Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (168) (entfernen)
Schlagworte
- LIBS (12)
- ICP-MS (9)
- Acoustic levitation (7)
- ELISA (7)
- LC-MS/MS (7)
- Laser ablation (7)
- Speciation (7)
- Laser induced plasma (5)
- Laser-induced breakdown spectroscopy (5)
- Nanoparticles (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (28)
- P Präsident (23)
- P.0 Präsident und andere (23)
- 1.1 Anorganische Spurenanalytik (14)
- 6 Materialchemie (9)
- 1.6 Anorganische Referenzmaterialien (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (5)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- 6.3 Strukturanalytik (5)
- 1.8 Umweltanalytik (4)
The chemical characterization and discrimination of allergy-relevant pollen (common ragweed (Ambrosia artemisiifolia), white birch (Betula pendula), English oak (Quercus robur), and European linden (Tilia cordata)) has been studied by Raman microscopy. Spectra were obtained at different excitation wavelengths (514, 633, and 780 nm) and various methods were examined to minimize the strong fluorescence background. The use of a HeNe laser (633 nm) for excitation yields high-quality single pollen Raman spectra, which contain multiple bands due to pollen components such as carotenoids, proteins, nucleic acids, carbohydrates, and lipids. Multivariate classification, i.e. principal component analysis (PCA) and hierarchical cluster analysis, demonstrated the validity of the approach for discrimination between different pollen species.
Asymmetrical flow field-flow fractionation (AF4) was applied to characterize aquatic colloids from biological sewage plants and to infer information of colloidal loads, sources, and sinks within the plants, resp. the colloidal interaction with the aqueous phase and the sewage sludge. To characterize the colloids further, especially the distributions of colloid associated heavy metals, the AF4 system was coupled to an inductively coupled plasma mass spectrometer (ICP-MS). The size distribution is determined by AF4 with UV absorbance and fluorescence detection after a calibration by monodisperse polystyrene sulfonate standards (PSS). Samples from different sewage plants and from different depths and locations within a plant were compared. The fulvic/humic acid fraction with a particle diameter dp < 10 nm appeared to be comparable in all samples and decreases only slightly along the plants, whereas larger colloids with dp > 10 nm almost completely passed into the sewage sludge. The concentrations of the initial colloidal heavy metals decreased along the plants.
The stable carbon and nitrogen isotopic composition of urine and milk samples from cattle under different feeding regimes were analysed over a period of six months. The isotope ratios were measured with isotope ratio mass spectrometry (IRMS). The δ13C values of milk and urine were dependent on different feeding regimes based on C3 or C4 plants. The δ13C values are more negative under grass feeding than under maize feeding. The δ13C values of milk are more negative compared to urine and independent of the feeding regime. Under grass feeding the analysed milk and urine samples are enriched in 13C relative to the feed, whereas under maize feeding the 13C/12C ratio of urine is in the same range and milk is depleted in 13C relative to the diet. The difference between the 15N/14N ratios for the two feeding regimes is less pronounced than the 13C/12C ratios. The δ15N values in urine require more time to reach the new equilibrium, whereas the milk samples show no significant differences between the two feeding regimes.
For the investigation of small sample volumes, the use of an acoustic levitator was tested as a `sample holder' for hovering droplets in a synchrotron beam. It might be advantageous to use levitated droplets instead of samples confined in solid holders, especially for the study of crystallization processes where the influence of containing walls has to be minimized. In a first experiment, the crystallization of sodium chloride in a small droplet of aqueous solution has been followed with a time resolution of 30 s. The collected diffraction peaks are compared with data in the ICSD database.
ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment.
Gated detection with intensified detectors, e.g., ICCDs, is today the accepted approach for detection of plasma emission in laser-induced breakdown spectroscopy (LIBS). However, these systems are more cost-intensive and less robust than nonintensified CCDs. The objective of this paper is to compare, both theoretically and experimentally, the performance of an intensified (ICCD) and nonintensified (CCD) detectors for detection of plasma emission in LIBS. The CCD is used in combination with a mechanical chopper, which blocks the early continuum radiation from the plasma. The detectors are attached sequentially to an echelle spectrometer under the same experimental conditions. The laser plasma is induced on a series of steel samples under atmospheric conditions. Our results indicate that there is no substantial difference in the performance of the CCD and ICCD. Signal-to-noise ratios and limits of detection achieved with the CCD for Si, Ni, Cr, Mo, Cu, and V in steel are comparable or even better than those obtained with the ICCD. This result is further confirmed by simulation of the plasma emission signal and the corresponding response of the detectors in the limit of quantum (photon) noise.
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy in theoretical parameters used for calculations (Stark broadening coefficients and partition functions) and 3) plasma non-ideality (departure from thermal equilibrium, spatial and temporal inhomogeneities, optical thickness, etc.). In this study, the effects of experimental aberrations and accuracy of spectral data were investigated, assuming that the analytical plasma is ideal. Departure of the plasma conditions from ideality will be the object of future work. The current study was based on numerical simulation. Two kinds of metallic alloys, iron-based and aluminum-based, were studied. The relative weight of the error contributions was found to depend on the sample composition. For the here-investigated samples, the experimental aberrations contribute to the overall uncertainty on the quantitative results more than theoretical parameters. The described simulation method can be applied to the Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of any other kind of sample.
The application of metrology in chemical analysis is today hampered by psychological and practical barriers. The argumentation is based on the differences in physical and chemical metrology, which arises mainly from the objects of the measurements. The term measurement is discussed in the realm of analytical chemistry with a special focus on the inherent relation between chemical identification and determination as well as the consequent use of the concept of traceability and uncertainty.
Raman microscopy allows a non-destructive characterisation of inorganic and organic painting materials such as pigments and organic dyestuffs. The objectives of this study are the more recent organic pigments typically present in paintings and other art works from the 20th century. More than 20 organic synthetic pigments from different chemical classes could be identified by Raman spectroscopy using different excitation wavelengths (457.9, 476.5, 487.9, 514.5, 632.8, and 1064 nm). To evaluate the performance for real paint samples, varying paint mixtures of the Hansa Yellow pigment PY 3 and the binding medium Mowilith, a polyvinyl acetate (PVAC) compound, were characterised; PY 3 was determined at a 1 wt% level in the binder. In addition, commercial tube paints containing the quinacridone violet PV 19 were studied. The pigment was clearly identified in all of these more complex oil and acrylic paints. Finally, alizarin (PR 83) and a green copper phthalocyanine pigment (PG 7) could unambiguously be identified by Raman microscopy in the painting Woman with mandolin in yellow and red of Max Beckmann dating 1950. The discovery of a red naphthol AS pigment by Raman spectroscopy in a sample from the Three field workers by Georg Baselitz (1964/1965) demonstrated that in some cases complementary chromatographic methods are needed for a comprehensive identification of the organic pigments.