Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (65) (entfernen)
Schlagworte
- Tomography (8)
- Neutron imaging (7)
- Radiography (7)
- Water transport (7)
- Computed tomography (6)
- Electron tomography (6)
- Neutron tomography (6)
- Polymer electrolyte membrane fuel cell (PEMFC) (6)
- Fuel cell (5)
- Reconstruction algorithm (5)
- X-ray imaging (5)
- Catalyst (4)
- Neutron radiography (4)
- Gas diffusion layer (GDL) (3)
- Local current distribution (3)
- Synchrotron (3)
- Brennstoffzellen (2)
- Computertomographie (2)
- DIRECTT (2)
- Darkfield imaging (2)
- Elektronentomographie (2)
- Gas diffusion layer (2)
- Gas diffusion layers (2)
- HT-PEFC (2)
- Hydrogen diffusion (2)
- Hydrogen embrittlement (2)
- Magnetic domains (2)
- Missing wedge (2)
- PEM fuel cell (2)
- Phase distribution (2)
- Phase transformation (2)
- Phosphoric acid (2)
- Resolution neutron-radiography (2)
- Solid electrolytes (2)
- Solid-state batteries (2)
- Synchrotron X-ray imaging (2)
- Synchrotron X-ray tomography (2)
- Synchrotron radiography (2)
- Water management (2)
- X-ray compton scattering (2)
- 2D/3D imageanalysis (1)
- 3D image analysis (1)
- 3D imaging (1)
- 4D tomographic data (1)
- Aging mechanism (1)
- Algorithm (1)
- Alkali metal anodes (1)
- Alkali metal batteries (1)
- All-solid-state batteries (1)
- Attenuation coefficient (1)
- BAMline (1)
- Backlighting (1)
- Batteries (1)
- Battery failure mechanisms (1)
- Blister (1)
- Bragg-edge (1)
- Bragg-edge imaging (1)
- Brennstoffzelle (1)
- Carbon dioxide evolution (1)
- Carbon-dioxide (1)
- Catalyst Layer (1)
- Cathode deactivation (1)
- Cells (1)
- Codependent failure mechanism (1)
- Compression (1)
- Compression device (1)
- Compression effect (1)
- Computertomographie (CT) (1)
- Copper sulfide (1)
- Crack evolution (1)
- Crack formation (1)
- Cross section (1)
- Current density distribution (1)
- DMFC (1)
- Debye–Waller factor (1)
- Degradation (1)
- Diffraction contrast neutron imaging (1)
- Diffusion (1)
- Digital detector array (1)
- Digital volume correlation (1)
- Direct methanol fuel cell (1)
- Direct methanol fuel cells (1)
- Edge tomography (1)
- Electrochemical impedance spectra (1)
- Fiber composites (1)
- Fuel cell stack (1)
- Full-field phase tomography (1)
- Gas diffusion electrodes (1)
- Geometrical effect (1)
- Geometrical tortuosity (1)
- Grating interferometry (1)
- Hydrogen (1)
- Hydrophobic treatment (1)
- Image morphology (1)
- Imaging (1)
- In situ (1)
- In situ study (1)
- In-Situ-Radiologie (1)
- In-situ characterization of GDLs (1)
- In-situ synchrotron X-ray computed tomography (1)
- In-situ synchrotron X-ray radiography (1)
- Instrumentation for neutron sources (1)
- Iron (1)
- Iterative Rekonstruktion (1)
- Iterative reconstruction (1)
- LSW (1)
- Laser powder-bed fusion (1)
- Lattice Boltzmann simulation (1)
- Li composite electrode (1)
- Li dendrites (1)
- Li dendrites penetration mechanisms (1)
- Li metal batteries (1)
- Li-B-Mg (1)
- LiS battery (1)
- Liquid water (1)
- Liquid water flow rate (1)
- Lithium ion flux (1)
- Lithium metal batteries (1)
- Lithium/sodium−carbon dioxide batteries (1)
- Manifold stack (1)
- Materialcharakterisierung (1)
- Membrane electrode assembly (1)
- Membrane electrode assembly (MEA) (1)
- Metal foam microstructure (1)
- Methanol (1)
- Micro-tomography (1)
- Microporous Layer (1)
- Microporous layer (MPL) (1)
- Microstructure (1)
- Microtomography (1)
- Multi-energy CT (1)
- NaO-battery (1)
- Neutron Bragg edge imaging (1)
- Neutron computed tomography (1)
- Neutron detectors (cold, thermal, fast neutrons) (1)
- Neutron imaging technique (1)
- Neutron scattering (1)
- Neutronen-Radiographie (1)
- Neutronen-Tomographie (1)
- Neutronenlaminographie (1)
- Neutronentomographie (1)
- Neutrons (1)
- Nneutron imaging (1)
- Non-destructive testing (1)
- Operando cell (1)
- Oxidation (1)
- PEM Fuel-cells (1)
- Perforated gas diffusion layer (GDL) (1)
- Platinum (1)
- Polycromatic neutrons (1)
- Polymer Electrolyte Membrane Fuel Cell (1)
- Polymer electrolyte membrane fuel cell (1)
- Pore size analysis (1)
- Preferential orientation (1)
- Primary Battery (1)
- PtRu corrosion (1)
- Quantification (1)
- Radiology (1)
- Reconstruction (1)
- Reconstruction algrorithm (1)
- Rectangular cross-section (1)
- Rekonstruktionsalgorithmus (1)
- Rock porosity (1)
- Ruthenium distribution (1)
- Scintillator (1)
- Shearing gratings (1)
- Solid-state lithium metal batteries (1)
- Spectral CT (1)
- Statistische Bewertung (1)
- Steel (1)
- Stromdichtemessung (1)
