nd:YAG laser (10 Hz, 400 mJ, 6 ns) to directly compare the two laser systems. Despite the lower mass ablated per laser pulse (~several nanograms) and a weaker plasma, the total mass ablated per measurement interval (~1 s) and total emission signal were significantly higher than those obtained with the flashlamp pumped Nd:YAG laser. This resulted in the improved signal-to-noise ratio and better limits of detection (LOD). The best LODs were obtained for Cu, Cr and Ni in ultrapure standard iron samples, 0.7 ppm, 1 ppm and 5 ppm, correspondingly. The plasma from the DPSS laser was characterized in terms of its radiative properties, temperature, and shockwave propagation speed. The suitability of this laser for LIBS-Raman was demonstrated by mapping the elemental and molecular composition of a mineral sample. The results strongly imply that DPSS lasers are the promising source for LIBS, Raman, or combined LIBS-Raman spectroscopy.
In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl2F2 as gaseous halogenation modifier was investigated. Especially for the carbide forming elements the sensitivity was improved and the memory effects were significantly reduced. Calibration was performed by external calibration and standard addition with aqueous standard solutions added directly into the sample boats. Absolute limits of detection (3s-criterion) range between 0.1 ng (Cd) and 9 ng (Fe) which corresponds to relative values of 0.1 mg kg-1 and 1.6 mg kg-1, respectively, taking 5 mg as typical sample mass. The detection limits are sufficient to monitor the element contents of plastic materials according to European directives such as European directive on the safety of toys. The developed ETV-ICP-OES method allows a fast analysis with a high sample throughput (3 minutes per analysis), low sample consumption and good trueness and precision for the analyzed elements. Sample preparation is reduced to ashing the samples in a muffle furnace. Furthermore, measurements are possible regardless of the chemical form in the additives. For verification the results obtained with the developed method were compared with measurement results of independent methods ICP-MS/OES after digestion. In addition Cd, Cr and Pb were determined in a solid plastic reference material BAM-H010 to confirm the applicability and accuracy of the method.
The segregation in dried droplet MALDI sample spots was analyzed with regard to the matrix-to-sample ratio using optical microscopy, MALDI imaging mass spectrometry (MALDI MSI) and IR imaging spectroscopy. In this context, different polymer/matrix/solvent systems usually applied in the analysis of synthetic polymers were investigated. The use of typical matrix concentrations (10 mg mL-1) in almost every case resulted in ring patterns, whereas higher concentrated matrix solutions always led to homogeneous sample spot layers. The data revealed that segregation is predominantly caused by matrix transport in the drying droplet, whereas polymer segregation seems to be only secondary.
High repetition rate laser-induced breakdown spectroscopy using acousto-optically gated detection
(2014)
This contribution introduces a new type of setup for fast sample analysis using laser-induced breakdown spectroscopy (LIBS). The novel design combines a high repetition rate laser (up to 50 kHz) as excitation source and an acousto-optical modulator (AOM) as a fast switch for temporally gating the detection of the emitted light. The plasma radiation is led through the active medium of the AOM where it is diffracted on the transient ultrasonic Bragg grid. The diffracted radiation is detected by a compact Czerny-Turner spectrometer equipped with a CCD line detector. Utilizing the new combination of high repetition rate lasers and AOM gated detection, rapid measurements with total integration times of only 10 ms resulted in a limit of detection (LOD) of 0.13 wt.% for magnesium in aluminum alloys. This short integration time corresponds to 100 analyses/s. Temporal gating of LIP radiation results in improved LODs and consecutively higher sensitivity of the LIBS setup. Therefore, an AOM could be beneficially utilized to temporally detect plasmas induced by high repetition rate lasers. The AOM in combination with miniaturized Czerny-Turner spectrometers equipped with CCD line detectors and small footprint diode pumped solid state lasers results in temporally gateable compact LIBS setups.
Hydrophilic interaction chromatography (HILIC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) were optimised for the direct determination of gadolinium-based contrast agents in tap water. In comparison to our previous work, a new developed zwitterionic HILIC column (ZIC-cHILIC) was used for speciation of Gd-containing contrast agents. The limit of quantification (LOQ) for the five contrast agents Gd-BOPTA, Gd-DPTA-BMA, Gd-BT-DO3A, Gd-DOTA and Gd-DTPA are in the range of 512 ng Gd per litre. Additionally, a new internal standard, Pr-DOTA, was investigated to correct intensity drifts, minor and major changes in the sample volumes and possible matrix effects. With the speciation method described, tap water samples from the area of Berlin were analysed and for the first time, three Gd species, Gd-BT-DO3A, Gd-DOTA and Gd-BOPTA, were found in tap water samples at concentrations of about 10–20 ng Gd per litre. These are the same Gd species which have been previously detected predominantly in surface waters of the Berlin area.
Pathway of a damaging mechanism - Analyzing chloride attack by synchrotron based X-ray diffraction
(2015)
Typically, the changes of the phase compositions due to the chemical attack are studied in-situ only by chemical analysis or microscopy. In this study, the chloride transport and binding in the cement matrix in different cementitious materials was analyzed by synchrotron based X-ray diffraction (SyXRD) and energy dispersive X-ray spectroscopy (EDX). Sample materials consisting of cement paste were embedded in high concentrated sodium chloride solution over different time spans. Afterwards, the phase and chemical compositions were determined. The high spatial resolution and the information about the chloride distribution offer a detailed view of chloride binding in the cement matrix and allow the conclusions about the degradation mechanisms. The results are discussed related to the influence of different supplementary cementitious materials on the damaging mechanism.
Rationale
The ionization of polystyrenes in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is typically achieved by the use of silver salts. Since silver salts can cause severe problems, such as cluster formation, fragmentation of polymer chains and end group cleavage, their substitution by alkali salts is highly desirable.
Methods
The influence of various cations (Ag+, Cs+ and Rb+) on the MALDI process of polystyrene (PS) mixtures and high mass polystyrenes was examined. The sample preparation was kept as straightforward as possible. Consequently, no recrystallization or other cleaning procedures were applied.
Results
The investigation of a polystyrene mixture showed that higher molecular polystyrenes could be more easily ionized using caesium, rather than rubidium or silver salts. In combination with the use of DCTB as matrix a high-mass polymer analysis could be achieved, which was demonstrated by the detection of a 1.1 MDa PS.
Conclusions
A fast, simple and robust MALDI sample preparation method for the analysis of ultra-high molecular weight polystyrenes based on the use of DCTB and caesium salts has been presented. The suitability of the presented method has been validated by using different mass spectrometers and detectors.
Spatially resolved analysis of complex multi-phase systems can be validated through different analytical methods. This study compares investigations by scanning electron microscopy coupled with energy dispersive X-ray fluorescence analysis and high resolution X-ray diffraction. The studied sulfate attacked cement paste containing fly ashes consists of different interacting crystalline and amorphous phases. The complementary methods revealed in detail changes in phase composition due to the chemical attack. The advantages and disadvantages of both methods are discussed and suggestions are given for combining them with additional methods to maximize the information content.
A micro-droplet generator (µDG) sample introduction system was coupled to a sector field ICP-MS instrument to investigate the analytical figures of merit with respect to single cell analysis. The sector field instrument was operated for the first time in a fast scanning mode (E-scan) with the shortest time resolution of 100 µs to measure the single droplet time resolved and using the original detector in a pulse counting mode without modification of the existing electronics. For reduction of the droplet diameter a triple pulse mode of the droplet generator was applied and a droplet diameter down to 23 µm has been achieved for this investigation with a 100% transport efficiency of droplets. Signal duration times of single droplets of less than 500 µs have been measured. Overall detection efficiencies in the range of 10-3 counts per atom have been achieved and absolute limits of detection range between 120 ag for Fe and 1.1 ag for Mg as a mean value from 1000 droplet events.
We have applied a micro droplet generator (µDG) for sample introduction of single selenized yeast cells into a sector field ICP-MS, which was operated in a fast scanning mode with sampling rates of up to 10 kHz, to measure single cells time resolved with 100 µs integration time. Selenized yeast cells have been used as a model system for preliminary investigation. The single cells to be measured have been embedded into droplets and it will be shown that the time duration of a single cell event always is about 400 to 500 µs, and thus comparable to the time duration of a droplet without a cell. A fixed droplet generation rate of 50 Hz produced equidistant signals in time of each droplet event and was advantageous to separate contribution from background and blank from the analytical signal. Open vessel digestion and a multielement analysis were performed with washed yeast cells and absolute amounts per single cell were determined for Na (0.91 fg), Mg (9.4 fg), Fe (5.9 fg), Cu (0.54 fg), Zn (1.2 fg) and Se (72 fg). Signal intensities from single cells have been measured for the elements Cu, Zn and Se, and histograms were calculated for about 1000 cell events. The mean elemental sensitivities measured here range from 0.7 counts per ag (Se) to 10 counts per ag (Zn) with RSD's from 49% (Zn) to 69% (Se) for about 1000 cell events.
In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study.
This paper presents a numerical and an experimental procedure to obtain the pressure field in single-axis acoustic levitators. Numerically, the pressure field is determined by a matrix method based on the Rayleigh integral that take into account the multiple wave reflections that occur between the transducer and the reflector. The numerical pressure field is compared with the acoustic pressure measured by an earplug microphone, that is connected to a hollow needle. The tip of the needle is moved by a µm translation stage through the field and the signal is recorded using a lock-in amplifier locked to the levitator frequency. The pressure field obtained numerically show good agreement with that obtained experimentally.
In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis.
The improved Monte-Carlo (MC) method for standard-less analysis in laser induced breakdown spectroscopy (LIBS) is presented. Concentrations in MC LIBS are found by fitting model-generated synthetic spectra to experimental spectra. The current version of MC LIBS is based on the graphic processing unit (GPU) computation and reduces the analysis time down to several seconds per spectrum/sample. The previous version of MC LIBS which was based on the central processing unit (CPU) computation requested unacceptably long analysis times of 10's minutes per spectrum/sample. The reduction of the computational time is achieved through the massively parallel computing on the GPU which embeds thousands of co-processors. It is shown that the number of iterations on the GPU exceeds that on the CPU by a factor > 1000 for the 5-dimentional parameter space and yet requires > 10-fold shorter computational time. The improved GPU-MC LIBS outperforms the CPU-MS LIBS in terms of accuracy, precision, and analysis time. The performance is tested on LIBS-spectra obtained from pelletized powders of metal oxides consisting of CaO, Fe2O3, MgO, and TiO2 that simulated by-products of steel industry, steel slags. It is demonstrated that GPU-based MC LIBS is capable of rapid multi-element analysis with relative error between 1 and 10's percent that is sufficient for industrial applications (e.g. steel slag analysis). The results of the improved GPU-based MC LIBS are positively compared to that of the CPU-based MC LIBS as well as to the results of the standard calibration-free (CF) LIBS based on the Boltzmann plot method.
Statistical ethylene oxide (EO) and propylene oxide (PO) copolymers of different monomer compositions and different average molar masses additionally containing two kinds of end groups (FTD) were investigated by ultra high pressure liquid chromatography under critical conditions (UP-LCCC) combined with electrospray ionization time-of flight mass spectrometry (ESI-TOFMS).
Theoretical predictions of the existence of a critical adsorption point (CPA) for statistical copolymers with a given chemical and sequence distribution1 could be studied and confirmed. A fundamentally new approach to determine these critical conditions in a copolymer, alongside the inevitable chemical composition distribution (CCD), with mass spectrometric detection, is described. The shift of the critical eluent composition with the monomer composition of the polymers was determined. Due to the broad molar mass distribution (MMD) and the presumed existence of different end group functionalities as well as monomer sequence distribution (MSD), Gradient separation only by CCD was not possible. Therefore, isocratic separation conditions at the CPA of definite CCD fractions were developed. Although the various present distributions partly superimposed the separation process, the goal of separation by end group functionality was still achieved on the basis of the additional dimension of ESI-TOF-MS. The existence of HO-H besides the desired allylO-H end group functionalities was confirmed and their amount estimated. Furthermore, indications for a MSD were found by UPLC/MS/MS measurements. This approach offers for the first time the possibility to obtain a fingerprint of a broad distributed statistical copolymer including MMD, FTD, CCD, and MSD.
Single particle ICP-MS (spICP-MS) has gained great influence in the analysis of engineered nanoparticles (NPs) due to its simplicity, speed and ability to obtain a particle number size distribution. Despite its many advantages, the method is hampered by matrix effects affecting the sensitivity of the instruments.
Consequently, over- or underestimated particle sizes might be obtained. To overcome these challenges, we present in this work the detection of both Ag isotopes with a quadrupole mass spectrometer for the application of isotopic dilution analysis (IDA) in combination with spICP-MS. Here, the isotopes are measured sequentially using the conventional spICP-MS integration time of 10 ms. Citrate stabilized Ag NPs of a spherical shape with the nominal diameters of 30, 40, 50 and 80 nm have been investigated.
The experimental concept of adding ¹⁰⁹Ag+ solutions to the NP suspensions resulted in the NP Spikes being only visible in the ¹⁰⁷Ag trace. Therefore, a maximum of 45% of the particles was detected compared to that by conventional spICP-MS. A modified mass flow equation was applied to determine the particle sizes, particle size distributions and particle number concentrations of various Ag NPs. The addition of different spike concentrations between 0.5 and 4 mg L⁻¹ ¹⁰⁹Ag resulted in similar particle diameters, suggesting that the calculated diameter might be independent of the spike concentration.
This would have the advantage that no size information would be needed before the analysis. By analyzing Ag NP suspensions in a simulated seawater matrix, we demonstrate its significant influence on the particle size determination using conventional spICP-MS. A lower transport efficiency of 6.1% was found in the matrix compared to 7.3% without the matrix. In our approach, the addition of the Matrix influenced the NP intensity stronger than the spike signal, resulting in slightly smaller diameters using IDA–spICP-MS with the matrix compared to the results without the matrix. On the other hand, the IDA–spICP-MS approach with the matrix can result in equivalent results for the particle sizes compared with
conventional spICP-MS using suspensions without the matrix. Due to the lower instrument sensitivity in the matrix, a diameter of 30 nm was found to be close to the detection limit of the instrument.
A reversed phase high performance liquid chromatography coupled to an inductively coupled Plasma mass spectrometer (HPLC–ICP-MS) approach in combination with isotope dilution analysis (IDA) for the separation and parallel quantification of nanostructured and ionic silver (Ag) is presented. The main Focus of this work was the determination of the ionic Ag concentration. For a sufficient stabilization of the Ions without dissolving the nanoparticles (NPs), the eluent had to be initially optimized. The determined Ag ion concentration was in a good agreement with results obtained using ultrafiltration. Further, the mechanism of the NP separation in the HPLC column was investigated. Typical size exclusion effects were found by comparing results from columns with different pore sizes. Since the recovery rates decreased with increasing Ag NP size and large Ag NPs did not elute from the column, additional interactions of the particles with the stationary phase were assumed. Our results reveal that the presented method is not only applicable to Ag NPs, but also to gold and polystyrene NPs. Finally, IDA-HPLC-ICP-MS experiments in single particle mode were performed to determine the particle cut-off size. The comparison with conventional spICP-MS experiments resulted in a similar diameter and particle size distribution.
