Ultrasonic imaging of tendon ducts enables the precise localisation of grouting faults in many cases. Additionally to well known criteria for detecting grouting faults in tendon ducts recently new possibilities were developed. Two main effects influence the complex behaviour of wave propagation and reflection: a) different arrangement and number of strands or internal rebars; b) superposition of reflecting signals and different wave modes propagating into the interface region around the tendon duct. In order to understand the experimental results, EFIT modelling is performed (EFIT: Elastodynamic Finite Integration Technique).
This paper presents the progress of successful location of grouting faults in tendon ducts with ultrasonic imaging. The examples were obtained in the research group FOR 384 funded by DFG (German Research Foundation). The co-operation of experimental research and modeling allowed imaging and identification of grouted and ungrouted areas of tendon ducts (including strands) in a large test specimen (40 m²). In addition to the criteria for indicating grouting faults in post-tensioned ducts known until now the phase evaluation of reflected ultrasonic pulses is described. Experiments and modeling of wave propagation are presented for reflections at metal plates in concrete (thickness range 0.5 mm to 40 mm) and for tendon ducts including strands.
The main part of the progress was achieved by automated measurements using dry contact transducers, 3D-SAFT reconstruction including phase evaluation and modeling considering wave propagation for typical elastic parameters and exact experimental site conditions. The results for shear waves as well as for pressure waves are compared in the frequency range from 50 kHz to 120 kHz.