Filtern
Dokumenttyp
Schlagworte
- High resolution (3)
- SyXRD (3)
- Cement hydration (2)
- In-situ (2)
- Sulfate attack (2)
- Cement paste (1)
- Colloidal suspension (1)
- Colloidal suspensions (1)
- Comparison (1)
- Concrete (1)
Cementitious materials, in particular concrete, are durable materials if prepared appropriately and the Service life of concrete structures is now often required to last 120 years or more. Concrete durability depends strongly on intrinsic (e.g. composition, porosity) and exterior factors (e.g. moisture condition and composition, frost cycles, load pattem). Deleterious actions leading to concrete degradation are often created by the environment. Extemal sulfate attack is one of the more spectacular damage scenarios for concrete structures caused by the ingress of sulfate ions into the pore System of the material and successive formation of expanding phases. Though in recent years well studied there are still many questions remaining conceming the mechanisms of sulfate attack. In particular over the last ten years, with the increased utilization of blended cements, new questions arose concerning the sulfate resistance of those binder Systems. In the presented study therefore a method was developed to analyze the changes of the phase composition within the micro structure due to sulfate attack. The analytical method was based on pX-Ray diffraction (pXRD) using Synchrotron radiation in Debye-Scherrer (transmission) geometry. The spatial resolution of the method is ca. 10 pm and allows the characterization of phase transformations in the wake of damaging processes in more detail compared to other techniques. Furthermore, the experimental setup provides the possibility for analyzing the phase assemblage of a given sample without destroying the micro structure. This is possible because the specimens for phase analysis consists of thick sections, which can be used for further microscopic analysis of the micro structure and micro chemistry (e.g. by SEM-EDX). Samples containing supplementary cementitious materials were measured in comparison and to reconstruct the influence of the degradation process in detail. Additionally, reaction ffonts within the samples were localized by micro x-ray fluorescence analysis (MXRF).
Höchst dynamische Hydratationsprozesse in den ersten Sekunden bei der Entstehung eines Bauwerkes lassen sich mithilfe von Synchrotron-Röntgenbeugung mit einer sehr hohen Zeitauflösung nachverfolgen. Der Schwerpunkt lag dabei auf der Beeinflussung der Bildung erster kristalliner Hydratationsprodukte während des Frühstadiums der Zementhydratation.
Setting cement: Highly dynamic hydration processes that occur during the first seconds of cement hydration were studied by time-resolved synchrotron X-ray diffraction. Polycarboxylate ether additives were found to influence the formation of the initial crystalline hydration products on a molecular level.
Spatially resolved analysis of complex multi-phase systems can be validated through different analytical methods. This study compares investigations by scanning electron microscopy coupled with energy dispersive X-ray fluorescence analysis and high resolution X-ray diffraction. The studied sulfate attacked cement paste containing fly ashes consists of different interacting crystalline and amorphous phases. The complementary methods revealed in detail changes in phase composition due to the chemical attack. The advantages and disadvantages of both methods are discussed and suggestions are given for combining them with additional methods to maximize the information content.
Deciphering the sulfate attack of cementitious materials by high-resolution micro-x-ray diffraction
(2011)
The durability of cementitious materials depends, among others, on their resistance against chemical attack during the service life of a building. Here, we present an approach to analyze changes in the phase composition due to chemical attack in the form of sulfate ingress within the microstructure. Micro-X-ray (µX-ray) diffraction using synchrotron radiation in Debye–Scherrer (transmission) geometry allowed a spatial resolution of 10 µm. Phase transformations in the wake of damaging processes were observed in a detailed high-resolution imaging study. In comparison, samples containing supplementary cementitious materials were investigated and used to reconstruct the influence of different degeneration processes in detail. Additionally, reaction fronts within the bulk were localized by micro-X-ray fluorescence analysis. The experimental setup provided the possibility for analyzing the phase assemblage of a given sample without destroying the microstructure. The specimens for phase analysis are thick sections of the primary material and can be used for further microscopic analysis of the microstructure and microchemistry, e.g., scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM–EDX) or Raman spectroscopy.