Quantitative NMR spectroscopy for gas analysis for production of primary reference gas mixtures
(2017)
Due to its direct correlation to the number of spins within a sample quantitative NMR spectroscopy (qNMR) is a promising method with absolute comparison abilities in complex systems in technical, as well as metrological applications. Most of the samples studied with qNMR are in liquid state in diluted solutions, while gas-phase applications represent a rarely applied case. Commercially available NMR equipment was used for purity assessment of liquid and liquefied hydrocarbons serving as raw materials for production of primary reference gas standards. Additionally, gas-phase studies were performed within an online NMR flow probe, as well as in a high-pressure NMR setup to check feasibility as verification method for the composition of gas mixtures.
The catalytic efficiency of two magnetically responsive nanocatalysts was evaluated for the Degradation of Reactive Black 5 (RB5) and Reactive Yellow 84 (RY84) azo dyes using hydrogen peroxide as oxidant undervery mild conditions (atmospheric pressure, room temperature). In order to obtain the nanocatalysts, thesurface of magnetite (Fe3O4) nanoparticles, prepared by a co-precipitation method, was further modified with ferrous oxalate, a highly sensitive non-hazardous reducing agent. The sensitized nanomaterials were characterized by X-ray diffraction, scanning and transmission electron microscopy, energy-dispersive X-ray spectroscopy and vibrating sample magnetometry, and used in the catalytic wet hydrogen peroxideoxidation (CWHPO) of RB5 and RY84, in laboratory-scale experiments. The effect of important variables such as catalyst dosage, H2O2 concentration, and contact time was studied in the dye Degradation kinetics. The results showed that it was possible to remove up to 99.7% dye in the presence of 20 mM H2O2 after 240 min of oxidation for a catalyst concentration of 10 g L−1at 25◦C and initial pH value of 9.0.CWHPO of reactive dyes using sensitized magnetic nanocatalysts can be a suitable pre-treatment methodfor complete decolorization of effluents from textile dyeing and finishing processes, once the Optimum operating conditions are established.
The use of magnetic materials as heterogeneous catalysts has attracted increasing attention in the last years since they proved to be promising candidates for water treatment. In the present study, two types of surface-modified magnetite (Fe3O4) nanoparticles, coated with non-hazardous naturally occurring agents—either tannic acid (TA) or dissolved natural organic matter—were evaluated as magnetic heterogeneous catalysts. Chemical synthesis (co-precipitation) was chosen to yield the nanocatalysts due to its well-established simplicity and efficiency. Subsequently, the properties of the final products were fully assessed by various characterization techniques. The catalytic activity in heterogeneous oxidation of aqueous solutions containing a model pollutant, Bisphenol A (BPA), was comparatively studied. The effect of operational parameters (catalyst loading, H2O2 dosage, and UV light irradiation) on the Degradation performance of the oxidation process was investigated. The optimum experimental parameters were found to be 1.0 g/L of catalysts and 10 mM H2O2, under UV irradiation. The highest mineralization rates were observed for Fe3O4-TA catalyst. More than 80 % of BPA was removed after 30 min of reaction time under the specified experimental conditions. The obtained results showed that the two catalysts studied here are suitable candidates for the removal of pollutants in wastewaters by means of heterogeneous reaction using a green sustainable treatment method.
This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6 ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Crossreactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1 cm2 of one banknote by swabbing 1 cm2: 0, 14, and 21 pg/cm2. Moreover, three notes of different denominations revealed high cocaine concentration; 1.1 mg/note, and twice 55 μg/note.
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of 1H spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibrationfree approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h-1 at 25 °C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance.
Boron isotope amount ratios n(10B)/n(11B) have been determined by monitoring the absorption spectrum of boron monohydride (BH) in a graphite furnace using high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Bands (0→0) and (1→1) for the electronic transition X1Σ+ → A1Π were evaluated around wavelengths 433.1 nm and 437.1 nm respectively. Clean and free of memory effect molecular spectra of BH were recorded. In order to eliminate the memory effect of boron, a combination of 2% (v/v) hydrogen gas in argon and 1% trifluoromethane in argon, an acid solution of calcium chloride and mannitol as chemical modifiers was used. Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression was built. Results obtained around the 433.1 nm and 437.1 nm spectral regions are metrologically compatible with those reported by mass spectrometric methods. Moreover, for the evaluated region of 437 nm, an accuracy of 0.15‰ is obtained as the average deviation from the isotope reference materials. Expanded uncertainties with a coverage factor of k = 2 range between 0.15 and 0.44‰. This accuracy and precision are compatible with those obtained by mass spectrometry for boron isotope ratio measurements.
The release of iron from iron nanoparticles (NPs) used as parenteral formulations appears to be influenced by the size and surface properties of the colloidal iron complex and the matrix. A clinically applied product Venofer® has been used as a model formulation to establish adequate analytical strategies to evaluate the fate of iron nanoparticles (NPs) in blood. First, the preparation was characterized by high resolution transmission electron microscopy (HRTEM), dynamic light scattering (DLS) and UV-vis absorption spectroscopy. This revealed the presence of monodisperse iron NPs with a hydrodynamic diameter of ∼15 nm and an iron core of ∼4 nm. Venofer® was then incubated with serum and whole blood in a quantitative study on the iron bioavailability from these NPs. Iron was speciated and quantified by using inductively coupled plasma mass spectrometry (ICP-MS). Iron solubilization levels of up to 42% were found in both fluids using isotope dilution of iron for quantification within the first hour of incubation even in the absence of the reticuloendothelial system. The monitoring of the iron-containing proteins present in serum was conducted by highperformance liquid chromatography with ICP-MS detection. It indicated that the dissolved iron ions are bound to transferrin. Quantitative speciation studies using isotope pattern deconvolution experiments concluded that the released iron saturated almost completely (up to 90%) the metal binding sites of transferrin. The remaining iron appeared also associated to albumin and, to a lesser extent, forming smaller sized particles. Thus, the methods presented here provide new insights into the fate of Venofer® nanoparticles and may be applied to other formulations.
Cost-effective water cleaning approaches using improved Treatment technologies, for instance based on catalytic processes with high activity catalysts, are urgently needed. The aim of our study was to synthesize efficient Fenton-like photo-catalysts for rapid degradation of persistent organic micropollutants in aqueous medium. Iron-based nanomaterials were chemically synthesized through simple procedures by immobilization of either iron(II) oxalate (FeO) or iron(III) citrate (FeC) on magnetite (M) nanoparticles stabilized with polyethylene glycol (PEG). Various investigation techniques were performed in order to characterize the freshly prepared catalysts. By applying advanced oxidation processes, the effect of catalyst dosage, hydrogen peroxide concentration and UV-A light exposure were examined for Bisphenol A (BPA) conversion, at laboratory scale, in mild conditions. The obtained results revealed that BPA degradation was rapidly enhanced in the presence of low-concentration H2O2, as well as under UV-A light, and is highly dependent on the surface characteristics of the catalyst. Complete photo-degradation of BPA was achieved over the M/PEG/FeO catalyst in less than 15 minutes. Based on the catalytic performance, a hierarchy of the tested catalysts was established: M/PEG/FeO > M/PEG/FeC > M/PEG. The results of cytotoxicity assay using MCF-7 cells indicated that the aqueous samples after treatment are less cytotoxic.
Previously applied methods for the quantification of sulphur in copper and other pure metals revealed a lack of SI-traceability and additionally showed inconsistent results, when different methods were compared.
Therefore, a reference procedure is required which allows SI-traceable values accompanied by a Sound uncertainty budget. In this study a procedure was developed for the quantification of total sulphur in copper at low concentration levels using inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS). The major part of the copper matrix was separated by adding ammonia which forms a complex with the copper while releasing the sulphur followed by chromatographic separation using a weak cation resin. After that the sulphur fraction was further purified by chromatographic means using first an anion exchange method and second a chelating resin. The developed procedure shows high performance, especially concerning high efficiency in matrix removal (>99.999%) while keeping the recovery of sulphur above 80%. Procedure blanks are in the order of 3–53 ng resulting in LOD and LOQ values of 0.2 mg g1 and 0.54 mg g1, respectively. The procedure is sufficient to facilitate value assignment of the total sulphur mass fraction in reference materials. Additionally, relative measurement uncertainties were calculated to be below 1% and the measurement results were traceable to the SI. The procedure reported in this study is a new reference procedure for sulphur measurement in copper, being fit for two major purposes, certification of reference materials and assignment of reference values for inter-laboratory comparison.
Optical elemental analysis in the gas phase typically relies on electrically driven plasmas. As an alternative approach, laser-induced plasmas (LIPs) have been suggested but have so far been only scarcely used.
Here, a novel signal enhancement strategy for laser-based airborne plasma optical Emission spectroscopy for gas phase analytics is presented. In contrast to an electrically driven plasma, in the laser-induced analogue dynamic matter transport equilibrium builds up. The latter results in a rarefied density regime in the plasma core itself, surrounded by an area of compressed matter. The central rarefaction leads to a decrease in plasma intensity and analyte number density, both of which are detrimental for analytical purposes. Since the repetitive ignition of LIPs is a transient process, a restoration of the former gaseous medium by other dynamically equilibrated diffusion processes would be favourable. The presented combination of an airborne LIP and an ultrasonic acoustic resonator yields a fourfold signal enhancement while the Background contribution of ubiquitous air is at the same time effectively suppressed. Since the entire enhancement effect occurs without contact, no additional sources for abrasive sample contamination are introduced.
Biotransformation processes of fluopyram (FLP), a new succinate dehydrogenase inhibitor (SDHI) fungicide, were investigated by electrochemistry (EC) coupled online to liquid chromatography (LC) and electrospray mass spectrometry (ESI-MS). Oxidative phase I metabolite production was achieved using an electrochemical flow-through cell equipped with a boron doped diamond (BDD) electrode. Structural elucidation and prediction of oxidative metabolism pathways were assured by retention time, isotopic patterns, fragmentation, and accurate mass measurements using EC/LC/MS, LC-MS/MS, and/or high resolution mass spectrometry (HRMS). The results obtained by EC were compared with conventional in vitro studies by incubating FLP with rat and human liver microsomes (RLM, HLM). Known phase I metabolites of FLP (benzamide, benzoic acid, 7-hydroxyl, 8-hydroxyl, 7,8-dihydroxyl FLP, lactam FLP, pyridyl acetic acid, and Z/E-olefin FLP) were successfully simulated by EC/LC/MS. New metabolites including an imide, hydroxyl lactam, and 7-hydroxyl pyridyl acetic acid oxidative metabolites were predicted for the first time in our study using EC/LC/MS and liver microsomes. We found oxidation by dechlorination to be one of the major metabolism mechanisms of FLP. Thus, our results revealed that EC/LC/MS-based metabolic elucidation was more advantageous on time and cost of analysis and enabled matrix-free detection with valuable information about the mechanisms and intermediates of metabolism processes.
From simple homopolymers to functionalized, 3-dimensional structured copolymers, the complexity of polymeric materials has become more and more sophisticated. With new applications for instance in the semiconductor or pharmaceutical industry, the requirements for the characterization have risen with the complexity of the used polymers. For each additional distribution, an additional dimension in analysis is needed. Small, often isomeric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector, but affect the properties of materials significantly. For a drug delivery system for example, the degree of branching and branching distribution is crucial for the formation of micelles. Instead of a complicated, time consuming and/or expensive 2d-chromatography or ion mobility spectrometry (IMS) method, that also has its limitations, in this work a simple approach using size exclusion chromatography (SEC) coupled with electrospray ionization mass spectrometry (ESI) is proposed. The online coupling allows the analysis of reconstructed ion chromatograms (RIC) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities. Although some microstructural heterogeneities like short chain branching can for large polymers be characterized with methods such as light scattering, for oligomers where the heterogeneities just start to form and their influence is at the maximum, they are inaccessible with these methods. It is also shown, that with a proper calibration even quantitative information can be obtained. This method is suitable to detect small differences in e. g. branching, 3d-structure, monomer sequence or tacticity and could potentially be used in routine analysis to quickly determine deviations.
Singlet oxygen generation potential of two novel free-base-porphyrin photocatalysts was investigated. The freebase-porphyrin-sensitized Fe3O4 magnetic nanoparticles (MNPs) were tested for the degradation of the model pollutant Bisphenol A (BPA) in aqueous solution, for the first time. MNPs with either cubic or spherical shape were synthesized using the sonochemical approach, followed by sensitizing with photoactive 4,4′,4′′,4′′′- (Porphine-5,10,15,20-tetrayl)tetrakis(benzoic acid) (TCPP). The resulted photocatalysts were characterized in detail by scanning and transmission electron microscopy, Brunauer–Emmett–Teller analysis, spectral techniques and vibrating sample magnetometry. The electron spin resonance experiments have confirmed the high activity of the photocatalysts through the efficient formation of singlet oxygen in solution. The optimum operational parameters for BPA degradation were established as follows: 1.0 μmol L−1 BPA, 1.0 g L−1 of photocatalyst, 100 μmol L−1 H2O2, under UVA irradiation. In these conditions, the results for both photocatalysts revealed that after only 10 min of reaction, over 64% and ca. 90% of BPA have been removed from solution in the absence and presence of H2O2, respectively. Whereas after 60 minutes of treatment, only 24% of BPA in real wastewater effluent samples were removed under UVA irradiation in the absence of H2O2, showing the high complexity of real wastewater. Moreover, both photocatalysts were successfully used for BPA removal in three consecutive runs, without significant loss of catalytic features.
The Radon transform is tested as a method for reconstruction of the emissivity distribution of asymmetric laser induced plasmas. Two types of experiments were carried out. First, the plasma asymmetry is introduced via focusing the laser by a cylindrical lens to create plasma plumes elongated along the symmetry axis of the lens. Second, an asymmetric power distribution across the laser beam is created by reflecting the latter from a damaged mirror. Various effects on the quality of the plasma emissivity reconstructed by the Radon tomography method are investigated. The understanding of these effects appears to be essential to design a proper experimental setup to study LIBS plasmas by the Radon tomography method. It is demonstrated that the Radon tomography can successfully be used for experimental studies of asymmetric LIBS plasmas.
Setting cement: Highly dynamic hydration processes that occur during the first seconds of cement hydration were studied by time-resolved synchrotron X-ray diffraction. Polycarboxylate ether additives were found to influence the formation of the initial crystalline hydration products on a molecular level.
Popular X-ray tube models available in the literature, i.e. 'Pella', 'Ebel', and 'Finkelshtein and Pavlova', are systematically evaluated with the focus on the estimation of the associated uncertainties. Also taken in consideration and compared is our recent semi-empirical own approach already employed in our lab. This has been working for the common target elements rhodium, molybdenum and tungsten and was further extended in the present work for the target elements copper, chromium and vanadium. By using a modern scanning electron microscope/energy dispersive spectroscopy (SEM/EDS) system this time, higher performances such as stability of the beam current and especially the better energy resolution of the EDS have enabled the reliable extension of our own X-ray tube spectrum approach into the low-energy range, due to increasing interest. Hence, also the more challenging X-ray lines of copper, chromium and vanadium L-series lying in the energy range below 12?keV are included into the model. Such low-energy L-lines or, e.g. M-lines of tungsten, are not treated explicitly by the other existing popular algorithms for the nowadays widely used geometries of side-window tubes, offering a unique virtue to our present, modern approach. With our own model, a measurement uncertainty of the X-ray tube spectra (considering the uncertainties associated with the SEM beam current, the detector acceptance solid angle and efficiency of the spectrometer) within 15% has been estimated. The validation of the approach is demonstrated with metrological measurements with a calibrated SEM/EDS system geometrically configured as a side-window X-ray tube.
