Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (19)
- Beitrag zu einem Tagungsband (13)
- Beitrag zu einem Sammelband (8)
- Handbuch (2)
Sprache
- Englisch (42) (entfernen)
Schlagworte
- Corrosion (12)
- Concrete (7)
- Korrosion (7)
- Alkali-activated materials (4)
- Atmospheric corrosion (4)
- Cathodic protection (4)
- Reinforcement (4)
- Stainless steel (4)
- Hydrogen-induced stress corrosion cracking (3)
- Prestressing steel (3)
- Steel corrosion (3)
- Chromate (2)
- Civil engineering (2)
- Corrosion protection (2)
- Electrochemical tests (2)
- Grease (2)
- Hydrogen evolution (2)
- ICCP (2)
- Leaching (2)
- Monitoring (2)
- Non-destructive testing (2)
- Potential mapping (2)
- Prestressed systems (2)
- Rebar (2)
- Reinforcing steel (2)
- Self-corrosion (2)
- Stainless steels (2)
- Steel reinforcement (2)
- Wax (2)
- Aluminium (1)
- Approval (1)
- Atmospheric corrosion conditions (1)
- Betonkonstruktion (1)
- Betonstahl (1)
- Bodenanker (1)
- Bridge management (1)
- Carbonation (1)
- Cement (1)
- Chlorid-induced corrosion (1)
- Chloride (1)
- Chloride Induced Corrosion (1)
- Coating (1)
- Concrete parameters (1)
- Corrosion resistance (1)
- Corrosion surveys (1)
- Corrosion testing (1)
- Critical chloride content (1)
- Cunductive (1)
- Damage symptoms (1)
- Dauerhaftigkeit (1)
- Duplex stainless steels (1)
- EPR test (1)
- Electrochemical measurements (1)
- Electrochemical parameters (1)
- Electrochemical realkalisation (1)
- Embedded Sensors (1)
- Exposure tests (1)
- Failure (1)
- Fly ash (1)
- Free weathering (1)
- Galvanic corrosion (1)
- Galvanized construction elements (1)
- Galvanized elements (1)
- Galvanized rebar (1)
- Galvanized steel (1)
- Geopolymers (1)
- Grinding (1)
- Indoor swimming pools (1)
- Inspection (1)
- Integrated Monitoring System (1)
- Intercrystalline corrosion (1)
- KorroPad (1)
- Korrosionsschutz (1)
- Maintenance (1)
- Marine atmosphere (1)
- Maritime Atmosphäre (1)
- Maritime atmosphere (1)
- Mercury intrusion measurements (1)
- Nicht rostender Stahl (1)
- Nichtrostender Stahl (1)
- Passive layer (1)
- Pitting corrosion (1)
- Polarization (1)
- Pore structure (1)
- Post-tensioned concrete (1)
- Potential (1)
- Potentialfeldmessung (1)
- Pozzolan (1)
- Prestressed concrete (1)
- Pull-out tests (1)
- Reinforced concrete (1)
- Reinforcement corrosion (1)
- Salinization (1)
- Sensors (1)
- Sprayed zinc layer (1)
- Stahl, austenitisch (1)
- Stahl, doppel rostfrei (1)
- Stahlbeton (1)
- Steel-concrete interface (1)
- Stress corrosion cracking (1)
- Streßkorrosion (1)
- Surface finish (1)
- Surface protection system (1)
- Versalzung (1)
- Verzinkt (1)
- Werkstoffauswahl (1)
- X-ray tomography (1)
- Zinc (1)
- reinforcement (1)
Organisationseinheit der BAM
Use of Embeddable Sensors in an Integrated Monitoring System for Reinforced Concrete Structures
(2003)
Systematic laboratory and field exposure tests allow to compare nine different stainless steels (three ferritic, three austenitic, and three duplex grades) for civil engineering applications. The influence of surface finish was also taken into account by choosing five different industry-specific features. The three duplex stainless steels revealed excellent corrosion resistance under most of the test conditions. Especially for applications in civil engineering the lean duplex steels offer distinct advantages. The manganese-alloyed 1.4376 and the ferritic steel 1.4509 cannot be recommended as alternative materials as they did not perform satisfactorily.
This specification describes how corrosion monitoring is used to check the condition of reinforced and prestressed concrete members. In this specification, the term "corrosion monitoring" covers all methods in which it is possible to continuously track corrosion-relevant variables in the area of stationary, built-in sensors. This specification does not cover other possible methods, such as potential field measurements, involving the use of mobile, portable sensors that are placed temporarily on the membersurface to take measurements.
Due to the large number of stainless steels with different chemical composition and different microstructure the selection of the suitable material represents a huge challenge. In order to facilitate the appropriate grade selection, in the current European standard EN 1993-1-4 a procedure is defined based on the use of a look-up table considering the key variables that influence the selection of stainless steels. The table uses descriptions that competent designers should be able to readily understand or define without prior knowledge. The output from the look-up table is used to select alloys based on a Corrosion Resistance Class (CRC) from I to V. The advantage of this approach is that the designer simply specifies the relevant CRC and does not need to consider in detail which of the many (very similar) alloys to specify.
