Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (18) (entfernen)
Schlagworte
- Concrete (4)
- Corrosion (4)
- Alkali-activated materials (3)
- Cathodic protection (2)
- Einflussgrößen (2)
- ICCP (2)
- Leaching (2)
- Steel corrosion (2)
- Steel reinforcement (2)
- Betonstahl (1)
- Bridge management (1)
- Carbonation (1)
- Chloride (1)
- Chloride Induced Corrosion (1)
- Chromate (1)
- Coating (1)
- Concrete parameters (1)
- Cunductive (1)
- Embedded Sensors (1)
- Fehlerquellen (1)
- Galvanized construction elements (1)
- Galvanized rebar (1)
- Geopolymers (1)
- Hydrogen evolution (1)
- Hydrogen-induced stress corrosion cracking (1)
- Inspection (1)
- Integrated Monitoring System (1)
- Kathodische Polarisation (1)
- Korrosion (1)
- Maintenance (1)
- Messraster (1)
- Nachweisgrenzen (1)
- Pitting corrosion (1)
- Praktische Bedeutung (1)
- Prestressed concrete (1)
- Prestressing steel (1)
- Prüfprotokoll (1)
- Rebar (1)
- Reinforcement (1)
- Reinforcement corrosion (1)
- Self-corrosion (1)
- Sensors (1)
- Spannbeton (1)
- Spannstahl (1)
- Verfahrensbeschreibung (1)
- Verzinkt (1)
- Verzinkte Einbauteile (1)
- Wasserstoffinduzierte Spannungsrisskorrosion (1)
- X-ray tomography (1)
- reinforcement (1)
Organisationseinheit der BAM
Long-term experiences with cathodic corrosion protection of steel reinforced concrete structures
(2002)
Investigations of corrosion on small cathodes in reinforced concrete - observations and suggestions
(2009)
Corrosion of steel reinforcement in concrete exposed to chloride containing environments is a serious
problem in civil engineering practice. The standards and guidelines contain only minimum
requirements regarding concrete quality and concrete cover. In very critical cases, for example the
ingress of chlorides, the application of different coatings is currently the only possibility to protect the
reinforced concrete structures. In this case the modelling of reinforcement corrosion would be more
practical. One sub-project of a DFG-research project (FOR 537) is currently performed at the Federal
Institute for Materials Research and Testing (BAM). Aim of the sub-project is the description of
corrosion propagation and the characterization of the corrosion on specimens with small cathodes by
electrochemical parameters. The electrochemical parameters are determined by suitable
electrochemical measurements, considering concrete parameters as well as different environmental
conditions.
Use of Embeddable Sensors in an Integrated Monitoring System for Reinforced Concrete Structures
(2003)
Alkali-activated materials such as geopolymers are currently receiving a lot of attention because of their potential to be used as binders for concrete with advantageous engineering properties and reduced manufacturing CO2 emissions. Knowledge of the durability of steel in these concretes and related properties of alkali-activated materials is a prerequisite for their application as building materials, if they are to be used for steel reinforced elements. However, to date only limited data exists on this topic. The present contribution focuses on durability-related transport properties of geopolymer-based mortars (as model systems for concrete). We report results of accelerated carbonation, rapid chloride migration (RCM) and air permeability measurements as well as porosity data for fly ash-based geopolymer mortars, including mixes containing ground granulated blast furnace slag (GGBFS). In addition, we report polarization resistance data and corrosion potential vs. time curves for carbon steel bars embedded in two of the fly ash-based geopolymer mortars and a CEM I-based mortar (as reference).
Despite comparable total porosities, the carbonation depths, the chloride migration coefficients and the air permeabilities of the mortars differed significantly. In general, the addition of GGBFS to the binders improved the performance (decreased transport coefficients); however, this was not found to be true for the air permeability in all cases. This latter effect can be explained by drying damage of the C-(A-)S-H gel in GGBFS-containing binders. On the other hand, low transport coefficients can also be achieved by optimization of the binder formulation without the addition of GGBFS, which is also reflected in the material’s air permeability. Thus, there exists no simple correlation between air permeability (of harshly dried mortars) and durability-related transport coefficients for the studied alkali-activated materials.
The corrosion potential vs. time curves in combination with polarization resistance values reveal that the steel reinforcement in geopolymer mortars assumed a passive state. However, this happened considerably later than for steel in CEM I-based mortars. The free corrosion potential of carbon steel reinforcement in the geopolymer mortars had different values than the free corrosion potential values for the CEM I-based mortar for both the active and the passive state; possible reasons for this behavior are discussed.
Corrosion behavior of galvanized reinforcement in chloride containing mortar and carbonated mortar
(2018)
Korrosionseigenschaften von feuerverzinktem Betonstahl unterscheiden sich grundlegend von herkömmlichen Betonstahl. In diesem Vortrag sind Beispiele für das Korrosionsverhalten in chloridhaltigen und carbonatisierten Mörteln dargestellt
Corrosion of steel reinforcement in concrete is one of the major deterioration mechanisms limiting the service life of reinforced concrete structures. While for conventional (Portland cement-based) concretes a great amount of experience exists in this regard, the factors that determine the onset of reinforcement corrosion in alkali-activated materials are incompletely understood yet. One aspect of corrosion protection is leaching and the accompanying changes of the concrete pore solution. In the present study, alkali-activated fly ash mortars with embedded carbon steel rebars were exposed to de-ionised water for periods up to 330 days, and the electrochemical response of the steel (free corrosion potential, polarisation resistance), the alteration of the mortar (ohmic resistance, mechanical strength, pore size distribution) as well as the pore solution composition were monitored. Although substantial alkali leaching was observed, the pH of the pore solution remained at values sufficient to protect the embedded steel from depassivation. The mortar did not exhibit indications of significant deterioration. Thus, the present results suggest that leaching is not critical for protection of steel reinforcement in alkali-activated fly ash mortars and concretes.
Carbon‐based conductive coatings are complex composites, consisting of an organic or inorganic binder and conductive carbon components, for application as anodes in impressed current cathodic protection systems of reinforced concrete structures. The electrochemical properties of three coatings at different humidity and in saturated calcium hydroxide solution were studied by electrochemical methods, such as electrochemical impedance measurement, measuring of open circuit potential over time and galvanostatic polarization. The dissolved organic and inorganic carbons in electrolyte solution were quantified by using a photometric method. The structures of the coatings were investigated before and after the electrochemical tests by microscopy and scanning electron microscope/EDX analysis. The results of the electrochemical impedance measurements show that the tested coatings all have a relatively low resistance, which is between 100 and 200V. The binder and the surface porosity influence the degradation behavior of those coatings. Especially the organic binder reacts with the strong alkaline medium under dissolving of organic carbon.
Steel in concrete is protected by the alkaline pore water environment and the resulting formation of a protective passive layer against corrosion. Adverse environmental conditions due to carbonation or chloride ingress can destroy the passive layer on the steel surface. Corrosion processes starting in those areas lead to uniform corrosion or local corrosion like pitting corrosion. In comparison to uniform corrosion pitting corrosion is a form of increased local corrosion and thus leads to a progressive reduction in cross-section of the reinforcing steel. The corrosion products are first absorbed by the pores of the concrete matrix, without causing visible external changes at the concrete surface.
Carbon-based conductive coatings are complex composites, consisting of an organic or inorganic binder and conductive carbon components, for application as anodes in impressed current cathodic protection systems of reinforced concrete structures. The electrochemical properties of three coatings at different humidity and in saturated calcium hydroxide solution were studied by electrochemical methods, such as electrochemical impedance measurement, measuring of open circuit potential over time and galvanostatic polarization.
Alkali-activated fly ash mortars were studied with regard to durability-relevant transport coefficients and the electrochemical behaviour of embedded carbon steel bars on exposure of the mortars to leaching, carbonation and chloride penetration environments. The transport coefficients differed considerably between different formulations, being lowest for a mortar with BFS addition, but still acceptable for one of the purely fly ash-based mortars. Leaching over a period of ~300 days in de-ionized water did not lead to observable corrosion of the embedded steel, as shown by the electrochemical data and visual inspection of the steel. Exposure to 100 % CO2 atmosphere caused steel depassivation within approx. two weeks; in addition, indications of a deterioration of the mortar were observed. The results are discussed in the context of the different reaction products expected in high- and low-Ca alkali-activated binders, and the alterations caused by leaching and carbonation.