- Sulfide solid electrolytes (1)
- Super martensitic stainless steel (1)
- Synchrotron Imaging (1)
- Synchrotron Tomography (1)
- Synchrotron X-Ray (1)
- Synchrotron X-ray (1)
- Synchrotron X-ray computed tomography (1)
- Synchrotron radiation (1)
- Synchrotron tomography (1)
- Synchrotron x-ray radiography (1)
- Synchrotronstrahlung (1)
- Talbot-Lau (1)
- Talbot-Lau interferometer (1)
- Talbot-Lau neutron tomography (1)
- Technical binary alloys (1)
- Temperature-dependent neutron transmission (1)
- Texture (1)
- Three-dimensional data quantification (1)
- Through-plane (1)
- Tomographic reconstruction (1)
- Tomographische Rekonstruktionsalgorithmen (1)
- Torsion (1)
- Tortuosity (1)
- Two-phase flow (1)
- Wassermanagement (1)
- Water Distribution (1)
- Water transport path (1)
- Water transport paths (1)
- X-Ray imaging (1)
- X-ray CT (1)
- X-ray computed tomography (1)
- X-ray energy edge (1)
- X-ray radiography (1)
- X-ray synchrotron radiography (1)
- X-ray tomography (1)
- XAS (1)
- Zerstörungsfrei (1)
- cold neutrons (1)
- iron embrittlement (1)
- neutron imaging (1)
- neutron instrumentation (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Ein effektives Wassermanagement ist ein wichtiger Aspekt in der Entwicklung von Brennstoffzellen hinsichtlich Langzeitstabilität und Optimierung der Leistungsfähigkeit. Eine zentrale Rolle spielt dabei die Gasdiffusionslage, die für die gleichmäßige Verteilung der Reaktionsgase auf die elektrochemisch aktive Schicht (Katalysator) sorgen soll. In diesem Beitrag werden gemeinsame Forschungsaktivitäten des Helmholtz-Zentrums Berlin für Materialien und Energie (Entwicklung bildgebender Verfahren) sowie des Zentrums für Sonnenenergie- und Wasserstoff-Forschung (ZSW, Entwicklung von Brennstoffzellen) vorgestellt. Im Rahmen dieser Kooperation werden die Entstehung, die Verteilung und der Transport von flüssigem Wasser, kurz das Wassermanagement, unter Betriebsbedingungen untersucht. Mittels Synchrotronradiografie und -tomografie werden kleinste Wassercluster in der Gasdiffusionslage detektiert. Die gewonnenen Erkenntnisse dienen der Modifikation und einer gezielten Auswahl der eingesetzten Materialien.
Rocks are commonly very heterogeneous materials. Randomly distributed micro-flaws inside the rock are believed to initiate tensile cracks from which shear fractures develop and coalescence through en echelon interactions leads to fracture. In this paper, we describe the results of applying high-resolution X-ray tomography to samples of greywacke and limestone experimentally deformed under unconfined axial shortening at various loads equivalent to different fractions of the sample strength. Mineral grains, pores, micro-cracks and other voids were imaged with a resolution of 10 µm. 3D image analysis enabled us to monitor the initial state of the samples and the changes in them due to compression. Crack morphology is characterized and compared to the micro-structure of the sample before and after deformation. In the greywacke, formation of a macro-crack ~10° oblique to the stress direction is observed. It initiated in fine intergranular material at the top tip of the sample and is composed of tensile fractures connected by wing cracks. None of the voids defined in the initial state fractured, and the crack is interpreted to have started either as a micro-crack which was smaller than the resolution of the tomography, or, as a completely new crack. In the limestone, cracks are observed to initiate in features that are too small to be imaged by the tomography, or also in newly created cracks.
Coarsening of grain-refined semi-solid Al-Ge32 alloy: X-ray microtomography and in situ radiography
(2007)
The carbon dioxide evolution and bubble formation in an operating fuel has been studied by means of synchrotron X-ray radiography. Two different observation directions have been chosen: a through-plane insight has been employed to track the formation of bubbles starting at the corner of the lands of the flow field; a depth profile of the carbon dioxide evolution has been derived from cross sectional studies describing an affected area of up to 100 µm. The dynamics of the bubble formation and detachment of the bubbles from the position of formation is strongly correlated with the current density. Cracks and breaks in the catalyst layer which result from the preparation process are visible under operating conditions and a possible swelling of the catalyst layer does not reach a complete vanishing of the cracks.
