Pressurisation of full-containment pressure vessels in fire is known to be driven by thermal stratification. The predominant mode of heat transfer to the contents (convection from the shell to the liquid phase) results in formation of „hot“ boundary layers. Sub-cooled boiling may also be present. The warm layer rises to the surface through buoyancy and bubble flow, increasing the surface of the liquid above that of the bulk temperature, and hence driving a pressure rise.
For reliable prediction of the complex effects governing vessel pressurization a three-dimensional numerical model is required. Work is being undertaken on such a model by other institutions in cooperation with this project.
The results are based on data1. Figure 3 displays temperatures of the tank wall and of the gas phase over testing time. It can be seen that a complete coating strongly delayed the heating of tank wall and gas phase, whereas the partly coated tanks only had a minor influence on temperature development. There was no significant difference between a half coated and a thirdly coated tank measurable. Figure 4 shows the internal pressure of tanks over testing time. Only the fully coated tank enabled a low pressure over 90 min testing time. Hence, a complete coating is necessary to guarantee the fire safety of hazmat tanks and a partly coating is not sufficient.
Transport safety depends in great extent of what happens to the cargo once the carrying vehicle derails or rollovers. The exposure of tanks to direct fire is a condition that potentially involves catastrophic consequences. Studying the behavior of the contained fluid under these drastic circumstances, is critical to develop methods and techniques to mitigate the serious consequences of many mishaps. In this paper, the experimental potentials of a Particle Image Velocimetry data acquisition system are described, for providing experimental data that could be used to calibrate mathematical models. As an example of the situations that need to be modelled, an experiment is described concerning the effect of the boundary conditions and protecting devices, on the rate of variation of pressure and temperature of the fluid in a tank exposed to a direct fire. In this regard, the results emphasize the importance of equipping the vessels with both thermal insulation and safety valves.
Small and large-scale tests have been carried out Pressure vessel – to improve numerical modelling Different types of fire must be distinguished Modelling of vessels were discussed Test configuration has been developed to see what happens in the vessel First results encourage us to continue the Research Thermohydraulics needs further work (boundary layers).