RATIONALE
Polymer sample spots for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) prepared by the dried-droplet method often reveal ring formation accompanied by possible segregation of matrix and sample molecules as well as of the polymer homologs itself. Since the majority of sample spots are prepared by this simple and fast method, a matrix or sample preparation method that excludes such segregation has to be found.
METHODS
Three different ionic liquid matrices based on conventionally used aromatic compounds for MALDI-TOF MS were prepared. The formation of ionic liquids was proven by 1H NMR spectroscopy. MALDI-Imaging mass spectrometry was applied to monitor the homogeneity.
RESULTS
Our results show a superior sample spot homogeneity using ionic liquid matrices. Spots could be sampled several times without visible differences in the mass spectra. A frequently observed loss of matrix in the mass spectrometer vacuum was not observed. The necessary laser irradiance was reduced, which resulted in less polymer fragmentation.
CONCLUSIONS
Ionic liquid matrices can be used to overcome segregation, a typical drawback of conventional MALDI dried-droplet preparations. Homogeneous sample spots are easy to prepare, stable in the MS vacuum and, thereby, improve the reproducibility of MALDI.
The Radon transform tomography is used for reconstruction of the emissivity distribution in single- (SP) and double-pulse (DP) laser induced plasmas in orthogonal geometry. The orthogonal DP plasma is intrinsically asymmetric and thus suitable for the Radon reconstruction. The DP plasma consists of two plasmas separated by a short time interval of ~ 1 µs. The first plasma is created in air near the surface of a Si wafer and is followed (pre-ablation mode) or preceded (post-ablation mode) by the second plasma induced on this surface. A spectrometer moves in a semi-circular path around the plasma keeping the plasma in the rotation center. The optical detection is arranged so that a thin plasma layer parallel to the target surface is monitored. The axial symmetry of the SP plasma is investigated by comparing data from the Abel inversion taken at different angles and Radon reconstruction. The multi-angle measurements are used to estimate errors of the Abel reconstruction due to asymmetries of the plasma. Time-resolved Radon reconstruction in white light is performed for the DP plasma in both pre- and post-ablation modes. In the former case, the effect of ablated aerosol on the formation of the air plasma is monitored. In the latter case, a formation of an asymmetric compression shock created by the target plasma inside the air plasma is visualized. This observation is supported by computer simulations. An interaction of the two plasmas is studied by spectrally resolved Radon reconstruction revealing a complex distribution of target and ambient species inside the plasma at all studied delay times. Overall, it is demonstrated that Radon-based tomography is an informative tool to study transient asymmetric laser induced plasmas.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was utilized for spatially resolved bioimaging of the distribution of silver and gold nanoparticles in individual fibroblast cells upon different incubation experiments. High spatial resolution was achieved by optimization of scan speed, ablation frequency, and laser energy. Nanoparticles are visualized with respect to cellular substructures and are found to accumulate in the perinuclear region with increasing incubation time. On the basis of matrix-matched calibration, we developed a method for quantification of the number of metal nanoparticles at the single-cell level. The results provide insight into nanoparticle/cell interactions and have implications for the development of analytical methods in tissue diagnostics and therapeutics.
The influence of a humid or dry atmosphere on acoustically levitated ionic liquid droplets was studied by volumetric analysis and vibrational spectroscopy. Imidazolium-based ionic liquids with two types of anions, fluorinated (BF4 and PF6) and alkylsulfate anions, were investigated. The amount of absorbed water was correlated with structural differences of the ionic liquids and analyzed in terms of equilibrium mole fraction as well as absorption rate. The type of anion had the most significant influence on the amount of adsorbed water from the atmosphere. Furthermore, spectral changes in the in situ Raman spectra due to absorbed water were studied for all investigated ionic liquids. For 1-ethyl-3-methylimidazolium ethylsulfate, an exemplary detailed analysis of the intermolecular interactions between cations, anions and water was carried out based on the spectroscopic data. The observed band shifts were explained with a hydrogen bond between the anion and water.
For many analytical purposes, direct laser ionization of liquids is desirable. Several studies on supported droplets, free liquid jets, and ballistically dispensed microdroplets have been conducted, yet detailed knowledge of the underlying mechanistics in ion formation is still missing. This contribution introduces a simple combination of IR-MALDI mass spectrometry and an acoustical levitation device for contactless confinement of the liquid sample. The homebuilt ultrasonic levitator supports droplets of several millimeters in diameter. These droplets are vaporized by a carbon dioxide laser in the vicinity of the atmospheric pressure interface of a time of flight mass spectrometer. The evaporation process is studied by high repetition rate shadowgraphy experiments elucidating the ballistic evaporation of the sample and revealing strong confinement of the vapor by the ultrasonic field of the trap. Finally, typical mass spectra for pure glycerol/water matrix and lysine as an analyte are presented with and without the addition of trifluoracetic acid, and the ionization mechanism is briefly discussed. The technique is a promising candidate for a reproducible mass spectrometric detection scheme for the field of microfluidics.
A method for the determination of 22 trace impurities in solar grade silicon after dissolution in a mixture of HF and HNO3 and subsequent matrix evaporation is reported. The presented method involves a simple, inexpensive, one-vessel sample preparation apparatus design. The recoveries of B, Na, Mg, Al, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Mo, Sb, W, and Tl at 250 µg kg-1 level are in the range of 93 to 108%. After careful selection of monitored isotopes and their respective resolutions, a sector field mass spectrometer has been used to carry out the measurements. Limits of determination down to 120 ng kg-1 have been obtained using a calibration by three-point standard addition. The method was tested on diluted NIST SRM 57b silicon powder as well as on synthetic test samples and also applied successfully on raw solar grade silicon samples in an interlaboratory comparison including NAA.
A method based on matching synthetic and experimental emissivity spectra was applied to spatially resolved measurements of a laser-induced plasma ignited in argon at atmospheric pressure. The experimental emissivity spectra were obtained by Abel inversion of intensity spectra measured from a thin plasma slice perpendicular to the plasma axis. The synthetic spectra were iteratively calculated from an equilibrium model of plasma radiation that included free free, free–bound, and bound–bound transitions. From both the experimental and synthetic emissivity spectra, spatial and temporal distributions of plasma temperature and number densities of plasma species (atoms, ions, and electrons) were obtained and compared. For the best-fit synthetic spectra, the temperature and number densities were read directly from the model; for experimental spectra, these parameters were obtained by traditional Boltzmann plot and Stark broadening methods. In both cases, the same spectroscopic data were used. Two approaches revealed a close agreement in electron number densities, but differences in plasma excitation temperatures and atom number densities. The trueness of the two methods was tested by the direct Abel transform that reconstructed the original intensity spectra for comparing them to the measured spectra. The comparison yielded a 9 and 13% difference between the reconstructed and experimental spectra for the numerical and traditional methods, respectively. It was thus demonstrated that the spectral fit method is capable of providing more accurate plasma diagnostics than the Boltzmann plot and Stark broadening methods.