Die Aufklärung spezifischer Fragestellungen zur Funktionalität von PEM(polymer electrolyte membrane)- und DMFC(Direct Methanol)-Brennstoffzellen bedarf der 3D-Abbildung der spezifischen Komponenten mit unterschiedlichen Strahlungsarten: des Wassergehalts in den Flow Fields mit Neutronen, der Katalysator-Alterung in der MEA (membrane electrode assembly) mit Synchrotronstrahlung und der freien (reaktiven) Katalysator-Oberfläche von Nano-Partikeln mit TEM-Elektronen-Tomografie. Diese Messungen im Bereich der mm- bis nm-Skala unterliegen dabei erheblichen Restriktionen: einer ortsabhängigen Verschmierung der Neutronenradiogramme, Manipulatorinstabilitäten der Synchrotronmessungen sowie einer Kombination von Limited-View-Datensätzen, wenigen Projektionswinkeln und teilweiser Nichtdurchstrahlbarkeit in der Elektronen-CT. Die Vorteile eines fortentwickelten Directt-Algorithmus für die Bewältigung dieser Randbedingungen gegenüber gefilterten Rückprojektionen werden aufgezeigt.
Charakterisierung von Katalysatormaterialien für Brennstoffzellen mittels Elektronentomografie
(2010)
Zur Optimierung moderner Katalysatoren für Brennstoffzellen werden diese elektronen-tomografisch charakterisiert. Die Elektronentomografie ermöglicht einzigartige Einblicke in die Nanometer-Strukturen der metallischen Katalysatorpartikel, die auf einem elektrisch leitenden, inerten Kohlenstoffträger abgeschieden werden. Die dreidimensional bildgebende Methode ermöglicht über qualitative Untersuchungen hinaus detaillierte quantitative Form- und Strukturanalysen der Katalysatormaterialien. So werden beispielsweise die Positionen der Katalysatorpartikel relativ zum Trägermaterial analysiert. Ihre Form und Einbettung in den Träger, welche die für die katalytische Reaktion maßgebliche "freie Oberfläche" definieren, werden bestimmt. Die Elektronentomografie ermöglicht somit quantitative Vergleiche zwischen verschiedenen Katalysatormaterialien und Herstellungsverfahren. Sie erweitert die Möglichkeiten der Korrelation gewünschter elektrochemischer Eigenschaften mit der Nanostruktur dieser Materialien und macht so weitere Optimierungen der Katalysatormaterialien möglich.
In-situ-Neutronenradiografie wird erfolgreich eingesetzt, um flüssiges Wasser in Niedertemperatur-PEM-Brennstoffzellen während des Betriebs zerstörungsfrei abzubilden und das sogenannte Wassermanagement eine der größten Herausforderungen der Entwicklung durch Anpassung der Materialeigenschaften zu optimieren. Dabei werden die besonderen Eigenschaften der Neutronen genutzt, die metallische Bauteile relativ leicht durchdringen, während selbst kleine Wassermengen durch ihre starke Streuung leicht nachweisbar sind. Die relativ langen Messzeiten für die Neutronentomografie werden durch den Betrieb der Zelle im angehaltenen Zustand realisierbar, sodass die dreidimensionale Wasserverteilung darstellbar wird.
Magnetic domains have been the subject of much scientific investigation since their theoretical existence was first postulated by P.-E. Weiss over a century ago. Up to now, the three-dimensional (3D) domain structure of bulk magnets has never been observed owing to the lack of appropriate experimental methods. Domain analysis in bulk matter thus remains one of the most challenging tasks in research on magnetic materials. All current domain observation methods are limited to studying surface domains or thin magnetic films. As the properties of magnetic materials are strongly affected by their domain structure, the development of a technique capable of investigating the shape, size and distribution of individual domains in three dimensions is of great importance. Here, we show that the novel technique of Talbot-Lau neutron tomography with inverted geometry enables direct imaging of the 3D network of magnetic domains within the bulk of FeSi crystals.
Water transport in an operating PEM fuel cell was investigated with synchrotron X-ray radiography with a spatial resolution of 3 µm and a temporal resolution of 5 s. This method allows for the detection of water accumulations with less than 10 µm diameter. We demonstrate that synchrotron X-ray imaging can dramatically expand the possibilities of imaging with high spatial and time resolution, especially as a complement to neutron radiography. Water transport processes from the first appearance of small water accumulations in the gas diffusion layer to their transport into the channel system were analysed in situ. Correlations between local effects such as water formation and operating conditions of the whole system, e.g. power variations, were found. A recently described eruptive water transport mechanism is analysed in detail.
Influence of artificial aging of gas diffusion layers on the water management of PEM fuel cells
(2014)
The influence of artificial aging of gas diffusion layers (GDL) on the water management within the GDL was investigated in-operando by synchrotron X-ray radiography. One GDL was subjected to an accelerated aging procedure in 30% H2O2 solution, while another GDL was pristine. Radiographic measurements were combined with temporally resolved electrical analyzes. Significant differences in cell voltage and water accumulation were observed during cell operation at steady-state conditions. The cell which contained the aged GDL featured a higher water amount especially at the anode side and a lower cell voltage.