The majority of ultrasonic devices used for non-destructive testing in civil engineering require contact with the surface of the concrete (specimen), which significantly increases the time required for the measurement. This makes it impractical for extensive investigation of large-scale structures such as bridge decks, foundations, or tunnels.
In a pioneering approach, fluidic oscillators are used as contact free ultrasonic sources to overcome the aforementioned limitations. These robust and cost-effective actuators require only pressurised air and are ideally suited for harsh environments. At a constant supply pressure, they generate a continuous mono-frequent actuation signal. Further, varying the supply pressure via a fast pressure regulator was found to generate a frequency modulated signal which enabled time-of-flight measurement with an added advantage of increased signal to noise ratio. To demonstrate the feasibility of this novel idea of non-contact ultrasound, the results of the initial tests are presented.
The dataset presented contains ultrasonic data recorded in pulse echo mode. The investigated specimen is made of the isotropic homogeneous material polyamide and has a drill hole of constant diameter running parallel to the surface, which was scanned in a point grid using an automatic scanner system. At each measuring position, a pitch-catch measurement was performed using a sampling rate of 2 MHz. The probes used are arrays consisting of a spatially separated receiving and in-phase transmitting unit. The transmitting and receiving sides each consist of 12 point-shaped single probes. These dry-point contact (DPC) probes operate according to the piezoelectric principle at nominal frequencies of 55 kHz (shear waves) and 100 kHz (longitudinal waves), respectively, and do not require a coupling medium. The measurements are performed with longitudinal (100 kHz) and transverse (55 kHz) waves with different geometric orientations of the probe on the measurement surface. The data presented in the article provide a valid source for evaluating reconstruction algorithms for imaging in the low-frequency ultrasound range.
Ultrasonic testing is a widely applied measurement method in materials research and medicine. Commonly, a transducer is coupled to the specimen directly or via a liquid coupling agent. While reducing acoustic transmission losses significantly, this procedure is time-consuming and cannot be used for sensitive specimens. Air-coupled ultrasound is a viable alternative in such cases, although suffering from very high acoustic transmission losses between transducer, air and specimen. The recently introduced fluidic transducer (FT) generates ultrasound by utilizing the instability of a supersonic air jet switched inside a fluidic amplifier. Since only air is used as the working medium and no vibrating surfaces are used for ultrasound generation, the transducer is able to efficiently generate large acoustic pressure amplitudes. The resulting acoustic field shares its directivity with the ejected high-velocity air jet. Thus, the acoustic energy needs to be redirected from the jet axis in order to make the fluidic transducer applicable to sensitive specimens. In this study, the effectivity of using sonic crystals (SCs) for this redirection is investigated using acoustic and flow measurements. SCs are air-permeable while being reflective to large acoustic frequency bands. It was shown that both a defect waveguide and a mirroring strategy successfully redirected the acoustic field from the air jet. Furthermore, the interaction of flow and SC showed strong acoustic quenching if the SC was placed too close to the FT outlet. Blockage of the jet entrainment due to the SC may result in slightly higher off-axis flow velocities locally, which should be considered in sensitive applications.
Development of an Accurate and Robust Air-Coupled Ultrasonic Time-of-Flight Measurement Technique
(2022)
Ultrasonic time-of-flight (ToF) measurements enable the non-destructive characterization of material parameters as well as the reconstruction of scatterers inside a specimen. The time-consuming and potentially damaging procedure of applying a liquid couplant between specimen and transducer can be avoided by using air-coupled ultrasound. However, to obtain accurate ToF results, the waveform and travel time of the acoustic signal through the air, which are influenced by the ambient conditions, need to be considered. The placement of microphones as signal receivers is restricted to locations where they do not affect the sound field. This study presents a novel method for in-air ranging and ToF determination that is non-invasive and robust to changing ambient conditions or waveform variations. The in-air travel time was determined by utilizing the azimuthal directivity of a laser Doppler vibrometer operated in refracto-vibrometry (RV) mode. The time of entry of the acoustic signal was determined using the autocorrelation of the RV signal. The same signal was further used as a reference for determining the ToF through the specimen in transmission mode via cross-correlation. The derived signal processing procedure was verified in experiments on a polyamide specimen. Here, a ranging accuracy of <0.1 mm and a transmission ToF accuracy of 0.3μs were achieved. Thus, the proposed method enables fast and accurate non-invasive ToF measurements that do not require knowledge about transducer characteristics or ambient conditions.
