Inspired by the globule arc technique a new electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV-ICP OES) method was developed for the analysis of high-purity copper materials. The performance of the method was investigated for the analytes Ag, Al, As, Bi, Cd, Co, Cr, Fe, Mg, Mn, Ni, P, Pb, S, Sb, Se, Si, Sn, Te, Ti, Zn and Zr. ETV parameters were optimized regarding the release of the analytes, the transport efficiency and the quality of analytical results in terms of precision, trueness and power of detection. The influence of CCl2F2, CHClF2, C2H2F4 and CHF3 as gaseous halogenation modifiers was investigated. A sufficient in situ analyte matrix separation was achieved by using CHF3 as halogenating reagent avoiding a high matrix input from the molten copper sample into the ETV system and the plasma. A complete release from the samples was obtained for all investigated analytes except Se and Te. Acceptable results for the determination of the trace elements Ag, Al, As, Bi, Cd, Co, Cr, Fe, Mg, Mn, Ni, P, Pb, S, Sb, Si, Sn, Ti, Zn and Zr in high-purity copper were achieved. The method includes a preceding sample preparation step of oxidizing the surface of copper samples which results in a significantly enhanced sensitivity. In addition to the calibration with copper samples, the feasibility of the calibration with liquid multi-element solutions was investigated. Except for Ag, Mg and Ni all analytes could be analyzed using aqueous calibration solutions. The trueness of the method was tested by the determination of analyte contents of certified reference materials. Limits of quantification ranging from 0.6 ng g-1 to 29 ng g-1 were achieved. The developed direct solid sampling method is time and cost effective and well suited for the characterization of high-purity copper materials. The method can be automated to a large extent and is applicable for processes accompanying analyses. In contrast to all other investigated trace elements, Se and Te were not released from the matrix at measurable levels under the used conditions. The determination of these elements is still under investigation and will be reported in a succeeding publication.
In Germany a system of primary amount of substance standards for elemental analysis is being developed, which forms the material´s basis for the National Standards for element determination. The metrological concept and technical approach is briefly described. The objective of traceability in chemistry, in this case for elemental determination, is illustrated on the example of copper.
Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions.
Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated.