Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- nein (16) (entfernen)
Schlagworte
- VOC (4)
- Copiers (2)
- Dust (2)
- Emissions (2)
- Ozone (2)
- Printers (2)
- Air quality monitoring (1)
- Ammonia gas sensor (1)
- Blue Angel (1)
- Detection technology (1)
- Drucker (1)
- EFNDT Arbeitsgruppe 5 (1)
- Elektronische Nase (1)
- Emission test chamber (1)
- Emissionen (1)
- Emissionsmesskammer (1)
- Environmental label (1)
- Fluorescence (1)
- Fluoreszenzlöschung (1)
- Gas detection (1)
- Gas storage sites (1)
- Gefahrstoffe (1)
- Gefahrstoffnachweis (1)
- Geruchs-Sensorik (1)
- Hardcopy device (1)
- Hardcopygerät (1)
- Hazardous and toxic gasses and vapours (1)
- Kontrollen (1)
- Kopierer (1)
- Methane measuring (1)
- Miniaturized sensor device (1)
- Multi sensor device (1)
- Multi-gas sensor (1)
- Multigas-Sensorik (1)
- Mustererkennung (1)
- Nitroaromaten (1)
- On-line Sensorik (1)
- Ozon (1)
- Pump control (1)
- Quantification of gas concentrations (1)
- Selective permeability (1)
- Sensor (1)
- Sicherheit (1)
- Spatially distributed monitoring (1)
- Standard gas generator (1)
- Staub (1)
- Threats other than explosives (1)
- Umweltzeichen (1)
- Warfare substances (1)
Eingeladener Vortrag
- nein (1)
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
This paper deals with the development and investi-gation of a volatile organic compound (VOC) system for differ-ent scenarios. The integrated multi-sensor unit can detect dif-ferent gases through the integrated 3-fold VOC sensor, where-by a continuous measurement takes place. The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrat-ed Secure Digital (SD) card. If the previously determined limit range is exceeded, an alarm is generated. Due to the combina-tion of different components, numerous applications are possi-ble. The system is the first step or a tool towards further devel-opments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors, and it is still largely extended by application-specific influences.
Nitroaromaten und insbesondere Trinitrotoluol (TNT) sind weit verbreitete Spreng- und Umweltschadstoffe. Die größte Herausforderung bei der Detektion von TNT in der Gasphase ist der geringe Dampfdruck. Derzeit werden vielerorts günstige, schnelle, handliche und einfach zu bedienende Alternativen zur klassischen TNT-Analytik entwickelt. Aktuell existieren keine einheitlichen Richtlinien für Sprengstoffsensoren. Hier wird die Entwicklung eines Messplatzes zur Validierung von Sprengstoffsensoren sowie die Erprobung eines kompakten Mustersensors vorgestellt.
In preliminary work, gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. In this study, first experimental results are presented for adapting the technology for measuring methane (CH4). A material with suitable selective permeability was identified and utilized in a sensor setup containing the gas selective membrane and a reference membrane, both integrated in a measuring cell, to which a gas stream with defined CH4 concentrations was applied. The results prove the sensor's capability for measuring methane and indicate further application potential of the method, e.g., as a robust field monitoring technology, since CH4 is the major component of natural gas, town gas, and fracking gas.
TNT-Chemosensor-Gerät