Temperature is one of the most important physical parameters of plasmas induced by a focused laser beam on solid targets, and its experimental evaluation has received considerable attention. An intriguing approach, first proposed by Kunze (H.-J. Kunze, Experimental check of local thermodynamic equilibrium in discharges, Appl. Opt., 25 (1986) 13–13.) as a check of the existence of local thermodynamic equilibrium, is based upon the simultaneous measurement of the thermal emission and the optically saturated fluorescence of the same selected atomic transition. The approach, whose appealing feature is that neither the calibration of the set-up nor the spontaneous radiative probability of the transitions is needed, has not yet been applied, to our knowledge, to analytical flames and plasmas. A critical discussion of the basic requirements for the application of the method, its advantages, and its experimental limitations, is therefore presented here. For our study, Ba+ transitions in a plasma formed by focusing a pulsed Nd:YAG laser (1064 nm) on a glass sample containing BaO are selected. At various delay times from the plasma initiation, a pulsed, excimer-pumped dye laser tuned at the center of two Ba transitions (6s ²S1/2 → 6p ²P°3/2; 455.403 nm and 6p ²P°1/2 → 6d ²S1/2; 452.493 nm) is used to enhance the populations of the excited levels (6p ²P°3/2 and 6d ²S1/2) above their thermal values. The measured ratio of the emission and direct line fluorescence signals observed at 614.171 nm (6p ²P°3/2 → 5d ²D5/2) and 489.997 nm (6d ²S1/2 → 6p ²P°3/2) is then related to the excitation temperature of the plasma. Our conclusion is that the approach, despite being indeed attractive and clever, does not seem to be easily applicable to flames and plasmas, in particular to transient and inhomogeneous plasmas such as those induced by lasers on solids.
A commercially available airbrush gun as a new source for spray ionization is presented. It is best operated employing moderate stagnation pressures, resulting in a sonic gas flow. A mass spectrometric investigation on the amino acid lysine and several peptides reveals that this inexpensive approach results in reproducible mass spectra. The ion patterns strongly resemble the results from other studies obtained with custom made sonic spray vaporizers. The patterns as well resemble the mass spectra recorded with electrospray devices. For a better understanding of the vaporization process, the mass spectrometry experiments are accompanied by laser induced fluorescence experiments. Inverse Abel transform of the obtained fluorescence maps allows the determination of the full 3D distribution of the spray cone. Furthermore, via exploitation of the solvatochromism of the used dye the solvation state distribution can be visualized. In addition, expansion parameters like droplet size and velocity are obtained by laser stroboscopy. The experiments demonstrate that the analyte is hardly desolvated throughout the expansion. This indicates a subsequent vaporization of the residual solvent in the intermediate pressure region of the mass spectrometer.
A novel method for predictions of the sound pressure distribution in acoustic levitators is based on a matrix representation of the Rayleigh integral. This method allows for a fast calculation of the acoustic field within the resonator. To make sure that the underlying assumptions and simplifications are justified, this approach was tested by a direct comparison to experimental data. The experimental sound pressure distributions were recorded by high spatially resolved frequency selective microphone scanning. To emphasize the general applicability of the two approaches, the comparative studies were conducted for four different resonator geometries. In all cases, the results show an excellent agreement, demonstrating the accuracy of the matrix method.
The identification of transformation products (TPs) of pesticides in food is a crucial task difficult to tackle, due to the lack of standards. In this work, we present a novel methodology to synthesize five main TP standards of the insecticide chlorpyrifos (CPF) and to investigate their occurrence in selected fruits and spices. TPs were electrochemically (EC) synthesized using a boron-doped diamond electrode (BDD) and identified by EC coupled online to mass spectrometry, LC-MS/MS, and high-resolution mass spectrometry. CPF and its TPs were analyzed in the food samples by LC-MS/MS on multiple reaction monitoring (MRM) after dispersive solid-phase extraction. A good recovery of 83–103% for CPF and 65–85% for TPs was obtained. Matrix effects, which cause signal suppression, ranged between 81 to 95% for all targeted analytes. The limit of detection and quantification for CPF were 1.6–1.9 and 4.9–5.7 μg/kg, respectively. Among investigated samples, CPF was determined in fresh lemon (104 μg/kg), fenugreek seed (40 μg/kg), and black pepper (31 μg/kg). CPF content in all samples was lower than the EU maximum residue level (MRL). The most frequently detected TPs were diethylthiophosphate and diethylphosphate. Other TPs, CPF oxon and trichloropyridinol, were also detected. Hence, EC is a versatile tool to synthesize TP standards which enables the determination of contaminants and residues in foodstuffs even if no commercial standards are available.
Biomedical applications, including functional biomaterials, carbohydrate-arrays, and glycan-based biosensors.
The chemistry of glycan immobilization plays an essential role in the bioavailability and function of surface bound carbohydrate moieties. For biomedical applications the stability over time (shelf life) of glycan arrays is a crucial factor. Herein we report on approaches for surface and interface characterization relevant to the needs of production of glycan microarrays which were tested using model carbohydrate surfaces. For detailed characterization of glycan model surfaces we used a combination of X-ray photoelectron spectroscopy (XPS), near edge X-ray absorption fine structure spectroscopy (NEXAFS) and ToF SIMS which are complementary techniques of surface chemical analysis. Links to fluorescence spectroscopy often used for characterization in the microarray community were established as well. In detail, amine-reactive silicon oxide and glass surfaces were used for anchoring oligosaccharides with an amino linker. The amount of surface bound carbohydrates was estimated by X-ray photoelectron spectroscopy (XPS). Glycan immobilization was investigated using lectins, which are glycan-binding molecules. A shelf life study of model glycan microarrays on epoxy-coated glass surfaces was done over a period of 160 days under different storage conditions utilizing fluorescence, ToF-SIMS and XPS analysis. It was shown that glycan activity of the models used can be maintained at least for half a year of storage at 4 °C.
Polyethylene (PE) frits were used to quantify sulphur in copper and its alloys by isotope dilution combined with LA-ICP-MS as an alternative approach to conventional sample preparation: the copper samples were spiked, the spiked samples were dissolved, the resulting solutions were absorbed in the PE frits and finally the PE frits were analysed by LA-ICP-MS. A prerequisite for such a support material is a low sulphur blank and thus PE was selected for this purpose. The absorption efficiency of the PE frits was studied for varying sulphur amounts ranging from 2 mg S to 80 mg S showing that more than 99.5% of the loaded sulphur was absorbed by the frit. The so prepared PE frits were measured by LA-ICP-MS and yielded a good linearity (R2 ¼ 0.999) for the sulphur ion intensities corresponding to sulphur amounts up to 40 mg S; the associated sensitivity is approximately 3.4 x 10⁴ cps μg⁻¹ for ³²S. For the validation of the developed procedure the reference materials BAM-M376a, BAM-228 and BAM-227 were applied such that 2 μg S, 5 μg S and 11 μg S were absorbed in the PE frits, respectively. These samples were pre-quantified for the adsorbed sulphur amount by external calibration LA-ICP-MS yielding sulphur amounts of 0.9 μg, 5.1 μg and 8.5 μg (quantified for ³²S only), respectively. Relative Standard deviations of the isotope ratios were below 5% in average (n ¼ 3 lines) in all cases (except for the pure spike solution). These samples were then analysed by LA-ICP-IDMS and the measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. The obtained relative expanded measurement uncertainties ranged between 10% and 26%. Pearson's coefficient was used to express the correlation between both techniques; the obtained value was 0.999 demonstrating a strong correlation. Contrary to most published LA-ICP-IDMS procedures, the developed procedure enables SI-traceability for the measurement results. The metrological traceability to the SI for the sulphur mass fractions in copper was established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to mass fraction in the samples obtained by LA-ICP-IDMS is presented as well.
