During the last decades, X-ray (micro-)computed tomography has gained increasing attention for the description of porous skeletal and shell structures of various organism groups. However, their quantitative analysis is often hampered by the difficulty to discriminate cavities and pores within the object from the surrounding region. Herein, we test the ambient occlusion (AO) algorithm and newly implemented optimisations for the segmentation of cavities (implemented in the software Amira). The segmentation accuracy is evaluated as a function of (i) changes in the ray length input variable, and (ii) the usage of AO (scalar) field and other AO-derived (scalar) fields. The results clearly indicate that the AO field itself outperforms all other AO-derived fields in terms of segmentation accuracy and robustness against variations in the ray length input variable. The newly implemented optimisations improved the AO field-based segmentation only slightly, while the segmentations based on the AOderived fields improved considerably.
Additionally, we evaluated the potential of the AO field and AO-derived fields for the separation and classification of cavities as well as skeletal structures by comparing them with commonly used distance-map-based segmentations. For this, we tested the zooid separation within a bryozoan colony, the stereom classification of an ophiuroid tooth, the separation of bioerosion traces within a marble block and the calice (central cavity)-pore separation within a dendrophyllid coral. The obtained results clearly indicate that the ideal input field depends on the three-dimensional morphology of the object of interest. The segmentations based on the AO-derived fields often provided cavity separations and skeleton classifications that were superior to or impossible to obtain with commonly used distance-map-based segmentations. The combined usage of various AO-derived fields by supervised or unsupervised segmentation algorithms might provide a promising target for future research to further improve the results for this kind of high-end data segmentation and classification. Furthermore, the application of the developed segmentation algorithm is not restricted to X-ray (micro-)computed tomographic data but may potentially be useful for the segmentation of 3D volume data from other sources.
Der rekonstruierte CT-Datensatz liefert Informationen über die Dichteverteilung im Untersuchungsobjekt in Form einer Grauwertedarstellung. Zur quantitativen Bestimmung der anhand der Grauwertunterschiede separierbaren Strukturen bedarf es einer genauen Determinierung der diese Strukturen abgrenzenden Übergänge. Am Beispiel der Oberflächenbestimmung an einer Stahlbetonprobe wird der Unterschied zwischen globalem und lokalem Schwellwert gezeigt. Die so erzeugten Oberflächen dienen dem dimensionellen Messen innerhalb des CT-Datensatzes, dem Fitten von Regelgeometrien oder der Durchführung automatischer Analysen (Poren, Wandstäken, Faserorientierung). Zur Reduzierung der Datenmenge und zur Verwendung in Simulationsprogrammen können die gefundenen Oberflächen auch in ein Netzmodell überführt werden. Gezeigt wird der Einsatz dieser Techniken an Untersuchungen von Betonproben in der BAM.
Currently, mandatory requirements and recommendations for the detection of irregularities in laser beam welded joints are based on classic micrographs as set out in the standard ISO 13919-1:2019. Compared to classic micrographs, computed tomography enables a non-destructive, three-dimensional and material-independent mode of operation, which delivers much more profound results. Even in building material testing, methods with limited informative value can be checked and supplemented by CT examinations.
Different imaging techniques were employed to monitor Full Notch Creep Test (FNCT) experiments addressing environmental stress cracking in more detail. The FNCT is a well-established test method to assess slow crack growth and environmental stress cracking of polymer materials, especially polyethylene. The standard test procedure, as specified in ISO 16770, provides a simple comparative measure of the resistance to crack growth of a certain material based on the overall time to failure when loaded with a well-defined mechanical stress and immersed in a liquid medium promoting crack propagation.
Destructive techniques which require a direct view on the free fracture surface, such as light microscopy and laser scanning microscopy, are compared to non-destructive techniques, i.e. scanning acoustic microscopy and xray micro computed tomography. All methods allow the determination of an effective crack length. Based on a series of FNCT specimens progressively damaged for varied Durations under standard test conditions, the estimation of crack propagation rates is also enabled. Despite systematic deviations related to the respective Imaging techniques, this nevertheless provides a valuable tool for the detailed evaluation of the FNCT and its further development.
