Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (142)
- Zeitschriftenartikel (77)
- Beitrag zu einem Tagungsband (35)
- Posterpräsentation (12)
- Buchkapitel (6)
- Forschungsbericht (4)
- Sonstiges (3)
- Beitrag zu einem Sammelband (2)
- Forschungsdatensatz (2)
- Monografie (1)
Sprache
- Deutsch (151)
- Englisch (134)
- Mehrsprachig (1)
Schlagworte
- Prozessanalytik (59)
- Online NMR Spectroscopy (36)
- Process Analytical Technology (36)
- Industrie 4.0 (34)
- Prozessindustrie (34)
- CONSENS (29)
- Process analytical technology (24)
- Online NMR spectroscopy (21)
- Reaction Monitoring (17)
- Digitalisierung (16)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (119)
- 1.4 Prozessanalytik (118)
- 8 Zerstörungsfreie Prüfung (14)
- 8.6 Faseroptische Sensorik (10)
- 6 Materialchemie (5)
- 8.0 Abteilungsleitung und andere (5)
- 6.3 Strukturanalytik (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 3 Gefahrgutumschließungen; Energiespeicher (3)
- 1.3 Instrumentelle Analytik (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (142)
Um die internationale Spitzenposition deutscher Unternehmen der Prozessindustrie auch in Zukunft sicher zu stellen, müssen die Unternehmen ihre Prozesse und Geschäftsabläufe digitalisieren und gemeinsam mit der Forschung innovative neue Methoden, Apparate, Anlagen, Sensoren und Automatisierungstechnik sowie Datenkonzepte entwickeln. All dies erfordert den Aufbau neuer Fähigkeiten, Investition in Talente, interdisziplinäre Kommunikation zwischen verschiedenen Personen und Abteilungen und eine Bereitschaft zur Veränderung.
Modular chemical production is a tangible implementation of the digital transformation of the specialty chemicals process industry. In particular, it enables acceleration of process development and thus faster time to market by flexibly interconnecting and orchestrating standardized physical modules and bringing them to life. For this purpose, specific (chemical) sensors of process analytics are needed, preferably without lengthy calibration or spectroscopic model development.
An excellent example of a "direct" analytical method is online nuclear magnetic resonance (NMR) spectroscopy. NMR spectroscopy meets the requirements of a direct analytical method because of the direct correlation between the signal area in the spectrum ("counting" the nuclear spins) and the analyte amount of substance concentrations. It is also extremely linear over the concentration range.
With the availability of compact benchtop NMR instruments, it is now possible to bring NMR spectroscopy directly into the field, in close proximity to specialized laboratory facilities, pilot plants, and even industrial-scale production facilities. The first systems are in TRL 8 (Qualified System with Proof of Functionality in the Field).
The presentation will discuss the many building blocks of online nuclear magnetic resonance spectroscopy, from flow cells to automated data analysis.
Cryoadsorption on the inner surface of porous materials is a promising solution for safe, fast, and reversible hydrogen storage. Within the class of highly porous metal−organic frameworks, zeolitic imidazolate frameworks (ZIFs) show high thermal, chemical, and mechanical stability. In this study, we selected ZIF-8 synthesized mechanochemically by twin-screw extrusion as powder and pellets. The hydrogen storage capacity at 77 K and up to 100 bar has been analyzed in two laboratories applying three different measurement setups showing a high reproducibility. Pelletizing ZIF-8 increases the packing density close to the corresponding value for a single crystal without loss of porosity, resulting in an improved volumetric hydrogen storage capacity close to the upper limit for a single crystal. The high volumetric uptake combined with a low and constant heat of adsorption provides ca. 31 g of usable hydrogen per liter of pellet assuming a temperature−pressure swing adsorption process between 77 K − 100 bar and 117 K − 5 bar. Cycling experiments do not indicate any degradation in storage capacity. The excellent stability during preparation, handling, and operation of ZIF-8 pellets demonstrates its potential as a robust adsorbent material for technical application in pilot- and full-scale adsorption vessel prototypes.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole. Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature. This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
Anhand von Beispielen wird in diesem Vortrag ein möglicher ganzheitlicherer Ansatz für die Digitalisierung und den Einsatz maschinengestützter Prozesse bei der Herstellung von Spezialchemikalien und Arzneimitteln durch die Einführung integrierter und vernetzter Systeme und Prozesse skizziert. Ein aktueller Ansatz und ein Beispiel in diesem Vortrag sind flexible und modulare chemische Produktionseinheiten, die Mehrzweckanlagen nutzen, um verschiedene hochwertige Produkte mit kurzen Stillstandszeiten zwischen den Kampagnen herzustellen und die Markteinführungszeit für neue Produkte zu verkürzen.
Als zweites Beispiel wird kurz die Testplattform Wasserstofftankstelle vorgestellt, die als moderne Anlage der Prozessindustrie betrachtet werden kann, vergleichbar mit einer Anlage aus der chemischen oder pharmazeutischen Industrie. An ihr lassen sich alle derzeit entlang der Digitalen Transformation diskutierten Konzepte implementieren, um sie zu standardisieren und zu validieren. Dazu gehören Konzepte zur Konnektivität von Sensoren und Aktoren aus der Feldebene in höhere Ebenen der Automatisierung oder zur Einbringung zusätzlicher Sensoren oder Sensornetzwerke, die zunehmend flexibler gestaltet werden soll, die sichere und nachvollziehbare Parametrierung von Automatisierungskomponenten – vielleicht aus einem digitalen Abbild (Verwaltungsschale bzw. „Digitaler Zwilling“) heraus, Konzepte zur vorausschauenden Wartung („Predictive Maintenance“), Konzepte zu digitalen Entscheidungsprozessen, Zertifikaten und Signaturen oder der zunehmende Einsatz von komplexen Auswertungsalgorithmen und Applikationen in der Feldebene („Embedded Computing“) oder der „Kante“ zu Cloudbasierten Systemen der Informationstechnik („Edge-Computing“).
Die beiden Beispiele sollen aktuelle Entwicklungsachsen des industriellen Messwesens im Rahmen der industriellen Automation aufzeigen, in denen Messwerte, deren Messunsicherheiten und Kontextinformationen eine wichtige Rolle einnehmen.
Establishing ZIF‐8 as a reference material for hydrogen cryoadsorption: An interlaboratory study
(2024)
AbstractHydrogen storage by cryoadsorption on porous materials has the advantages of low material cost, safety, fast kinetics, and high cyclic stability. The further development of this technology requires reliable data on the H2 uptake of the adsorbents, however, even for activated carbons the values between different laboratories show sometimes large discrepancies. So far no reference material for hydrogen cryoadsorption is available. The metal‐organic framework ZIF‐8 is an ideal material possessing high thermal, chemical, and mechanical stability that reduces degradation during handling and activation. Here, we distributed ZIF‐8 pellets synthesized by extrusion to 9 laboratories equipped with 15 different experimental setups including gravimetric and volumetric analyzers. The gravimetric H2 uptake of the pellets was measured at 77 K and up to 100 bar showing a high reproducibility between the different laboratories, with a small relative standard deviation of 3–4 % between pressures of 10–100 bar. The effect of operating variables like the amount of sample or analysis temperature was evaluated, remarking the calibration of devices and other correction procedures as the most significant deviation sources. Overall, the reproducible hydrogen cryoadsorption measurements indicate the robustness of the ZIF‐8 pellets, which we want to propose as a reference material.