Quantification of metals in single cells by LA-ICP-MS comparison of single spot analysis and imaging
(2018)
LA-ICP-MS is increasingly used for single cell analysis in two different detection modes using either the imaging mode with subcellular resolution or alternatively single spot analysis of cells with a larger laser spot size. This study compares the analytical figures of merit of both detection modes (signal to noise, precision, accuracy, throughput), as well as ease of operation and data evaluation. Adherent 3T3 fibroblast cells were stained with two metal dyes (mDOTA-Ho, Ir-DNA-intercalator) and several dozen cells were measured using both modes. We found a ten times higher throughput for single spot analysis, which has as well a straightforward data analysis, shortening the total analysis time further. The signal to noise ratio for single spot analysis was found to be slightly better compared to the signal to noise of pixels in imaging. The mean metal intensity per single cell differed by only 10% between both modes and obtained distributions were found to show no statistically significant differences. Using matrix matched calibration based on standards spotted onto nitrocellulose membrane, we achieved detection limits (10 σ) of 12 fg for Ir and 30 fg for Ho and quantified 57 ± 35 fg Ir and 1,192 ± 707 fg Ho per single cell. Compared to a conventional ICP-MS measurement of a digest of ~60,000 cells, 54 % of Ir content and 358 % Ho content was found using quantitative LA-ICP-MS. The difference might be a consequence of the two metal dyes binding to different structures of the cell and therefore might behave differently in sample preparation for conventional and LA-ICP-MS.
Iron nanoparticles (NPs) metabolism is directly associated to human health due to their use as anemia treatment and should be studied in detail in cells. Here we present a speciation strategy for the determination of the metabolic products of iron oxide nanoparticles coated by tartaric and adipic acids in enterocytes-like cell models (Caco-2 and HT-29). Such methodology is based on the use of SDS-modified reversed phase high performance liquid chromatography (HPLC) separation using inductively coupled plasma-mass spectrometry (ICP-MS) as Fe selective detector. Post-column isotope dilution analysis is used as quantification tool by adding Fe-57 as isotopically enriched standard. To assess the separation capability of the method, two different iron nanostructures: iron sucrose nanoparticles -Venofer®- used as model suspension and iron tartrate/adipate-modified nanoparticles, both of about 4 nm (core size) were evaluated. The two nanostructures were injected into the system showing good peak profiles and quantitative elution recoveries (>80%) in both cases. In addition, both nanoparticulate fractions could be based-line separated from ionic iron species, which needed to be complexed with 1mM citrate to elute from the column. Exposed cells up to 0.5mM of iron tartrate/adipate-modified nanoparticles were specifically treated to extract the internalized NPs and the extracts examined using the proposed strategy. The obtained results revealed the presence of three different fractions corresponding to nanoparticle aggregates, dispersed nanoparticles and soluble iron respectively in a single chromatographic run. Quantitative experiments (column recoveries ranging from 60 to 80%) revealed the presence of the majority of the Fe in the nanoparticulated form (>75%) by summing up the dispersed and aggregate particles. Such experiments point out the high uptake and low solubilization rate of the tartrate/adipate NPs making these structures highly suitable as Fe supplements in oral anemia treatments.
Estrone (E1), a metabolite of the estrogenic hormones 17β-estradiol (β-E2) and 17α-estradiol (α-E2), is itself a potent estrogen which can have a significant impact on the hormonal balance. Due to ist high potential for adverse effects on human health and aquatic life even at pg/L to ng/L levels, its appearance in water should be monitored. E1 has also been considered a marker substance for the presence of other estrogens. This study presents a newly developed direct competitive enzymelinked immunosorbent assay (ELISA) for quantification of E1 in environmental water samples using new monoclonal antibodies.
The quantification range of the ELISA is 0.15 μg/L to 8.7 μg/L E1, and the limit of detection is around 60 ng/L for not pre-concentrated water samples. A pre-concentration step after careful selection of suitable phases for SPE was developed, too. The influence of organic solvents and natural organic matter on the ELISA was assessed. The high selectivity of the monoclonal antibody was demonstrated by determining the cross-reactivity against 20 structurally related compounds.
For the assessment of matrix effects, a concept (“LC–ELISA”) is thoroughly exploited, i.e., separating complex samples by HPLC into 0.3 min fractions and determination of the apparent E1 concentration. Furthermore, fractions with interferences for nontarget/suspected-target analysis can be assigned. A dilution approach was applied to distinguish between specific interferences (cross-reactants) and non-specific interferences (matrix effects). In the determination of 18 environmental samples, a good agreement of the E1 concentration in the respective fractions was obtained with mean recoveries of 103 % to 132 % comparing ELISA to LC–MS/MS.
The meeting was organised by the European Commission’s Joint Research Centre and held at the JRC-Geel site on 22–23 February 2018. It was a follow-up of a similar meeting held in 2009. The objective of the meeting was to exchange information about ongoing publicly funded reference material (RM) production, identify areas of interest for future specific RMs, including certified reference material (CRM) developments, investigate potential areas of collaboration, and to identify areas which may be of a lower importance in the future for a specific RM producer. The benefit of exchanging such information is to avoid duplication of efforts in RM production, make better use of public funds by potentially matching competencies, and to address problems that are common to publicly funded RM producers.
The mechanism of action of zirconium permanent modifiers on graphite surfaces was investigated in order to understand its influence on the analytical signal in atomic and molecular absorption spectrometry (AAS/MAS). For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. We propose here a mechanism, where ZrO2 acts as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface. No evidence of the formation of zirconium carbide was found. Consequently, as the CaF formation is catalysed by a heterogeneous catalyst, surface modifications with ZrO2 nanoparticles and ZrO xerogels were investigated in order to increase the surface area. Their influence was evaluated in the molecule formation of CaF, CaCl, CaBr, and CaI. Graphite furnace modification with zirconium oxide nanoparticles proves to be the best choice for fluorine analysis with a signal enhancement of more than eleven times with respect a non-coated graphite furnace. However, the influence of zirconium modifications in the analytical signals of Cl, and I is lower than the F signals or even negative in case of the Br. Understanding zirconium modifiers as heterogeneous catalysts offers a new perspective to AAS and MAS, and reveals the potential of surface analytical methods for development of improved permanent modifiers and graphite furnace coatings.
Identifying the fate of agrochemicals is important to understand their potential risk for living organisms. We report here new photodegradation products (PPs) of the fungicide fluopyram. The PPs were produced by irradiating a fluopyram standard in 0.1% acetonitrile aqueous media by a 150-W medium pressure Hg-lamp that emits wavelengths between 200–280 nm. The structural elucidation of PPs was achieved by combining the retention time, isotopic pattern, targeted fragmentation, and accurate mass measurements using liquid chromatography-tandem mass spectrometry (LC-MS/MS) and high resolution-MS (HRMS). In addition to previously known PPs, seven new PPs of fluopyram were identified in this work: mainly dihydroxyl and hydroxylimide fluopyram as well as mono, di, and trihydroxyl lactam. Additionally, two PPs were found to be formed by rearrangement after the loss of H2C=CH2. Hence, the results of the work contribute to extending the current knowledge regarding the photoinduced fate of agrochemicals, and fluopyram in particular.
Xenobiotics and their reactive metabolites are conjugated with native biomolecules such as glutathione and glucoside during phase II metabolism. Toxic metabolites are usually detoxified during this step. On the other hand, these reactive species have a potential health impact by disrupting many enzymatic functions. Thus, it is crucial to understand phase II conjugation reactions of xenobiotics in order to address their fate and possible toxicity mechanisms.
