Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (20)
- Zeitschriftenartikel (12)
- Vortrag (12)
- Buchkapitel (6)
- Posterpräsentation (4)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (51)
- Deutsch (3)
- Mehrsprachig (1)
Referierte Publikation
- nein (55) (entfernen)
Schlagworte
- Fire (6)
- Sloshing (5)
- LNG (4)
- Road tankers (4)
- Turning maneuvers (4)
- Cargo (3)
- Driving (3)
- Experimental approach (3)
- LH2 (3)
- Rail damage (3)
- Tank (3)
- Centre plate (2)
- Dynamic loads (2)
- Earthquake (2)
- Energy dissipation (2)
- Experimental approaches (2)
- GFRP (2)
- Hazmat (2)
- Lightweight design (2)
- Load transfer (2)
- MLI (2)
- Maneuvers (2)
- Pendulum analogy (2)
- Perturbation (2)
- Pressure vessel (2)
- Railway (2)
- Railways (2)
- Safe (2)
- Securement (2)
- Simulation (2)
- Tanks (2)
- Test rig (2)
- Thermohydraulic (2)
- Transport externalities (2)
- Vessels (2)
- ABS (1)
- Assess (1)
- Assessing (1)
- B10 exposure (1)
- BLEVE (1)
- Biofuels (1)
- Bogie design (1)
- Bogie´s yaw friction (1)
- Bogie´s yaw stiffness (1)
- Boiling (1)
- Braking (1)
- Braking in a turn (1)
- Braking performance (1)
- Braking-in-a-turn maneuver (1)
- Braking-in-a-turn maneuvers (1)
- Carburizing (1)
- Cargo sloshing (1)
- Center of gravity shifting (1)
- Ceramic liners (1)
- Change in tensile properties (1)
- Commodities (1)
- Comparative assessment (1)
- Computational scheme (1)
- Conceptual design (1)
- Container (1)
- Convex bottom (1)
- Cryogenic storage tank (1)
- Damage (1)
- Decarbonization (1)
- Drag resistance (1)
- Driving style (1)
- Dry friction (1)
- Empirical Mode Decomposition (1)
- Energy (1)
- Energy efficiency (1)
- Energy losses in transportation (1)
- Energy saving (1)
- Energy saving potentials (1)
- Engineering design (1)
- Environmental assessment (1)
- Experimental methods (1)
- Explosion (1)
- FKM polymer (1)
- FVK-Tanks (1)
- Fiction (1)
- Filling procedere (1)
- Forschungsvorhaben (1)
- Frame (1)
- Friction energy (1)
- Friction wear (1)
- Fuel consumption (1)
- Furnace design (1)
- GPS (1)
- GPS Scheme (1)
- GPS data (1)
- Geometrical analysis (1)
- Gravity response (1)
- Hydrostatic pressure (1)
- Infrastructure (1)
- Infrastructure damage (1)
- JetFire (1)
- Jetfire (1)
- LPG (1)
- Lateral load transfer (1)
- Lateral load transfer ratio (1)
- Lateral stability (1)
- Liquefied hydrogen (1)
- Liquefied natural gas (1)
- Liquid cargo (1)
- Mechanical prtoperties (1)
- Mechanical stress (1)
- Methods (1)
- Mud circulation system (1)
- Mud pumps (1)
- Multi-Layer Insulation (1)
- Multibody dynamics (1)
- Newton approach Ship stability (1)
- Numerical simulation (1)
- PIV (1)
- Particle emissions (1)
- Pistons (1)
- Pool fire (1)
- Potentials (1)
- Pressure bottle (1)
- Propane storage tanks (1)
- Protection systems (1)
- Prüfstand (1)
- Prüftstand (1)
- Qualitätssicherung (1)
- Quasistatic (1)
- Rail (1)
- Rail damage (1)
- Railway transportation (1)
- Receptacle (1)
- Road (1)
- Roadways (1)
- Rolling resistance (1)
- Safety (1)
- Scheme (1)
- Sealing materials (1)
- Selective carburizing (1)
- Self-aligning bogies (1)
- Self-centering mechanism (1)
- Simulating (1)
- Sloshing affects (1)
- Sloshing cargo (1)
- Sloshing effect (1)
- Sloshing, transition matrix approach (1)
- Steering forces (1)
- Steering torques (1)
- Stored energy (1)
- Subway (1)
- Subway system (1)
- Tank shape (1)
- Thermal insulation (1)
- Thermal properties (1)
- Thermohydraulics (1)
- Tiefkalt (1)
- Transfer (1)
- Transition matrix approach (1)
- Transport efficiency (1)
- Transportation energy (1)
- Tribology (1)
- Trucking (1)
- Turning (1)
- Turning forces (1)
- Unmodellvorschriften (1)
- Vehicle (1)
- Vehicles (1)
- Vertical cylindrical tanks (1)
- Wasserdruckprüfung (1)
- Wheel forces (1)
- Wheel-track interaction (1)
- Wheel/track interaction (1)
- Yaw resistance (1)
- Yaw stiffness (1)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (55) (entfernen)
