Filtern
Dokumenttyp
- Zeitschriftenartikel (11) (entfernen)
Schlagworte
- Sewage sludge ash (4)
- CRM (2)
- Incinerator ash (2)
- RoHS (2)
- Röntgenfluoreszenzanalyse (2)
- Aging (1)
- Aluminium phosphate (1)
- Aluminum phosphate (1)
- Ash (1)
- Chemical stabilization of high-temperature forms (1)
- Coating (1)
- Cristobalite form (1)
- Electrochemistry (1)
- Electrotechnical products (1)
- Elektrischer Lichtbogenofen (1)
- Elemental analytical mehtods (1)
- Elemental composition (1)
- European reference material (1)
- Fertilizers (1)
- Filterstäube aus Müllverbrennungsanlagen (1)
- Fluorescence (1)
- Fluoride (1)
- Fly ash (1)
- Funkenspektrometrie (1)
- Homogenitätstest (1)
- ICP OES (1)
- ICP-OES (1)
- Inertisierung (1)
- LA-ICP-MS (1)
- Lanthanide (1)
- Lifetime (1)
- Method (1)
- Mineral phases (1)
- Nano (1)
- P-recovery (1)
- Palladium (1)
- Particle (1)
- Phosphorus recovery (1)
- Platinum (1)
- Precious metals (1)
- Printed circuit boards (1)
- Pure copper (1)
- Quality assurance (1)
- Quantification (1)
- Reference material (1)
- Referenzmaterialien (1)
- Rhodium (1)
- Sample dissolution (1)
- Stability (1)
- Stacking disorder (1)
- Surface chemistry (1)
- TEM (1)
- Thermochemical treatment (1)
- Tridymite form (1)
- Upconversion (1)
- Urban mining (1)
- Verfahrenspräzision (1)
- X-ray diffraction (1)
- XRD (1)
- XRF (1)
- ZnO-Reduktion (1)
Organisationseinheit der BAM
The EU RoHS Directive (2002/95/EC of the European Parliament and of the Council) bans the placing of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants on the EU market. It necessitates methods for the evaluation of RoHS compliance of assembled electronic equipment. In this study mounted printed circuit boards from personal computers were analyzed on their content of the three elements Cd, Pb and Hg which were limited by the EU RoHS directive. Main focus of the investigations was the influence of sample pre-treatment on the precision and reproducibility of the results. The sample preparation steps used were based on the guidelines given in EN 62321. Five different types of dissolution procedures were tested on different subsequent steps of sample treatment like cutting and milling. Elemental analysis was carried out using ICP–OES, XRF and CV–AFS (Hg). The results obtained showed that for decision-making with respect to RoHS compliance a size reduction of the material to be analyzed to particles ≤1.5 mm can already be sufficient. However, to ensure analytical results with relative standard deviations of less than 20%, as recommended by the EN 62321, a much larger effort for sample processing towards smaller particle sizes might be required which strongly depends on the mass fraction of the element under investigation.