Digitaler Zwilling: Verwaltungsschale BBox als Datenablage über den Lebenszyklus einer Brücke
(2021)
Auf dem Weg zur digitalen Brücke existieren bereits erste Lösungen, die den Lebenszyklus einer Brücke abbilden können. Für die Planung, den Bau und den Unterhalt stehen unterschiedlichste Werkzeuge, z. B. BIM, DIN 1076, SIB-Bauwerke, Monitoring etc. zur Verfügung, die jeweils mit unterschiedlichen Datenformaten arbeiten. Für ein intelligentes Erhaltungsmanagement müssen aber alle Daten mit den verschiedenen Datenformaten zusammengeführt, abgelegt und so verwaltet werden können, dass über den gesamten Lebenszyklus einer Brücke die Abbildung eines ganzheitlichen digitalen Zwillings eines Bauwerks möglich ist. Die Autoren haben dafür mit BBox den Prototyp einer Verwaltungsschale (VWS) auf Grundlage von Industrie 4.0 entwickelt. Damit wird das physikalisch-ingenieurtechnische Modell zur Zustandsbewertung der Brücke in den Mittelpunkt gestellt und der gesamte Lebenszyklus einer Brücke kann unabhängig von Datenformaten digital erfasst werden. Da der Aufbau der VWS durch die Granularität optimal strukturiert ist, bietet die Ablage und Einspeisung von Messdaten sowohl die Grundlage eines Live-Monitorings als auch den Grundstein für maschinelles Lernen (ML). Der Datenzugriff via S3-Schnittstelle erleichtert die Entwicklung von eigenen Prognosemodellen mit Informationsmustern (SHIP – Structural Health Information Pattern). Am Beispiel der Heinrichsbrücke Bamberg wird die praktische intelligente Umsetzung des Bauwerksmonitorings inkl. VWS mit Informationsmustern und ML gezeigt.
Air-coupled ultrasonic (ACU) testing has proven to be a valuable method for increasing the speed in non-destructive ultrasonic testing and the investigation of sensitive specimens. A major obstacle to implementing ACU methods is the significant signal power loss at the air–specimen and transducer–air interfaces. The loss between transducer and air can be eliminated by using recently developed fluidic transducers. These transducers use pressurized air and a natural flow instability to generate high sound power signals. Due to this self-excited flow instability, the individual pulses are dissimilar in length, amplitude, and phase. These amplitude and angle modulated pulses offer the great opportunity to further increase the signal-to-noise ratio with pulse compression methods.
In practice, multi-input multi-output (MIMO) setups reduce the time required to scan the specimen surface, but demand high pulse discriminability. By applying envelope removal techniques to the individual pulses, the pulse discriminability is increased allowing only the remaining phase information to be targeted for analysis. Finally, semi-synthetic experiments are presented to verify the applicability of the envelope removal method and highlight the suitability of the fluidic transducer for MIMO setups.
This data article presents characteristic acoustic and flow data of a fluidic ultrasonic transducer as well as acoustic data of a commercial piezoelectric ultrasonic transducer used in non-destructive testing for civil engineering. The flow data has been acquired using hot-wire anemometry and a Pitot tube. The three-dimensional acoustic data of both devices has been acquired using a calibrated microphone. The distribution of characteristic acoustic properties of both transducers are extracted and given in addition to the raw data. The data presented in the article will be a valuable source for reference and validation, both for developing fluidic and alternate ultrasound generation technologies. Furthermore, they will give additional insight into the acoustic-flow interaction phenomena of high speed switching devices. This article is accompanying the paper Experimental Analysis of the Acoustic Field of an Ultrasonic Pulse Induced by a Fluidic Switch (Bühling et al., 2021) published in The Journal of the Acoustical Society of America, where the data is interpreted in detail and the rationale for characteristic sound properties of the fluidic transducer are given.
Making optimal decisions about the reliability of existing structures requires that the information used in assessment adequately represents the properties and the condition of the structures. The knowledge gap regarding a structure to be assessed can be successively filled by individually purposeful observations on site. This paper gives an overview of an approach for utilizing nondestructively gathered measurement results in reliability assessment of existing structures. An essential part of measurement-based stochastic modeling of basic variables is the calculation of measurement uncertainties, which serves to establish confidence in measurement, to ensure the comparability of unambiguously expressed measurement results, and to quantify the quality of the measured information. Regarding the current discourse on how to treat information collected on-site in the context of assessment, the authors recommend that measurement uncertainty becomes an uncertainty component mandatorily to be represented in measurement-based stochastic models. The main steps of the proposed concept are presented, and the advantages of its application are emphasized by means of a prestressed concrete bridge as case study. The bridge is assessed regarding the serviceability limit state decompression using ultrasonic and radar data measured at the structure.
Post-tensioning systems provide safe and efficient construction solutions for long span bridges. Despite the improved grouting practices over the past decade, existing post-tensioning systems may have significant amount of grout defects, which could lead to corrosion of the strands. Condition assessment of post-tensioning systems is necessary to allow bridge owners to take timely, proactive actions to mitigate or prevent further Deterioration and unanticipated tendon failures. A detailed experimental study conducted to assess the performance of nondestructive evaluation techniques in detecting grout defects within internal tendons is presented herein.
Nondestructive evaluation techniques that include Ground Penetrating Radar, Impact Echo, Ultrasonic Tomography, and Ultrasonic Echo are evaluated in terms of detecting the location and severity of fabricated grout defects in a full-scale post-tensioned U-girder mock-up specimen. While Ground Penetrating Radar can identify the location and profile of the internal tendons, particularly metal ducts due to strong reflections, this method did not provide any information about the defect conditions within the tendon. Both Impact Echo and Ultrasonic Echo techniques are effective in identifying the Location of grout defects, but could not differentiate between water, void, or compromised grout conditions. The study clearly demonstrates the need for NDE techniques that are applicable to anchorage regions, and that are capable of estimating the severity and nature of grout defects in internal tendons.
Gegenüber dem Neubauentwurf können bei der Bewertung von bestehender Bausubstanz Sicherheitsreserven genutzt werden, da Unsicherheiten, die beim Bau auftreten können, besser bekannt oder nicht mehr vorhanden sind. Können solche Unsicherheiten genauer bewertet werden, z. B. durch die Feststellung der genauen Lage der Spannglieder bei einer Spannbetonbrücke, so können Sicherheitsbeiwerte reduziert werden, ohne dass es dabei zu Auswirkungen auf das normativ festgelegte Zuverlässigkeitsniveau kommt. Mittlerweile sind Prüfmethoden an Bauwerken wirtschaftlich einsetzbar und auch so leistungsfähig, dass die für die Tragfähigkeit und Gebrauchstauglichkeit wesentlichen Parameter identifiziert werden können. Ein wesentlicher Punkt ist hierbei die Integration derartiger Messergebnisse in Rechenmodelle, die für die Nachrechnung des Bauwerks verwendet werden. Dies können sowohl semiprobabilistische Rechenmodelle als auch vollprobabilistische Modelle sein. Bei semiprobabilistischen Methoden können aus den Messergebnissen Teilsicherheitsbeiwerte berechnet und abgeleitet werden, die dann in den bekannten Nachweisformaten gemäß den Eurocodes und der Nachrechnungsrichtlinie berücksichtigt werden. Bei vollprobabilistischen Nachweisen können die Messdaten in Form von Verteilungsdichtefunktionen mit gemessenen Variationskoeffizienten direkt in das Rechenmodell eingehen. In einer dreiteiligen Aufsatzreihe werden die Messverfahren und die Nutzung der Ergebnisse bei der Nachrechnung vorgestellt. Der vorliegende Teil 1 zeigt die Möglichkeiten des Einsatzes von zerstörungsfreien Prüfverfahren und bewertet deren Leistungsfähigkeit. Messen heißt wissen. Dieses Wissen spiegelt die Realität wider und soll den Tragwerksplaner bei der Entscheidungsfindung über die Sicherheit und Zuverlässigkeit von Bestandsbauwerken unterstützen.