Eingeladener Vortrag
- nein (12)
Mechanical stress often accelerates the failure of polymer materials. The aim of this research is to study the interaction between the sealing material FKM and biofuels B10 (heating oil with 10% biodiesel). The mechanical stress test was carried out in a special apparatus. Both mechanical and non-mechanical stress tests were conducted on specimens at 20, 40, and 70 °C for 28 days to document changes in mass, volume, and tensile properties. Both increasing temperature and mechanical stress have a significant effect on the tensile strength of the FKM polymer when exposed to B10. The combination of increasing temperature and mechanical stress induced rupture within 2 h. It was also established that FKM polymer with pre-exposure in B10 survived longer during mechanical stress compared to specimens exposed only to air. With the support of infrared (IR) spectroscopy, we were able to confirm the penetration of B10 into the FKM polymer.
The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure.
What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank.
The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires.
The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures.
Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG)
establish themselves as important energy carriers in the transport
sector. Its storage requires tanks with Thermal Super Insulations
(TSI) to keep the transported fluid cold. TSI has proven itself in
various applications over a long time, but not in the land
transport sector, where accidents involving collisions, fires, and
their combination are to be expected. The focus of this study is
to investigate the behavior of different types of TSI when
exposed to a heat source that represents a fire. Therefore, a High-
Temperature Thermal Vacuum Chamber (HTTVC) was used that
allows the thermal loading of thermal insulation material in a
vacuum and measuring the heat flow through the TSI in parallel.
Within this study, 5 samples were tested regarding 3 different
types of MLI, rock wool, and perlites. The thermal exposure
caused different effects on the samples. In practice, this can be
connected to the rapid release of flammable gases as well as a
Boiling Liquid Expanding Vapour Explosion (BLEVE). These
results are relevant for the evaluation of accident scenarios, the
improvement of TSI, and the development of emergency
measures.
The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire.
In the course of decarbonizing the energy industry, cryogenic energy carriers as liquefied hydrogen (LH2) and liquefied natural gas (LNG) are seen as having great potential. In technical applications, the challenge is to keep these energy carriers cold for a long time. This is achieved in the road transport sector and also stationary applications by thermal super insulations (TSI) which based on double-walled tanks with vacuum and multilayer insulation (MLI) in the interspace. This study focuses on the behaviour of widely used combustible MLI in a fire scenario, at vacuum and atmospheric pressure conditions. The former corresponds to the typical design condition and the latter to the condition after an outer hull rapture of a tank. Furthermore, two fire scenarios were taken into account: a standard-oriented approach and a hydrocarbon fire-oriented approach. For the study, a test rig was applied that allows testing of TSI at industrial conditions and subsequent analysis of TSI samples. The test rig allows thermal loading and performance analysis of TSI samples at the same time. Comparing the tests, the samples degraded differently. However, no sudden failure of the entire MLI was observed in any test. These results are relevant for the evaluation of incidents with tanks for the storage of cryogenic fluids and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures.