Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (101)
- Beitrag zu einem Tagungsband (91)
- Beitrag zu einem Sammelband (67)
- Zeitschriftenartikel (15)
- Buchkapitel (13)
- Posterpräsentation (10)
- Sonstiges (3)
- Forschungsbericht (3)
- Corrigendum (1)
Sprache
- Deutsch (182)
- Englisch (121)
- Italienisch (1)
Referierte Publikation
- nein (304) (entfernen)
Schlagworte
- Radar (37)
- Aktive Thermografie (36)
- Active thermography (31)
- Non-destructive testing (24)
- Thermografie (19)
- Zerstörungsfreie Prüfung im Bauwesen (19)
- Concrete (18)
- Beton (15)
- Masonry (13)
- Thermography (13)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (21)
- 8.0 Abteilungsleitung und andere (21)
- 7 Bauwerkssicherheit (4)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (4)
- 8.4 Akustische und elektromagnetische Verfahren (3)
- 9 Komponentensicherheit (2)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.9 Chemische und optische Sensorik (1)
- 4 Material und Umwelt (1)
Eingeladener Vortrag
- nein (101)
Am Deutschen Dom wurden Mikrowellenabsorptionsmessungen, Radar und Infarot- Thermographie als moderne zerstörungsfreie Prüfverfahren der Feuchtemessung in Mauerwerk erprobt. Ergänzende numerische Simulationsrechnungen des gekoppelten Wärme- und Feuchtetransports sollen bei der Auswahl von Trockenlegungskonzepten helfen.
Active infrared thermography in civil engineering - quantitative analysis by numerical simulation
(2003)
The cooling-down process of building structures after heating-up with an external radiation source was analysed to detect voids inside and below the surface. Quantitative results of concrete test specimen containing voids with different sizes at various depths will be presented here. The experimental results were compared to numerical simulations performed with a Finite Difference program developed at BAM.
Anwendung der Impuls-Thermografie als quantitatives zerstörungsfreies Prüfverfahren im Bauwesen
(2002)
Zusammenfassung
Die Impuls-Thermografie ist eine aktive Methode zur Strukturuntersuchung von Bauteilen. Im Rahmen eines von der DFG geförderten Projektes wird in Kooperation mit der TU Berlin an der Bundesanstalt für Materialforschung und -prüfung zur Zeit die mögliche Anwendung der Impuls-Thermografie als zerstörungsfreies Prüfverfahren im Bauwesen untersucht.
Die Impuls-Thermografie soll zur Ortung von oberflächennahen Inhomogenitäten, bei denen es sich im Normalfall um Fehlstellen handelt, in typischen Bauteilen verwendet werden und nach Möglichkeit die Geometrie- sowie die Materialparameter der Inhomogenitäten quantitativ bestimmt werden.
Messungen werden derart durchgeführt, dass Oberflächen mit einem geeigneten Heizstrahler erwärmt, die anschließenden Abkühlungsprozesse mit einer Infrarot-Kamera betrachtet und thermische Bilddaten (Thermogramme) aufgezeichnet werden. Der Hauptansatzpunkt für die quantitative Auswertung der Messdaten ist die Betrachtung von Temperatur-Zeit-Kurven (Transienten) des Abkühlungsprozesses über fehlerfreien und fehlerhaften Bereichen des Probekörpers. Zusätzlich werden auf Basis der Finiten-Differenzen-Methode numerische Simulationen durchgeführt. Quantitative Ergebnisse werden sowohl durch den Vergleich der experimentellen Daten mit den Simulationsrechnungen als auch durch eine Anpassung analytischer Funktionen an die Transienten erzielt.
The application of impulse radar for structural investigation of concrete elements has been increased during the last years related to technical developments, i. e. of high frequency antennas. In this paper, case studies will be presented related to the location of reinforcing bars, tendon ducts and repaired concrete areas in concrete bridges, anchors and dowels in concrete highways and delaminations of layered structures as they are used for non-ballasted railway tracks. It is shown that impulse radar can be applied in case of regular inspection and for searching the cause of damages but also for quality assessment in civil engineering.
Application of georadar for the determination of moisture content and distribution in masonry
(2003)
For the investigation of the complex inner structure of historic buildings, the application of radar has been increased during the last ten years. Although historic masonry in general is very inhomogeneous and although in some cases high absorption occurs due to enhanced moisture, radar has been successfully applied to get information on geometry, position of inclusions and about kind and size of existing damages. In this paper case studies will be presented concerning the localisation of metallic inclusions and the investigations of the structure of an exterior wall with a multiple leaf structure.
Ortung von Hohlstellen und Ablösungen in Betonkonstruktionen mit Radar und Impuls-Thermografie
(2003)
We concentrate on appropriate algorithmic processing of microwave Ground Penetrating Radar (GPR) data obtained from concrete specimens containing tendon ducts below steel reinforcement bars either via simulations or via experiments. The goal is to understand the physical phenomena of electromagnetic wave propagation and scattering in detail in order to optimize imaging algorithms like SAFT (Synthetic Aperture Focusing Technique as the NDT version of SAR) in its 3D diffraction tomographic FT-SAFT formulation (Fourier-Transform-SAFT). Therefore we start with the simulation of a "simple" specimen and switch to a more realistic one in order to check whether simulation and experiment can give comparable results. Basically, this could be confirmed, but, nevertheless, various parametric studies will still have to be performed in the future.
ONSITEFORMASONRY is a research project funded by the European Commission under the 5. Framework Programme 1998-2002 in the Thematic Programme: Energy, Environment and Sustainable Development and the Key Action: The City of Tomorrow and Cultural Heritage.
The main objective of the project is the development and improvement of methodologies for the evaluation of the structure of historic masonry Cultural Heritages. For effective restoration and conservation of historic buildings, a detailed assessment of the structural safety and physical damages of the masonry structure is required. Therefore, typical masonry damages and the most frequent pathologies in each region have been identified and summarised in a catalogue of problems and damages. Selected non-destructive (NDT) and minor-destructive (MDT) techniques are performed by the partners including the development of software packages for fast and automated data analysis. The strategy for an effective and useful combination of different NDT and MDT methods will be worked out considering the results of case studies and taking into account the experiences of the consortium members. Recommendations and guidelines for the application of the integrated methodologies will be developed in close co-operation with end-users.