The International Temperature Scale of 1990 (ITS-90) is based on thermodynamic equilibrium states of ideally pure substances. The largest contribution to the uncertainty budgets of most metallic fixed points is the influence of impurities on the fixed-point temperature. Therefore, a traceable chemical analysis of the remaining impurities with small uncertainty is the basis of further progress. Further requirements are better knowledge of the phase diagrams at very low impurity contents, impurity segregation, and the quantification and correction of thermal effects during a fixed-point realization. In this article, current and future activities at PTB and BAM in order to develop improved metallic fixed-point cells of the ITS-90 are reviewed.
Determining the influence of impurities on the fixed-point emperatures
of the ITS-90 requires the completion of several tasks. In this paper, the Progress made at Physikalisch-Technische Bundesanstalt (PTB) and BAMFederal Institute for Materials Research and Testing is presented and remaining questions are discussed.
The projected characterization procedure at PTB, which is based on the established SIE method (sum of the individual estimates), using a new indium fixed-point cell is described as an example. This procedure includes an SI-traceable chemical Analysis of the material in the fixed-point cell with sufficiently low uncertainties, the individual experimental determination of the influence of the quantified impurities on the fixed-point temperature, and the establishment of direct links to the phase-transition temperatures of the national standard and of an assumed material of ideal purity.
A characteristic difference to the common practice is the chemical analysis of the fixed-point metal being done after determining the cells freezing temperature. This allows for the detection and consideration of contamination and purification effects due to the filling process, or due to the contact with the carbon crucible and other parts of the fixed-point cell. A chemical analysis of an indium fixed-point was carried out by BAM with relative measurement uncertainties below 30 % which have not been previously achieved. The results provide evidence for the precipitation of some impurities,
which is apparently inconsistent with the corresponding binary phase diagrams, but was explained in a recent publication. Implications for the use of the SIE method shall be described briefly at the end.
Within the scope of a project of the 'European Association of National Metrology Institutes' (EURAMET), a European metrological dissemination System (network) providing traceable reference values assigned to matrix materials for validation purposes is described and put to the test. It enables testing laboratories (TL) to obtain comparable results for measurements under the 'EU Water Framework Directive 2000/60/EC' (WFD) and thus, to comply with a core requirement of this very directive. The dissemination system is characterized by the fact that it is available to all laboratories throughout Europe which intend to perform measurements in the context of the WFD and that it can ensure sustainable metrological traceability to the International System of Units (SI) as a reference point for the measurement results. This Dissemination system is set up in a hierarchical manner and links up the level of the national metrology institutes (NMI) with that of the TLs via an intermediate level of calibration laboratories (CL) by comparison measurements. The CLs are expert laboratories with respect to the measurement of the analytes considered here (within the project, the CLs are called potential calibration laboratories (PCL)) and are additionally involved in the organization of comparison measurements within the scope of regional quality assurance (QA) systems.
Three comparison measurements have been performed to support the approach. A total of about 130 laboratories participated in this exercise with the focus on the measurement of the priority substances Pb, Cd, Hg, and Ni defined in the WFD. The elemental concentrations in the water samples roughly corresponded to one of the established environmental quality standards (EQS), the annual average concentration (AA-EQS), which is defined in the daughter Directive 2008/105/EC of the WFD. It turned out that a significant number of TLs still need to improve their measurement methods in order to be able to fulfill the Minimum requirements of the WFD, in particular, with regard to the elements Cd and Hg probably due to their low EQS values.
Furthermore, it became obvious that the hierarchical Dissemination system suggested here actually corresponds to the measuring capabilities of the three participating Groups (NMIs, PCLs, and TLs).
In this work, different calibration strategies for the determination of trace elements in pure copper metal by nanosecond laser ablation ICP-MS were investigated. In addition to certified reference materials (CRMs), pellets of doped copper powder were used for calibration. The micro homogeneity of the CRMs as well as the solution-doped pellets was sufficient to use them as calibration samples in combination with a laser spot size of 200 µm. In contrast, pellets doped with analytes in solid form showed a significant heterogeneity. For most of the investigated analytes and copper CRMs the measured mass fractions were within ± 20% of their certified values when other copper CRMs were used as calibration samples. When solution-doped powder pellets were used as calibration samples a systematic trend towards mass fractions below the certified values was observed for nearly all elements determined in the analysed CRMs. Thermal fractionation effects during the ablation of the solution-doped pellets were suspected as the extent of the fractionation depends on the irradiance, whereas fractionation is reduced at higher irradiance.
Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions.
Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated.
A candidate material for the use as primary standard for silver determination was characterized with respect to total purity. Except the radioactive elements and He, all possible impurities were considered. Based on glow discharge mass spectrometry, inductively coupled plasma-mass spectrometry and carrier gas hot extraction measurements, the demonstrated total purity and its standard uncertainty is w(Ag) = (99.999 52 ± 0.000 11) %. The purity value and its uncertainty is dominated by the contributions from the measurements of the nonmetallic impurities, namely S, N, C and O.