Additionally, conventional methods (in vivo and in vitro) have limitation due to matrix complexity and time-consuming. Hence, developing fast and matrix-free alternative method is highly demandable. In this work, oxidative phase I metabolites and reactive species of chlorpyrifos (insecticide) and fluopyram (fungicide) were electrochemically produced by using a boron-doped diamond electrode coupled online to electrospray mass spectrometry (ESI-MS). Reactive species of the substrates were trapped by biomolecules (glutathione and glucoside) and phase II conjugative metabolites were identified using liquid chromatography (LC)-MS/MS, and/or Triple time of flight (TripleTOF)-MS. Glutathione conjugates and glucosylation of chlorpyrifos, trichloropyridinol, oxon, and monohydroxyl fluopyram were identified successfully. Glutathione and glucoside were conjugated with chlorpyrifos, trichloropyridinol, and oxon by losing a neutral HCl. In the case of fluopyram, its monohydroxyl metabolite was actively conjugated with both glutathione and glucoside. In summary, seven bioconjugates of CPF and its metabolites and two bioconjugates of fluopyram metabolites were identified using electrochemistry (EC)/MS for the first time in this work. The work could be used as an alternative approach to identify glutathione and glucosylation conjugation reactions of other organic compounds too. It is important, especially to predict phase II conjugation within a short time and matrix-free environment.
An automated method is presented for fast simulation of (bio)transformation products (TPs) of the organophosphate insecticide chlorpyrifos CPF)based on electrochemistry coupled online to liquid chromatography-mass spectrometry (EC-LC-MS). Oxidative TPs were produced by a boron doped diamond (BDD) electrode, separated by reversed phase HPLC and online detected by electrospray ionization-mass spectrometry (ESI-MS). Furthermore, EC oxidative TPs were investigated by HPLC-tandem mass spectrometry (LC-MS/MS) and FT-ICR high resolution mass spectrometry (HRMS) and compared to in-vitro assay metabolites (rat and human liver microsomes). Main phase I metabolites of CPF: chlorpyrifos oxon (CPF oxon), trichloropyridinol (TCP), diethylthiophosphate (DETP), diethylphosphate (DEP), desethyl chlorpyrifos (De-CPF), and desethyl chlorpyrifos oxon (De-CPF oxon), were successfully identified by the developed EC-LC-MS method. The EC-LC-MS method showed similar metabolites compared to the in-vitro assay with possibilities of determining reactive species. Our results reveal that online EC-(LC)-MS brings an advantage on time of analysis by eliminating sample preparation steps and Matrix complexity compared to conventional in-vivo or in-vitro methods.
A simple metal staining procedure for identification and visualization of single cells by LA-ICP-MS
(2017)
High lateral resolution of metal detection in single cells by use of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) demands powerful staining methods. In this work different staining procedures for the single cell analysis with LA-ICP-MS were optimized. An iridium intercalator was utilized to stain the cell nuclei whereas the whole cell was stained by the use of maleimido-mono-amide-DOTA (mDOTA) complexing lanthanide(III) ions. The content of the artificially introduced metals per cell was quantified using a matrix matched calibration approach based on cellulose membranes onto which standards were spotted by a microarray spotter. Absolute metal stain amounts in the range of 2.34 to 9.81 femtomole per cell were determined. The metal staining procedures allow direct identification and visualization of single cells and their cell compartments by element microscopy without the use of bright field images of the sample.
An airborne laser plasma is suggested as an ambient ion source for mass spectrometry. Its fundamental physical properties, such as an excellent spatial and temporal definition, high electron and ion densities and a high effective cross section in maintaining the plasma, make it a promising candidate for future applications. For deeper insights into the plasma properties, the optical plasma emission is examined and compared to mass spectra. The results show a seemingly contradictory behavior, since the emitted light reports the plasma to almost entirely consist of hot elemental ions, while the corresponding mass spectra exhibit the formation of intact molecular species. Further experiments, including time- resolved shadowgraphy, spatially resolved mass spectrometry, as well as flow-dependent emission spectroscopy and mass spectrometry, suggest the analyte molecules to be formed in the cold plasma vicinity upon interaction with reactive species formed inside the hot plasma center. Spatial separation is maintained by concentrically expanding pressure waves, inducing a strong unidirectional diffusion. The accompanying rarefaction inside the plasma center can be compensated by a gas stream application. This replenishing results in a strong increase in emission brightness, in local reactive species concentration, and eventually in direct mass spectrometric sensitivity. To determine the analytical performance of the new technique, a comparison with an atmospheric pressure chemical ionization (APCI) source was conducted. Two kitchen herbs, namely, spearmint and basil, were analyzed without any sample pretreatment. The presented results demonstrate a considerably higher sensitivity of the presented laser-spark ionization technique.
Actual research demonstrates that LA-ICP-MS is capable of being used as an imaging tool with cellular resolution. The aim of this investigation was the method development for LA-ICP-MS to extend the versatility to quantitative and multiplexing imaging of single eukaryotic cells. For visualization of individual cells selected, lanthanide-labeled antibodies were optimized for immuno-imaging of single cells with LA-ICP-MS. The molar content of the artificial introduced labels per cell was quantified using self-made nitrocellulose-coated slides for matrix-matched calibration and calculated amounts were in the range of 3.1 to 17.8 atmol per cell. Furthermore, the quantification strategy allows a conversion of 2D intensity profiles based on counts per second (cps) to quantitative 2D profiles representing the molar amount of the artificial introduced elemental probes per pixel for each individual cell.
Green Fenton-like magnetic nanocatalysts: Synthesis, characterization and catalytic application
(2015)
Five iron oxalate core–shell magnetite nanoparticles catalysts are evaluated as magnetic heterogeneous materials. Simple and efficient procedures for the preparation of magnetic iron oxalate coated nanoparticles are presented. The catalysts are fully characterized using various investigation techniques. Additionally, the formation of photo-sensitized oxygen by spin-trapping using electron spin resonance is investigated. The catalytic activity of two model substrates (carbamazepine and bisphenol A) is also evaluated. The effect of operational parameters (catalyst and H2O2 concentration, UVA light) on the degradation performance of the oxidation process is investigated. The obtained reaction rates depend on the nature of the compound and increase with iron oxide shell thickness of the catalyst. Moreover, these materials show a significant activity during two consecutive tests. The optimum experimental parameters are found to be 1.0 g L−1 of catalysts, 10 mM H2O2, under UVA irradiation. More than 99% of both substrates are removed after 30 min of reaction time under the experimental conditions given above. The results obtained show that the catalysts are suitable candidates for the removal of pollutants in wastewaters by means of the Fenton heterogeneous reaction.
A spatial heterodyne spectrometer (SHS) is tested for the first time in combination with laser-induced breakdown spectroscopy (LIBS). The spectrometer is a modified version of the Michelson interferometer in which mirrors are replaced by diffraction gratings. The SHS contains no moving parts and the gratings are fixed at equal distances from the beam splitter. The main advantage is high throughput, about 200 times higher than that of dispersive spectrometers used in LIBS. This makes LIBS-SHS a promising technique for low-light standoff applications. The output signal of the SHS is an interferogram that is Fourier-transformed to retrieve the original plasma spectrum. In this proof-of-principle study, we investigate the potential of LIBS-SHS for material classification and quantitative analysis. Brass standards with broadly varying concentrations of Cu and Zn were tested. Classification via principal component analysis (PCA) shows distinct groupings of materials according to their origin. The quantification via partial least squares regression (PLS) shows good precision (relative standard deviation , 10%) and accuracy (within 6 5% of nominal concentrations). It is possible that LIBS-SHS can be developed into a portable, inexpensive, rugged instrument for field applications.
Methods for the determination of boron in various matrices described in the literature usually employ complexing agents like mannitol to retain the volatile boron species during matrix evaporation steps. However, also relatively high boron recoveries from silicon containing samples have been reported when no complexing agents were added to the digestion acids. The mechanism behind this matrix-dependant recovery has been investigated by studying the boron recovery in the analysis of solar grade silicon. It was found that the NH4+ ion formed by the reduction of nitric acid during sample digestion is responsible for the higher recovery of boron, which leads to a possible analysis method without the use of complexing agents if the sample preparation procedure is carefully optimized.