In der anthropologischen Rudolf-Virchow-Sammlung der Berliner Gesellschaft für Anthropologie, Ethnologie und Urgeschichte (BGAEU) befindet sich eine größere Anzahl menschlicher Schädel aus dem Gebiet des heutigen Lettlands, die Mehrzahl dabei von der im Norden Lettlands am Burtnieksee gelegenen Fundstelle Riņņukalns. Der nachfolgende Aufsatz beschreibt die Gründe, warum diese Stücke in den 1870er Jahren in die Sammlung gelangt sind, und präsentiert eine anthropologische Dokumentation und Analyse der Schädelfunde vom Riņņukalns aus der Sammlung.
Targeting biomedical applications, Triply Periodic Minimal Surface (TPMS) gyroid sheet-based structures were successfully manufactured for the first time by Electron Beam Melting in two different production Themes, i.e., inputting a zero (Wafer Theme) and a 200 µm (Melt Theme) wall thickness. Initial assumption was that in both cases, EBM manufacturing should yield the structures with similar mechanical properties as in a Wafer-mode, as wall thickness is determined by the minimal beam spot size of ca 200 µm. Their surface morphology, geometry, and mechanical properties were investigated by means of electron microscopy (SEM), X-ray Computed Tomography (XCT), and uniaxial tests (both compression and tension). Application of different manufacturing Themes resulted in specimens with different wall thicknesses while quasi-elastic gradients for different Themes was found to be of 1.5 GPa, similar to the elastic modulus of human cortical bone tissue. The specific energy absorption at 50% strain was also similar for the two types of structures. Finite element simulations were also conducted to qualitatively analyze the deformation process and the stress distribution under mechanical load. Simulations demonstrated that in the elastic regime wall, regions oriented parallel to the load are primarily affected by deformation. We could conclude that gyroids manufactured in Wafer and Melt Themes are equally effective in mimicking mechanical properties of the bones.
Mikrofokus-Röntgenquellen werden in der industriellen CT flexibelverwendet, um mit kleiner Leistung hohe Auflösung zu erzielen oder mit verminderter Auflösung bei höherer Leistung kürzere Messzeiten zu erreichen. Insbesondere Quellen in offener Bauweise benötigen Wartung wie Filamentwechsel und Nachstellen der Fokusparameter. Ziel ist es, einen optimal kleinen Quellfleck bei bekannter Spannung einzustellen und dessen Größe zu bestimmen.
Zur Überprüfung der Quellfleckgröße sind bereits Verfahren unter Verwendung lithographisch hergestellter Masken mit Strichmustern oder Siemenssternen aus Mikrometer dünnen Schichten aus stark absorbierendem Material wie z.B. Gold bekannt. Diese erfordern wegen der geringen Absorption eine lange Messzeit und sind nur kostenintensiv herzustellen. Ihre Verwendung zur regelmäßigen Qualitätsüberprüfung von CT-Anlagen ist daher nicht verbreitet.
Ziel dieser Arbeit ist es, die richtungsabhängige Quellfleckgröße absolut zu bestimmen, wobei nur einfach zu beschaffende Wolframspitzen verwendet werden. Dazu werden radiographische Bilder in hoher Vergrößerung aufgenommen und die Grauwertverteilung parametrisiert. Unter Verwendung der Kenntnis von Targetmaterial und Spannung wird eine eineindeutige Zuordnung zur Quellfleckgröße vorgenommen.
