Filtern
Dokumenttyp
Sprache
- Englisch (13) (entfernen)
Schlagworte
- Computed tomography (6)
- Electron tomography (5)
- Iterative reconstruction (3)
- Neutron tomography (3)
- Tomography (3)
- Catalyst (2)
- DIRECTT (2)
- Fuel cell (2)
- Gas diffusion layer (GDL) (2)
- Magnetic domains (2)
A strategy to mitigate typical reconstruction artefacts in missing wedge computed tomography is presented. These artefacts appear as elongations of reconstructed details along the mean direction (i.e. the symmetry centre of the projections). Although absent in standard computed tomography applications, they are most prominent in advanced electron tomography and also in special topics of X-ray and Neutron tomography under restricted geometric boundary conditions. We investigate the Performance of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm to reduce the directional artefacts in standard procedures. In order to be sensitive to the anisotropic nature of missing wedge artefacts, we investigate isotropic substructures of metal foam as well as circular disc models. Comparison is drawn to filtered backprojection and algebraic techniques. Reference is made to reconstructions of complete data sets. For the purpose of assessing the reconstruction Quality, Fourier transforms are employed to visualize the missing wedge directly. Deficient reconstructions of disc models are evaluated by a length-weighted boundary orientations. The DIRECTT results are assessd at different signal-to-noise ratios by means of local and integral evaluation Parameters.
We present an experimental approach to study the three-dimensional microstructure of gas diffusion layer (GDL) materials under realistic compression conditions. A dedicated compression device was designed that allows for synchrotron-tomographic investigation of circular samples under well-defined compression conditions. The tomographic data provide the experimental basis for stochastic modeling of nonwoven GDL materials. A plain compression tool is used to study the fiber courses in the material at different compression stages. Transport relevant geometrical parameters, such as porosity, pore size, and tortuosity distributions, are exemplarily evaluated for a GDL sample in the uncompressed state and for a compression of 30 vol.%. To mimic the geometry of the flow-field, we employed a compression punch with an integrated channel-rib-profile. It turned out that the GDL material is homogeneously compressed under the ribs, however, much less compressed underneath the channel. GDL fibers extend far into the channel volume where they might interfere with the convective gas transport and the removal of liquid water from the cell.
This paper gives a brief overview on3D imaging of magnetic domains with shearing grating neutron tomography. We investigated the three-dimensional distribution of magnetic domain walls in the bulk of a wedge-shaped FeSi single crystal. The width of the magnetic domains wasanalyzed at different locations within the crystal. Magnetic domains close to the tip of the wedge are much smaller than in the bulk. Furthermore, the three-dimensional shape of individual domains wasinvestigated. We discuss prospects and limitations of the applied measurement technique.
The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography
reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.
We present a synchrotron X-ray tomographic study on the morphology of carbon fiber-based gas diffusion layer (GDL) material under compression. A dedicated compression device is used to provide well-defined compression conditions. A flat compression punch is employed to study the fiber geometry at different degrees of compression. Transport relevant geometrical parameters such as porosity, pore size and tortuosity distributions are calculated. The geometric properties notably change upon compression which has direct impact on transport conditions for gas and fluid flow. The availability of broad 3D paths, which are most important for the transport of liquid water from the catalyst layer through the GDL, is markedly reduced after compression. In a second experiment, we study the influence of the channel-land-pattern of the flow-field on shape and microstructure of the GDL. A flow-field compression punch is employed to reproduce the inhomogeneous compression conditions found during fuel cell assembly. While homogenously compressed underneath the land the GDL is much less and inhomogeneously compressed under the channel. The GDL material extends far into the channel volume where it can considerably influence gas and fluid flow. Loose fiber endings penetrate deeply into the channel and form obstacles for the discharge of liquid water droplets.
X-ray compton tomography
(2014)
The potentials of incoherent X-ray Scattering (Compton) tomography are investigated. Imaging materials of very different density or atomic number at once is a perpetual challenge for X-ray tomography or radiography, in general. In a basic laboratory set-up for simultaneous perpendicular Compton Scattering and direct beam attenuation tomographic scans are conducted by single channel photon counting. This results in asymmetric distortions of the projection profiles of the scattering CT-data set. ln a first approach corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts.
A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials.
Compärison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT bears the potential to replace neutron tomography, which requires much more efforts.
Neutron tomography was applied to study the 3D water distribution in full polymer electrolyte membrane fuel cell (PEMFC) stacks. The water distribution after switch-off of the fuel cell was analyzed over a period of 36 h. We found a slowly increasing water amount in the fuel cell, but only few changes within a time period of 5 h, which is about the time necessary for neutron tomography. In this way, the requirement for successful tomography was obtained. It is demonstrated how the quasi in-situ tomography technique enables us to study the water content in individual flow field channels of three-fold stacks. Flow field as well as stack design issues are addressed by this visualization method showing weak points due to a non-uniform water distribution that can be identified by means of neutron imaging.
In order to demonstrate the challenging tasks in current R&D applications in the field of renewable energy
sources experimental neutron and electron tomographic data sets of PEM fuel cell components are processed by
an advanced version of the DIRECTT algorithm. The neutron measurements of the water distribution suffer from
several intrinsic limitations such as massive position dependent focal smearing due to the large primary neutron
beam aperture. Electron (TEM) tomography allows characterisation of nanometre sized catalyst particles but is
hampered by the following restrictions: partial opacity, a limited sector of projections (missing wedge), very few
projections, samples exceeding the detector size (region of interest) and improper angular alignment. Beyond the
capabilities of other algorithms DIRECTT proves to overcome these essential reconstruction problems, in
comparison to FBP and SIRT. Nevertheless, careful data pre-processing is an inevitable requirement in order to
fully exploit the algorithm's potentials.
Incomplete tomographic data sets such as limited view (missing wedge) data represent a well-known challenge
for reconstruction algorithms, since they unavoidably lead to substantial image artefacts. Such data sets may
occur in industrial computed tomography of limited access (e.g. extended components, fixed objects), directional
opacity, limited sample life time or laminographic set-up. We present strategies to effectively suppress the
typical elongation artefacts (e.g. lemon-like deformed pores) by our iterative algorithm DIRECTT which offers
the opportunity to vary the versatile reconstruction parameters within each cycle. Those strategies are applied to
experimental data obtained from metallic foams as well as model simulations. Comparison is drawn to state-ofthe-
art techniques (filtered backprojection and algebraic techniques). Further reference is made to reconstructions
of complete data sets serving as gold standards. For quantitative assessment of the reconstruction
quality adapted techniques based on spatial statistics are introduced.
Tomography data obtained from transmission electron microscopes are especially attractive due to their unrivaled spatial resolution in the nanometer range or even less, but they require enormous efforts in sample preparation and suffer from a diverse accumulation of experimental restrictions, which unavoidably result in fundamental reconstruction artifacts. These restrictions refer to: partial opacity, a limited view (limited angle or missing wedge), very few angles (with respect to the detector size), limited to a region of interest (ROI; due to the sample size), variable angular increments as well as sample degradation due the interactions with the electron beam. An advanced version of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm proves to cope with most of these severe deviations from ideal CT measuring conditions. However, careful data preprocessing is required in order to exploit the capabilities of the algorithm.
Nanometer sized Ruthenium catalyst particles for fuel cell applications are 3D imaged at a few Ångström resolution in order to estimate their partial free surface on carbon black supports, which rule the efficiency of the catalytic activity.
Comparisons of DIRECTT reconstructions to the conventional filtered back projection, prove the significant improvements.