Risk of stress corrosion cracking of prestressing steels in contact with galvanized components
(2010)
Long-term experiences with cathodic corrosion protection of steel reinforced concrete structures
(2002)
Nine different stainless steel alloys were exposed for 5 years under marine environment and their corrosion behaviour was compared and assessed. The investigation of four different surface finishes for all alloys tested further enabled to consider industry-specific features of the surface finish for the material comparison. The results of the exposure tests yield conclusions regarding the influence of alloy composition, surface finish and exposure duration under marine environment. The three duplex stainless steels revealed excellent corrosion resistance even in case of crevices during the 5 years of exposure under the given exposure conditions. Also the molybdenum-alloyed ferritic steel 1.4521 showed good corrosion resistance comparable to the classical austenitic materials 1.4301 and 1.4404.
Alkali-activated fly ash mortars were studied with regard to durability-relevant transport coefficients and the electrochemical behaviour of embedded carbon steel bars on exposure of the mortars to leaching, carbonation and chloride penetration environments. The transport coefficients differed considerably between different formulations, being lowest for a mortar with BFS addition, but still acceptable for one of the purely fly ash-based mortars. Leaching over a period of ~300 days in de-ionized water did not lead to observable corrosion of the embedded steel, as shown by the electrochemical data and visual inspection of the steel. Exposure to 100 % CO2 atmosphere caused steel depassivation within approx. two weeks; in addition, indications of a deterioration of the mortar were observed. The results are discussed in the context of the different reaction products expected in high- and low-Ca alkali-activated binders, and the alterations caused by leaching and carbonation.
The presented investigations have proved the principal suitability of the KorroPad method to assess the passive layer stability of stainless steels. The electrochemical mode of action could be described in detail and limitations of the applicability have been demonstrated. The influence of different surface finishes has been investigated and verified by known methods for describing corrosion resistances. As a result, the increased corrosion susceptibility of two ground surfaces has been detected, but also the corrosion resistance of further surface finishes could be confirmed.
About the long-term protection behaviour of corrosion protection materials (filling materials) for prestressed systems under critical environmental conditions is only little known. The corrosion protection effect is usually based on theoretical considerations and is proven by short-term tests. The selection of the different products is mainly made according to economical or workability criteria. In a research project the barrier effect of different commercial corrosion protection materials (waxes as well as oil-based greases) against water, their tendency for undercutting as well as their additional corrosion protection effect were investigated. The exposure tests were carried out with non-stressed as well as stressed prestressing steel specimens which were subjected to critical conditions (condensed water, artificial soil solution, direct soil contact). Parallel to these long-term exposure tests the applicability of different electrochemical techniques and their significance with respect to testing the corrosion protection ability and water absorption was evaluated. Within the project a suitable method for simple testing the performance of corrosion protection materials under real conditions was developed. By means of a small compact cell submicroscopical reactions of the used sensors could be measured. The high sensitivity of this measuring technique enables the detection of degradation processes at thin protection layers.
Investigations of corrosion on small cathodes in reinforced concrete - observations and suggestions
(2009)
Corrosion of steel reinforcement in concrete exposed to chloride containing environments is a serious
problem in civil engineering practice. The standards and guidelines contain only minimum
requirements regarding concrete quality and concrete cover. In very critical cases, for example the
ingress of chlorides, the application of different coatings is currently the only possibility to protect the
reinforced concrete structures. In this case the modelling of reinforcement corrosion would be more
practical. One sub-project of a DFG-research project (FOR 537) is currently performed at the Federal
Institute for Materials Research and Testing (BAM). Aim of the sub-project is the description of
corrosion propagation and the characterization of the corrosion on specimens with small cathodes by
electrochemical parameters. The electrochemical parameters are determined by suitable
electrochemical measurements, considering concrete parameters as well as different environmental
conditions.
The salinization and contamination of metal surfaces by chloride-containing aerosols is of great importance with regard to corrosion phenomena of damaged coated metal surfaces and stainless steels in the maritime sector and in offshore applications. Detailed questions have to be answered to clarify whether and to what extent salinization of the surface has an influence on the adhesion and durability of coatings in repairing applications and on pitting occurrence on stainless steels under atmospheric conditions. The questions arise which degree of salinization is reached after which period of time and how a defined and reproducible salinization can be simulated in the laboratory for further systematic investigations. The article is dedicated to these questions. Results of a field trial on the Island of Heligoland are presented and a simple procedure for a defined loading of metal surfaces with chlorides at a laboratory scale using a design of experiments (DoE) approach is introduced.
The corrosion resistance of aluminium surfaces is closely linked to the surfacecstate after a grinding process. For years, iron‐containing abrasive materials were suspected to lead to increased corrosion susceptibility after processing of aluminium surfaces. To prove a possible correlation between the iron content of an abrasive and the corrosion behaviour of aluminium components, scientific investigations and experimentally practical corrosion tests are necessary.
For the current investigation, specimens of a technical Al‐Si alloy from the same batch were used. The test specimens were mechanically ground with various resin‐bonded model abrasives containing different iron contents. The performed corrosion tests did not reveal a negative influence of the different iron‐containing abrasives on the corrosion behaviour of the Al–Si alloy.
However, the most sensitive measuring method (electrochemical noise)
showed differences in the surface activity depending on the type of abrasive.
Steel in concrete is protected by the alkaline pore water environment and the resulting formation of a protective passive layer against corrosion. Adverse environmental conditions due to carbonation or chloride ingress can destroy the passive layer on the steel surface. Corrosion processes starting in those areas lead to uniform corrosion or local corrosion like pitting corrosion. In comparison to uniform corrosion pitting corrosion is a form of increased local corrosion and thus leads to a progressive reduction in cross-section of the reinforcing steel. The corrosion products are first absorbed by the pores of the concrete matrix, without causing visible external changes at the concrete surface.