Dieses erfordert eine extensive Simulation für verschiedene Spannungen, Fokusgrößen und andere Einflussgrößen, sowie die experimentelle Verifikation an verschiedenen CT-Anlagen im Vergleich zu einer bekannten Methode. Erste Ergebnisse werden vorgestellt und die praktische Implementierung unter Angabe der Einschränkungen der Verwendbarkeit diskutiert. Die Autoren hoffen, damit einen wesentlichen Beitrag zur Verbesserung der Qualitätssicherung und zur
Arbeitseffizienz in der Mikrocomputertomographie leisten zu können.
The impact of fracture geometry and aperture distribution on fluid movement and on non-reactive solute transport was investigated experimentally and numerically in single fractures. For this purpose a hydrothermally altered and an unaltered granite drill core with axial fractures were investigated. Using three injection and three extraction locations at top and bottom of the fractured cores, different dipole flow fields were examined. The conservative tracer (Amino-G) breakthrough curves were measured using fluorescence spectroscopy. Based on 3-D digital data obtained by micro-computed tomography 2.5-D numerical models were generated for both fractures by mapping the measured aperture distributions to the 2-D fracture geometries (x-y plane). Fluid flow and tracer transport were simulated using COMSOL Multiphysics®.
By means of numerical simulations and tomographic imaging experimentally observed breakthrough curves can be understood and qualitatively reproduced. The experiments and simulations suggest that fluid flow in the altered fracture is governed by the 2-D fracture geometry in the x-y plane, while fluid flow in the unaltered fracture seems to be controlled by the aperture distribution. Moreover, we demonstrate that in our case simplified parallel-plate models fail to describe the experimental findings and that pronounced tailings can be attributed to complex internal heterogeneities. The results presented, implicate the necessity to incorporate complex domain geometries governing fluid flow and mass transport into transport modeling.
Functionally graded porous scaffolds (FGPS) constructed with pores of different size arranged as spatially continuous structure based on sheet-based gyroid with three different scaling factors of 0.05, 0.1 and 0.2 were produced by electron beam powder bed fusion. The pore dimensions of the obtained scaffolds satisfy the values required for optimal bone tissue ingrowth. Agglomerates of residual powder were found inside all structures, which required post-manufacturing treatment. Using X-ray Computed Tomography powder agglomerations were visualized and average wall thickness, wall-to-wall distances, micro- and macro-porosities were evaluated. The initial cleaning by powder recovery system (PRS) was insufficient for complete powder removal. Additional treatment by dry ultrasonic vibration (USV) was applied and was found successful for gyroids with the scaling factors of 0.05 and 0.1. Mechanical properties of the samples, including quasi-elastic gradients and first maximum compressive strengths of the structures before and after USV were evaluated to prove that additional treatment does not produce structural damage. The estimated quasi-elastic gradients for gyroids with different scaling factors lie in a range between 2.5 and 2.9 GPa, while the first maximum compressive strength vary from 52.5 for to 59.8 MPa, compressive offset stress vary from 46.2 for to 53.2 MPa.
The osseointegration in/around additively manufactured (AM) lattice structures of a new titanium alloy, Ti–19Nb–14Zr, was evaluated. Different lattices with increasingly high sidewalls gradually closing them were manufactured and implanted in sheep. After removal, the bone–interface implant (BII) and bone–implant contact (BIC) were studied from 3D X-ray computed tomography images. Measured BII of less than 10 µm and BIC of 95% are evidence of excellent osseointegration.
Since AMnaturally leads to a high-roughness surface finish, the wettability of the implant is increased.
The new alloy possesses an increased affinity to the bone. The lattice provides crevices in which the biological tissue can jump in and cling. The combination of these factors is pushing ossification beyond its natural limits. Therefore, the quality and speed of the ossification and osseointegration in/around these Ti–19Nb–14Zr laterally closed lattice implants open the possibility of bone spline key of prostheses. This enables the stabilization of the implant into the bone while keeping the possibility of punctual hooks allowing the implant to be removed more easily if required. Thus, this new titanium alloy and such laterally closed lattice structures are appropriate candidates to be implemented in a new generation of implants.